Ultrasound biomicroscopy findings of 25 G Transconjuctival sutureless (TSV) and conventional (20G) pars plana sclerotomy in the same patient

被引:33
作者
Keshavamurthy R. [1 ]
Venkatesh P. [1 ]
Garg S. [1 ]
机构
[1] Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi
关键词
Proliferative Diabetic Retinopathy; Vitreous Hemorrhage; Ultrasound Biomicroscopy; Transconjunctival Sutureless Vitrectomy; Sclerotomy Site;
D O I
10.1186/1471-2415-6-7
中图分类号
学科分类号
摘要
Background: Transconjunctival Sutureless Vitrectomy (TSV) is a recent advancement in vitreo-retinal surgical techniques involving the use of 25 G instruments through self-sealing sclerotomies. It has been hypothesized that there may be less chance of vitreous and retinal herniation in the scleral wound as compared to conventional sclerotomy incision. However there are no reports on differences in 20 gauge and 25 gauge sclerotomies using ultrasound biomicroscopy (UBM). We report herein the differences in sclerotomies undertaken with 20 gauge (G) and 25 gauge instruments in the same patient. Case presentation: Ultrasound biomicroscopy of the sclerotomy sites was done in the same patient in whom both 20 G and 25 G sclerotomies had to be constructed during pars plana vitrectomy and the differences were studied. On day 2, we observed a wide gape at the site that had been enlarged using a 20G MVR blade. In contrast, the other two sites made transconjunctivally using the 25G trocar showed only a mild gape. Significant gape continued to persist at the subsequent evaluations on day 7 and day 14 only at the port, which had been enlarged. Conclusion: Healing of a 25 G sclerotomy is expectedly quite rapid, with inability to detect the site of sclerotomy in a short duration of 2 weeks post-operatively. This is as opposed to conventional sclerotomies, which might take up to 6-8 weeks post-operatively for complete opposition. © 2006 Keshavamurthy et al; licensee BioMed Central Ltd.
引用
收藏
页数:4
相关论文
共 7 条
  • [1] Fujii G.Y., De Juan Jr. E., Humayun M.S., Chang T.S., Pieramici D.J., Barnes A., Kent D., Initial experience using the tranconjunctival sutureless vitrectomy system for vitreoretinal surgery, Ophthalmology, 109, 10, pp. 1814-1820, (2002)
  • [2] Kwok A.K., Tham C.C., Loo A.V., Fan D.S., Lam D.S., Ultrasound biomicroscopy of conventional and sutureless pars plana sclerotomies: A comparative and longitudinal study, Am J Ophthalmol, 132, 2, pp. 172-177, (2001)
  • [3] Boker T., Spitznas M., Ultrasound biomicroscopy for examination of the sclerotomy sites after parsplana vitrectomy, Am J Ophthalmol, 118, pp. 813-815, (1994)
  • [4] Bhende M., Agraharam S.G., Gopal L., Sumasri K., Sukumar B., George J., Sharma T., Shanmugam M.P., Bhende P.S., Shetty N.S., Agarwal R.N., Despande D.A., Ultrasound biomicroscopy of sclerotomy sites after pars plana vitrectomy for diabetic vitreous hemorrhage, Ophthalmology, 107, pp. 1729-1736, (2000)
  • [5] Arakawa A., Tamai M., Ultrasound biomicroscopic analysis of anterior proliferative vitreoretinopathy, Am J Ophthalmol, 126, pp. 838-839, (1998)
  • [6] Minamoto A., Nakano K.E., Tanimoto S., Mizote H., Takeda Y., Ultrasound biomicroscopy in the diagnosis of persistent hypotony after vitrectomy, Am J Ophthalmol, 123, pp. 711-713, (1997)
  • [7] Tardif Y.M., Schepens C.L., Tolentine F.L., Vitreous surgery: Complications from sclerotomy in 89 consecutive cases, Arch Ophthalmol, 95, pp. 229-234, (1977)