Left Ventricular Assist Devices: Challenges Toward Sustaining Long-Term Patient Care

被引:0
作者
Marianne Schmid Daners
Friedrich Kaufmann
Raffael Amacher
Gregor Ochsner
Markus J. Wilhelm
Aldo Ferrari
Edoardo Mazza
Dimos Poulikakos
Mirko Meboldt
Volkmar Falk
机构
[1] ETH Zurich,Product Development Group Zurich, Department of Mechanical and Process Engineering
[2] German Heart Center Berlin,Wyss Zurich
[3] ETH Zurich and University of Zurich,Institute for Dynamic Systems and Control, Department of Mechanical and Process Engineering
[4] ETH Zurich,Department of Cardiovascular Surgery
[5] University Hospital Zurich and University of Zurich,Laboratory of Thermodynamics in Emerging Technologies, Department of Mechanical and Process Engineering
[6] ETH Zurich,Institute for Mechanical Systems, Department of Mechanical and Process Engineering
[7] ETH Zurich,undefined
[8] Swiss Federal Laboratories for Materials Science and Technology,undefined
[9] EMPA,undefined
来源
Annals of Biomedical Engineering | 2017年 / 45卷
关键词
Adverse events; Heart failure; Cardiac surgery; Surface structure; Hemocompatibility; Fluid dynamics; Implantability; Physiological control;
D O I
暂无
中图分类号
学科分类号
摘要
Over the last few decades, the left ventricular assist device (LVAD) technology has been tremendously improved transitioning from large and noisy paracorporeal volume displacement pumps to small implantable turbodynamic devices with only a single transcutaneous element, the driveline. Nevertheless, there remains a great demand for further improvements to meet the challenge of having a robust and safe device for long-term therapy. Here, we review the state of the art and highlight four key areas of needed improvement targeting long-term, sustainable LVAD function: (1) LVADs available today still have a high risk of thromboembolic and bleeding events that could be addressed by the rational fabrication of novel surface structures and endothelialization approaches aiming at improving the device hemocompatibility. (2) Novel, fluid dynamically optimized pump designs will further reduce blood damage. (3) Infection due to the paracorporeal driveline can be avoided with a transcutaneous energy transmission system that additionally allows for increased freedom of movement. (4) Finally, the lack of pump flow adaptation needs to be encountered with physiological control systems, working collaboratively with biocompatible sensor devices, targeting the adaptation of the LVAD flow to the perfusion requirements of the patient. The interdisciplinary Zurich Heart project investigates these technology gaps paving the way toward LVADs for long-term, sustainable therapy.
引用
收藏
页码:1836 / 1851
页数:15
相关论文
共 757 条
[1]  
Agarwal S(2012)Newer-generation ventricular assist devices Best Pract. Res. Clin. Anaesthesiol. 26 117-130
[2]  
High KM(2015)Hospital readmissions after continuous-flow left ventricular assist device implantation: incidence, causes, and cost analysis Ann. Thorac. Surg. 100 884-889
[3]  
Akhter SA(2011)Berlin Heart EXCOR Pediatric ventricular assist device investigational device exemption study: study design and rationale Am. Heart J. 162 425-435
[4]  
Badami A(2014)Numerical optimal control of turbo dynamic ventricular assist devices Bioengineering 1 22-46
[5]  
Murray M(2013)A robust reference signal generator for synchronized ventricular assist devices IEEE Trans. Biomed. Eng. 60 2174-2183
[6]  
Kohmoto T(2013)Control of ventricular unloading using an electrocardiogram-synchronized Thoratec paracorporeal ventricular assist device J. Thorac. Cardiovasc. Surg. 146 710-717
[7]  
Lozonschi L(2015)Durable mechanical circulatory support versus organ transplantation: past, present, and future Biomed Res Int 2015 849571-305
[8]  
Osaki S(2015)Left ventricular assist device driveline infections: the Achilles’ heel of destination therapy AACN Adv Crit Care 26 300-771
[9]  
Lushaj EB(2008)Physiological control of a rotary blood pump with selectable therapeutic options: control of pulsatility gradient Artif. Organs 32 761-202
[10]  
Almond CS(2014)Implantable physiologic controller for left ventricular assist devices with telemetry capability J. Thorac. Cardiovasc. Surg. 147 192-319