Field study of the composition of greywater and comparison of microbiological indicators of water quality in on-site systems

被引:0
作者
Margaret Leonard
Brent Gilpin
Beth Robson
Katrina Wall
机构
[1] Ara Institute of Canterbury,
[2] Institute of Environmental Science and Research,undefined
[3] Health Protection NSW,undefined
来源
Environmental Monitoring and Assessment | 2016年 / 188卷
关键词
Greywater; Microbial indicators; Water reuse; Treatment;
D O I
暂无
中图分类号
学科分类号
摘要
Thirty on-site greywater systems were sampled to determine greywater characteristics and practices in the field. Kitchen greywater was present at eight sites and urine was included at seven sites. These non-traditional sources resulted in significantly higher concentrations of enterococci and 5-day biochemical oxygen demand (BOD5) in greywater. Even with the removal of these sources, the concentrations of microbial indicators indicated high levels of contamination could occur across all greywater sources, including “light” greywater. Using multiple microbial indicators showed that all samples had the potential for faecal contamination. Bacteroidales markers were confirmed in treated greywater and in each greywater source, highlighting the potential for human faecal contamination. Although Escherichia coli was absent in treated greywater recycled to the house, other microbial indicators were present; hence, caution is required in using E. coli concentrations as the sole indicator of microbiological water quality. High BOD5 or total suspended solid concentrations exceeded the levels recommended for effective disinfection. Subsurface irrigation, which is assumed to provide a five-log reduction in exposure, is a suitable reuse option for non-disinfected greywater. Only half the occupants had a good understanding of their greywater systems and 25 % of systems were poorly maintained. Elevated microbial indicator contamination of greywater sludge is a potential hazard during maintenance.
引用
收藏
相关论文
共 230 条
  • [11] O’Toole J(2005)Unravelling Trends in Parasitology 21 430-437
  • [12] Sinclair MI(2001) and Journal of Environmental Science and Health A36 395-401
  • [13] Leder K(2011) epidemiology Water, Air, & Soil Pollution 215 31-42
  • [14] Malawaraarachchi M(2005)Chemical and microbial characterization of graywater Water Science and Technology 51 163-169
  • [15] Hamilton AJ(2007)Bathroom greywater characterization and potential treatments for reuse Water Research 41 3553-3560
  • [16] Beck SE(2013)Effluent quality from 200 on-site sewage systems: design values for guidelines Journal of Water and Health 11 397-409
  • [17] Rodríguez RA(2004)A PCR marker for detection in surface waters of faecal pollution derived from ducks Applied and Environmental Microbiology 70 5695-5697
  • [18] Salveson A(2002)Distinguishing human and possum faeces using PCR markers Urban Water 4 85-104
  • [19] Goel N(2006)Rapid estimation of numbers of fecal Bacteroidetes by use of a quantitative PCR assay for 16S rRNA genes Desalination 190 221-234
  • [20] Rhodes S(2005)Characteristics of grey wastewater Water Science and Technology 51 187-194