Evaluation of image quality of personal ultrasound imager: Comparison with the conventional machine

被引:0
作者
Wen Y.L. [1 ,3 ]
Kudo M. [1 ]
Maekawa K. [2 ]
Kawasaki T. [1 ]
Chung H. [1 ]
Minami Y. [1 ]
Suetomi Y. [1 ]
Onda H. [1 ]
Kitano M. [1 ]
Matsui S. [1 ]
Eguchi M. [2 ]
Kuwaguchi A. [2 ]
Kawabata K. [2 ]
机构
[1] Department of Gastroenterology and Hepatology, Kinki University School of Medicine, Osaka-Sayama 589-8511
[2] Abdominal Ultrasound Unit, Kinki University School of Medicine, Osaka-Sayama 589-8511
[3] Department of Ultrasound, Sun Yut-Sen University of Medical Science Memorial Hospital, Guangzhou 510120
关键词
Directional power Doppler imaging; Image quality; Personal ultrasound imager (PUI); Power Doppler imaging; Ultrasound;
D O I
10.1007/BF02481438
中图分类号
学科分类号
摘要
Objective: To determine if the image quality of a personal ultrasound imager (PUI) is as good as that of a conventional machine (CM). Materials and Methods: Ninety patients were studied by the same operator using both the PUI and CM. The quality of the B-mode images obtained from these patients was scored 0, 1, or 2, defined as poor, fair, or good, respectively. Liver-tumor vascularity depicted by power Doppler imaging (PDI) and directional PDI (DPDI) was classified as 0, no blood signal; 1, dot-like blood signal within the tumor; 2, mild blood-flow signal within the tumor; and 3, abundant blood-flow signal within the tumor. Results: The mean score of PUI and CM B-mode image quality was 7.47±0.92 and 7.54±0.99 (mean±SD), respectively (p=0.531). On PDI, grade of vascularity of the liver tumors determined with the PUI was 4.44 and 4.68 in those determined with the CM (p=0.78). On DPDI, tumor vascularity was 3.12 when scored by the PUI and 4.29 when scored with the CM (p=0.03). The qualities of images acquired by the PUI and CM were significantly correlated. Conclusion: The quality of B-mode images acquired using the PUI and CM are statistically the same, and they share a similar ability to detect intratumoral blood-flow signals on PDI. Because of its extreme portability, the PUI is expected to become a valuable diagnostic tool in the clinic.
引用
收藏
页码:41 / 46
页数:5
相关论文
共 13 条
[1]  
Takayasu K., Moriyama N., Muramatsu Y., Et al., The diagnosis of small hepatocellular carcinomas: Efficacy of various imaging procedures in 100 patients, AJR, 155, pp. 49-54, (1990)
[2]  
Choi B.I., Kim T.K., Han J.K., Et al., Vascularity of hepatocellular carcinoma: Assessment with contrast-enhanced second-harmonic versus conventional power Doppler US, Radiology, 214, pp. 381-386, (2000)
[3]  
Kim T.K., Choi B.I., Han J.K., Et al., Hepatic tumors: Contrast agent-enhanced patterns with pulse-inversion harmonic US, Radiology, 216, pp. 411-417, (2000)
[4]  
Bruce C.J., Spittell P.C., Montgomery S.C., Et al., Personal ultrasound imager: Abdominal aortic aneurysm screening, J Am Soc Echocardiogr, pp. 674-679, (2000)
[5]  
Pritchett A.M., Bruce C.J., Bailey K.R., Et al., Personal ultrasound imager: Extension of the cardiovascular physical examination, J Am Soc Echocardiogr, 601, (2000)
[6]  
Wherry D., Potential of a hand-held ultrasound in assessment of the injured patient, Cardiovasc Surg, 6, pp. 569-572, (1998)
[7]  
Joseph A.E.A., Saverymuttu S.H., Al-Sam S., Et al., Comparison of liver histology with ultrasonography in assessing diffuse parenchymal liver disease, Clin Radiol, 43, pp. 26-31, (1991)
[8]  
Martinoli C., Derchi L.E., Rizzatto G., Et al., Power Doppler sonography: General principles, clinical applications, and future prospects, Eur Radiol, 8, pp. 1224-1235, (1998)
[9]  
Lencioni R., Pinto F., Armillotta N., Et al., Assessment of tumor vascularity in hepatocellular carcinoma: Comparison of power Doppler US and color Doppler US, Radiology, 201, pp. 353-358, (1996)
[10]  
Rubin J.M., Bude R.O., Carson P.L., Et al., Power Doppler US: A potentially useful alternative to mean frequency-based color Doppler US, Radiology, 190, pp. 853-856, (1994)