Left Ventricular Assist Devices: Challenges Toward Sustaining Long-Term Patient Care

被引:0
作者
Marianne Schmid Daners
Friedrich Kaufmann
Raffael Amacher
Gregor Ochsner
Markus J. Wilhelm
Aldo Ferrari
Edoardo Mazza
Dimos Poulikakos
Mirko Meboldt
Volkmar Falk
机构
[1] ETH Zurich,Product Development Group Zurich, Department of Mechanical and Process Engineering
[2] German Heart Center Berlin,Wyss Zurich
[3] ETH Zurich and University of Zurich,Institute for Dynamic Systems and Control, Department of Mechanical and Process Engineering
[4] ETH Zurich,Department of Cardiovascular Surgery
[5] University Hospital Zurich and University of Zurich,Laboratory of Thermodynamics in Emerging Technologies, Department of Mechanical and Process Engineering
[6] ETH Zurich,Institute for Mechanical Systems, Department of Mechanical and Process Engineering
[7] ETH Zurich,undefined
[8] Swiss Federal Laboratories for Materials Science and Technology,undefined
[9] EMPA,undefined
来源
Annals of Biomedical Engineering | 2017年 / 45卷
关键词
Adverse events; Heart failure; Cardiac surgery; Surface structure; Hemocompatibility; Fluid dynamics; Implantability; Physiological control;
D O I
暂无
中图分类号
学科分类号
摘要
Over the last few decades, the left ventricular assist device (LVAD) technology has been tremendously improved transitioning from large and noisy paracorporeal volume displacement pumps to small implantable turbodynamic devices with only a single transcutaneous element, the driveline. Nevertheless, there remains a great demand for further improvements to meet the challenge of having a robust and safe device for long-term therapy. Here, we review the state of the art and highlight four key areas of needed improvement targeting long-term, sustainable LVAD function: (1) LVADs available today still have a high risk of thromboembolic and bleeding events that could be addressed by the rational fabrication of novel surface structures and endothelialization approaches aiming at improving the device hemocompatibility. (2) Novel, fluid dynamically optimized pump designs will further reduce blood damage. (3) Infection due to the paracorporeal driveline can be avoided with a transcutaneous energy transmission system that additionally allows for increased freedom of movement. (4) Finally, the lack of pump flow adaptation needs to be encountered with physiological control systems, working collaboratively with biocompatible sensor devices, targeting the adaptation of the LVAD flow to the perfusion requirements of the patient. The interdisciplinary Zurich Heart project investigates these technology gaps paving the way toward LVADs for long-term, sustainable therapy.
引用
收藏
页码:1836 / 1851
页数:15
相关论文
共 757 条
[71]  
Ramesh B(2014)An analysis of pump thrombus events in patients in the heartware advance bridge to transplant and continued access protocol trial J. Heart Lung Transpl. 33 23-583
[72]  
Parry G(2015)HeartMate III, fully magnetically levitated left ventricular assist device for the treatment of advanced heart failure—results from the CE mark trial J. Cardiac Fail. 21 936-229
[73]  
Roysam C(2016)Point-of-care rapid seeding ventricular assist device with blood-derived endothelial cells to create a living antithrombotic coating ASAIO J. 62 447-10
[74]  
Woods A(2013)A novel interface for hybrid mock circulations to evaluate ventricular assist devices IEEE Trans. Biomed. Eng. 60 507-336
[75]  
Robinson-Smith N(2014)A physiological controller for turbodynamic ventricular assist devices based on a measurement of the left ventricular volume Artif. Organs 38 527-840
[76]  
Wrightson N(2017)In vivo evaluation of physiological control algorithms for LVADs based on left ventricular volume or pressure ASAIO J 10 35-527
[77]  
Bottan S(2013)Numerical investigation of the effect of cannula placement on thrombosis Theor. Biol. Med. Modell. 26 219-855
[78]  
Robotti F(2007)Does total implantability reduce infection with the use of a left ventricular assist device? The LionHeart experience in Europe J. Heart Lung Transpl. 39 1-376
[79]  
Jayathissa P(2009)Current mechanical circulatory support devices for end stage heart failure Korean Circ. J. 31 329-150
[80]  
Hegglin A(2016)Creating adequate pulsatility with a continuous flow left ventricular assist device: just do it! Curr. Opin. Cardiol. 86 832-1079