Beta-blocker therapy is associated with a lower incidence of syncope due to fast ventricular tachycardias among implantable cardioverter-defibrillator patients with left ventricular dysfunction: results from a multicenter study

被引:0
作者
Javier Jiménez-Candil
Ignasi Anguera
Olga Durán
Jesús Hernández
Javier Fernández-Portales
José Luis Moríñigo
Ana Martín
Paolo Dallaglio
Loreto Bravo
Andrea di Marco
Pedro Luis Sánchez
机构
[1] IBSAL-University Hospital,Cardiology Department
[2] School of Medicine,undefined
[3] University of Salamanca,undefined
[4] CIVERCV,undefined
[5] Salamanca,undefined
[6] Hospital Universitari de Bellvitge,undefined
[7] Hospital San Pedro de Alcántara,undefined
来源
Journal of Interventional Cardiac Electrophysiology | 2018年 / 52卷
关键词
Implantable cardiac defibrillator; Ventricular tachycardia; Beta-blocker treatment; Syncope;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:69 / 76
页数:7
相关论文
共 119 条
[1]  
Bardy GH(1997)A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias. The Antiarrhythmics versus Implantable Defibrillators (AVID) Investigators N Engl J Med 337 1576-1583
[2]  
Lee KL(2005)Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure N Engl J Med 352 225-237
[3]  
Mark DB(2002)Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction N Engl J Med 346 877-883
[4]  
Poole JE(2008)Syncope predicts the outcome of cardiomyopathy patients: analysis of the SCD-HeFT study J Am Coll Cardiol 51 1277-1282
[5]  
Packer DL(2014)Syncope in high-risk cardiomyopathy patients with implantable defibrillators: frequency, risk factors, mechanisms, and association with mortality: results from the multicenter automatic defibrillator implantation trial-reduce inappropriate therapy (MADIT-RIT) study Circulation 129 545-552
[6]  
Boineau R(2006)Syncope following cardioverter defibrillator implantation in patients with spontaneous syncopal monomorphic ventricular tachycardia Eur Heart J 27 89-95
[7]  
Moss AJ(1998)Mechanisms of syncope in implantable cardioverter-defibrillator recipients who receive device therapies Am J Cardiol 82 1372-1376
[8]  
Zareba W(2013)Morphology of far-field electrograms and antitachycardia pacing effectiveness among fast ventricular tachycardias occurring in ICD patients: a multicenter study J Cardiovasc Electrophysiol 24 1375-1382
[9]  
Hall WJ(2005)Fast ventricular tachycardias in patients with implantable cardioverter-defibrillators: efficacy and safety of antitachycardia pacing. A prospective and randomized study J Am Coll Cardiol 45 460-461
[10]  
Klein H(2004)Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results Circulation 110 2591-2596