Amperometric detection of nitric oxide using a glassy carbon electrode modified with gold nanoparticles incorporated into a nanohybrid composed of reduced graphene oxide and Nafion

被引:0
|
作者
Norazriena Yusoff
Perumal Rameshkumar
Muhammad Mehmood Shahid
Sheng-Tung Huang
Nay Ming Huang
机构
[1] University of Malaya,Low Dimensional Materials Research Centre, Department of Physics, Faculty of Science
[2] Kalasalingam University (Kalasalingam Academy of Research and Education),Department of Chemistry
[3] National Taipei University of Technology,Institute of Biochemical and Biomedical Engineering
[4] Xiamen University of Malaysia,Faculty of Engineering
来源
Microchimica Acta | 2017年 / 184卷
关键词
Graphene materials; Metal nanoparticles; Electrochemical sensor; Modified electrode; Electroanalysis; Biomolecules;
D O I
暂无
中图分类号
学科分类号
摘要
The authors show that the electrocatalytic performance toward the detection of nitric oxide (NO) can be enhanced by making use of gold nanoparticles (AuNP) in a matrix consisting of reduced graphene oxide and Nafion (rGO-Nf). The rGO-Nf@Au nanohybrid was synthesized via a hydrothermal method. The spherical AuNP have diameters in the range from 50 to 200 nm as proven by field emission scanning electron microscopy (FESEM). A glassy carbon electrode (GCE) modified with the nanohybrid displays excellent electrocatalytic activity towards NO oxidation compared to other kinds of modified electrodes. Best operated at a voltage of +0.8 V (vs. SCE), the amperometric response was linear in the 1 μM to 0.16 mM nitrite concentration range, with 0.5 μM detection limit (at an S/N ratio of 3). The high surface area of the AuNP along with the synergistic effect of AuNP and rGO-Nf film on the signal current is believed to cause the enhanced electrocatalytic activity of the nanohybrid. The sensor is not interfered by dopamine (DA), ascorbic acid (AA), uric acid (UA), glucose, urea, and NaCl even in 5-fold higher concentrations. In our perception, the rGO-Nf@Au modified electrode is a promising tool for highly sensitive and selective amperometric sensing of NO.
引用
收藏
页码:3291 / 3299
页数:8
相关论文
共 50 条
  • [41] A Glassy Carbon Electrode Modified with Electrochemically Reduced Graphene Oxide/Gold Nanoparticles-Chitosan Composite Film for Sensitive Determination of Uric Acid
    Wu Ling
    Cao Zhong
    Song Tian-Ming
    Song, Cheng
    Xie Jing-Lei
    He Jing-Lin
    Xiao Zhong-Liang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (11) : 1656 - 1660
  • [42] Determination of melamine in food contact materials using an electrode modified with gold nanoparticles and reduced graphene oxide
    Chen, Ningning
    Cheng, Yuxiao
    Li, Chen
    Zhang, Cuiling
    Zhao, Kai
    Xian, Yuezhong
    MICROCHIMICA ACTA, 2015, 182 (11-12) : 1967 - 1975
  • [43] Sensitive detection of dopamine using a platinum microelectrode modified by reduced graphene oxide and gold nanoparticles
    Chen, Xing
    Chen, Jing
    Dong, Hao
    Yu, Qiwen
    Zhang, Shaomin
    Chen, Hang
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 848
  • [44] Highly improved sensing of dopamine by using glassy carbon electrode modified with MnO2, graphene oxide, carbon nanotubes and gold nanoparticles
    Dejiang Rao
    Xinjin Zhang
    Qinglin Sheng
    Jianbin Zheng
    Microchimica Acta, 2016, 183 : 2597 - 2604
  • [45] Binary Metal oxide Adsorbed Graphene Modified Glassy Carbon Electrode for Detection of Riboflavin
    Grace, Arockiajawahar Anancia
    Thillaiarasi, Sukumar
    Dharuman, Venkataraman
    ELECTROANALYSIS, 2021, 33 (04) : 993 - 1006
  • [46] Determination of melamine in food contact materials using an electrode modified with gold nanoparticles and reduced graphene oxide
    Ningning Chen
    Yuxiao Cheng
    Chen Li
    Cuiling Zhang
    Kai Zhao
    Yuezhong Xian
    Microchimica Acta, 2015, 182 : 1967 - 1975
  • [47] Amperometric nonenzymatic determination of glucose via a glassy carbon electrode modified with nickel hydroxide and N-doped reduced graphene oxide
    Zhang, Yuehua
    Lei, Wu
    Wu, Qiuju
    Xia, Xifeng
    Hao, Qingli
    MICROCHIMICA ACTA, 2017, 184 (09) : 3103 - 3111
  • [48] Electrochemical determination of dopamine using a glassy carbon electrode modified with TiN-reduced graphene oxide nanocomposite
    Haldorai, Yuvaraj
    Vilian, A. T. Ezhil
    Rethinasabapathy, Muruganantham
    Huh, Yun Suk
    Han, Young-Kyu
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 247 : 61 - 69
  • [49] Voltammetric determination of caffeic acid byusing aglassy carbon electrode modified with achitosan-protected nanohybrid composed of carbon black and reduced graphene oxide
    Pandian, Kannaiyan
    Soundari, Dhamodaran Mohana
    Showdri, Panneerselvam Rudra
    Kalaiyarasi, Jayaprakash
    Gopinath, Subash C. B.
    MICROCHIMICA ACTA, 2019, 186 (02)
  • [50] Voltammetric determination of hydroquinone, catechol, and resorcinol by using a glassy carbon electrode modified with electrochemically reduced graphene oxide-poly(Eriochrome black T) and gold nanoparticles
    Nusiba Mohammed Modawe Alshik Edris
    Jaafar Abdullah
    Sazlinda Kamaruzaman
    Yusran Sulaiman
    Microchimica Acta, 2019, 186