Comparative analysis of despeckling filters for continuous wave Doppler images

被引:1
|
作者
Biradar N. [1 ]
Dewal M.L. [1 ]
Rohit M.K. [2 ]
机构
[1] Indian Institute of Technology Roorkee, Roorkee
[2] Post Graduate Institute of Medical Education and Research, Chandigarh
来源
Biomed. Eng. Lett. | / 1卷 / 33-44期
关键词
Despeckling filters; Doppler echocardiography; Edge preservation; Speckle noise;
D O I
10.1007/s13534-015-0171-5
中图分类号
学科分类号
摘要
Purpose: The problems of speckle noise, low contrast, and other artifacts in continuous wave Doppler (CWD) based echocardiographic images are identical to the issues prevailing in the B-mode images. The median filter and Gaussian low pass filter are more commonly used for reduction of noise in CWD images. The applications of state-of-the-art despeckling filters and their impact on delineation are not extensively analyzed using CW Doppler images.Methods: This paper analyses the noise reduction, edge and structure preservation characteristics of ten filters for CWD images in terms of 15 image quality metrics along with visual quality assessment. Further, three segmentation techniques were analyzed using original and noisy CWD images. Three existing delineation techniques are modified for tracing the outer boundaries of CWD spectrum. The Gaussian filter used reaction-diffusion based active contour and thresholding based segmentation techniques are replaced by despeckling filter based on anisotropic diffusion and local statistics.Results: The noise is suppressed with edges and structure well preserved on application of filters such as speckle reducing anisotropic diffusion filter and local statics (mean and variance) based filter. The number of iterations required in complete boundary tracing is reduced on replacing the Gaussian filter with despeckling filter in reaction diffusion based active contour segmentation.Conclusions: The analysis reveals that the despeckling techniques enhance the visual quality of images and play a vital role in delineation process. The reaction diffusion based active contour embedded with speckle reducing anisotropic diffusion filter results in accurate contouring of the CWD images. © 2015, Korean Society of Medical and Biological Engineering and Springer.
引用
收藏
页码:33 / 44
页数:11
相关论文
共 50 条
  • [21] A COMPARATIVE-STUDY OF CONTINUOUS-WAVE AND PULSED-WAVE DOPPLER VELOCIMETRY IN FETAL AND UTEROPLACENTAL CIRCULATION
    CHAN, FY
    PUN, TC
    LEE, CP
    LAM, C
    KHOO, J
    LEONG, L
    JOURNAL OF ULTRASOUND IN MEDICINE, 1991, 10 (05) : 277 - 280
  • [22] Performance evaluation of linear and nonlinear filters for despeckling B mode foetal heart ultrasound images
    Sriraam, N.
    Prabha, V. Punya
    Sushma, T. V.
    Suresh, S.
    IMAGING SCIENCE JOURNAL, 2024, 72 (08): : 979 - 996
  • [23] An Approach for Despeckling a Sequence of Ultrasound Images Based on Statistical Analysis
    Sagheer S.V.M.
    George S.N.
    Sensing and Imaging, 2017, 18 (1):
  • [24] A COMPARATIVE-STUDY OF CONTINUOUS WAVE VS PULSED DOPPLER ULTRASOUND IN ASSESSING AORTIC REGURGITATION
    POLLET, E
    METZ, D
    JOLLY, D
    CHAPOUTOT, L
    GANDON, T
    ELAERTS, J
    BAJOLET, A
    ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 1989, 38 (01): : 1 - 6
  • [25] Automated Delineation of Doppler Echocardiographic images using Texture Filters
    Biradar, Nagashettappa
    Dewal, M. L.
    Rohit, Manoj Kumar
    2015 2ND INTERNATIONAL CONFERENCE ON COMPUTING FOR SUSTAINABLE GLOBAL DEVELOPMENT (INDIACOM), 2015, : 1903 - 1907
  • [26] Micro-Doppler analysis of multiple frequency continuous wave radar signatures
    Anderson, Michael G.
    Rogers, Robert L.
    RADAR SENSOR TECHNOLOGY XI, 2007, 6547
  • [27] Grading of mitral regurgitation based on intensity analysis of the continuous wave Doppler signal
    El Haddad, Milad
    De Backer, Tine
    De Buyzere, Marc
    Devos, Daniel
    Swillens, Abigail
    Segers, Patrick
    Timmermans, Frank
    HEART, 2017, 103 (03) : 190 - 197
  • [28] Comparative Analysis of Wave Distribution in Layered and Heterogeneous Continuous Media
    Kraus, A. E.
    Shabalin, I. I.
    INTERNATIONAL CONFERENCE ON THE METHODS OF AEROPHYSICAL RESEARCH (ICMAR 2018), 2018, 2027
  • [29] Doppler continuous wave scanning acoustic microscope
    Titov, SA
    Maev, RG
    1997 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 & 2, 1997, : 713 - 718
  • [30] RELIABILITY OF CONTINUOUS-WAVE DOPPLER PROBES
    LONG, JW
    STEVENS, R
    LICHTI, E
    SILVER, D
    JOURNAL OF VASCULAR SURGERY, 1987, 5 (04) : 558 - 565