Toward totally endoscopic coronary artery surgery

被引:0
作者
R. H. J. Trimlett
A. C. De Souza
A. S. Coonar
K. M. Jurgens
R. Kuenzler
J. R. Pepper
机构
[1] Royal Brompton Hospital,Department of Cardiothoracic Surgery
[2] Sydney Street,undefined
[3] London,undefined
来源
Surgical Endoscopy And Other Interventional Techniques | 2004年 / 18卷
关键词
Cardiothoracic surgery; Training; Endoscopy; Robotics;
D O I
暂无
中图分类号
学科分类号
摘要
Background: Here we explore a method of using robotics to reduce morbidity and mortality in conventional coronary surgery. Methods: Using a robotic surgical system two surgeons completed five steps: (1) 80 synthetic suture exercises; (2) 76 left internal thoracic artery to left anterior descending (LIMA-to-LAD) on porcine hearts; (3) cadaveric port placement for assessing optimal access; (4) endoscopic stabilization in the live porcine model; and, finally (5) eight clinical LIMA-to-LADs performed robotically. Results: After 70 hours training, mean dry lab times fell from 7.0 and 5.8 min to 5.7 and 5.1 min in the two surgeonstab series. Wet lab times fell from 40.1 and 28.5 min to 28.8 and 19.2 min. In the clinical series of eight patients there were no mortalities; all had uncomplicated postoperative recovery and all were angina free at 6-week follow-up. Conclusion: The learning curve for robotic training is short, and reproducible results can be achieved clinically, after appropriate training, resulting in real patient benefit.
引用
收藏
页码:319 / 322
页数:3
相关论文
共 19 条
[1]  
Favorolo RG(1998)Critical analysis of coronary artery bypass graft surgery: a 30-year journey. J AM Coll Cardiol 31 1B-63B
[2]  
Jansen EWL(1998)Coronary artery bypass grafting without cardiopulmonary bypass using the Octopus method: results in the first 100 patients. J Thorac Cardiovasc Surg 116 60-67
[3]  
Borst C(1998)Randomised trial of laparoscopic versus open cholecystectomy for acute and gangrenous cholecystitis. Lancet 351 321-325
[4]  
Lahpor JR(1999)Effect of coronary occlusion on left ventricular function with and without collateral supply during beating heart surgery. Heart 81 285-291
[5]  
Kiviluoto T(1997)Initial experience using an intraluminal shunt during revascularisation of the beating heart. Ann Thorac Surg 63 1742-1747
[6]  
Siren J(1997)Safe and effective method of stabilisation for coronary artery bypass grafting on the beating heart. Ann Thorac Surg 63 988-992
[7]  
Luukkonen P(1999)Beating heart endoscopic coronary artery surgery. Lancet 254 2131-2132
[8]  
Kivilaakso E(undefined)undefined undefined undefined undefined-undefined
[9]  
Koh TW(undefined)undefined undefined undefined undefined-undefined