Non-linear separation of pressure, velocity and wave intensity into forward and backward components

被引:0
作者
Jonathan P. Mynard
Malcolm R. Davidson
Daniel J. Penny
Joseph J. Smolich
机构
[1] University of Melbourne,Heart Research Group, Murdoch Childrens Research Institute, Department of Paediatrics
[2] University of Melbourne,Department of Chemical and Biomolecular Engineering
[3] University of Toronto,Biomedical Simulation Laboratory
来源
Medical & Biological Engineering & Computing | 2012年 / 50卷
关键词
Wave intensity analysis; Arterial haemodynamics; Wave separation; Wave speed;
D O I
暂无
中图分类号
学科分类号
摘要
Separating pressure, flow/velocity and wave intensity signals into forward and backward components provide insights about arterial wave propagation and reflection. A linear wave separation is normally used, but ignores the pressure-dependence of wave speed. While a non-linear separation could incorporate this pressure-dependence, no such method exists for wave intensity decomposition. Moreover, although linear separation errors for pressure (5–10 %) have been quantified previously, errors for velocity and wave intensity have not. Accordingly, we describe a non-linear wave separation technique based on the method of characteristics. Data from a computer model suggest that the percentage linear separation errors for velocity and wave intensity are approximately one-half and twice that for pressure, respectively. Although comparable to measurement uncertainty in many instances, linear separation errors may become more significant: (1) if wave speed varies substantially over the cardiac cycle, e.g. if pulse pressure or vessel compliance is high, (2) if the degree of wave reflection in the arterial system is large, or (3) if the constant wave speed used for the linear separation is closer to the minimum or maximum pressure-dependent value rather than the mean. Consideration of linear separation errors may therefore be important in some physiological settings.
引用
收藏
页码:641 / 648
页数:7
相关论文
共 62 条
  • [1] Alastruey J(2009)Analysing the pattern of pulse waves in arterial networks: a time-domain study J Eng Math 64 331-351
  • [2] Parker K(2010)Noninvasive evaluation of left ventricular afterload. Part 2: arterial pressure–flow and pressure–volume relations in humans Hypertension 56 563-570
  • [3] Peiró J(1945)The determination of the propagation velocity of the arterial pulse wave Am J Physiol 144 521-535
  • [4] Sherwin S(2010)Noninvasive assessment of arterial stiffness should discriminate between systolic and diastolic pressure ranges Hypertension 55 124-130
  • [5] Chirinos JA(1973)Influence of flow and pressure on wave propagation in the canine aorta Circ Res 32 524-529
  • [6] Segers P(2001)Determination of wave speed and wave separation in the arteries J Biomech 34 1145-1155
  • [7] Hamilton WF(1979)The calculation of forward and backward waves in the arterial system Med Biol Eng Comput 17 130-130
  • [8] Remington JW(1986)Time domain resolution of forward and reflected waves in the aorta IEEE Trans Biomed Eng 33 783-785
  • [9] Dow P(2008)A 1D arterial blood flow model incorporating ventricular pressure, aortic valve and regional coronary flow using the locally conservative Galerkin (LCG) method Comm Num Meth Eng 24 367-417
  • [10] Hermeling E(2008)Wave intensity amplification and attenuation in non-linear flow: implications for the calculation of local reflection coefficients J Biomech 41 3314-3321