A One-Step Immunoassay for Carbohydrate Antigen 19-9 by Biosensor Based on Imaging Ellipsometry

被引:0
作者
Chenghong Huang
Yanyan Chen
Gang Jin
机构
[1] Chinese Academy of Sciences,Suzhou Institute of Nano
[2] Chinese Academy of Sciences,tech and Nano
[3] Institute of Mechanics,bionics
[4] CAS,Institute of Biophysics
[5] Graduate School of the Chinese Academy of Sciences,Key Laboratory of Microgravity
来源
Annals of Biomedical Engineering | 2011年 / 39卷
关键词
Biosensor; Imaging ellipsometry; Carbohydrate antigen 19-9; Immunoassay;
D O I
暂无
中图分类号
学科分类号
摘要
Cancer markers can offer much more information for developing or developed cancers. Simple and short-time assay of cancer biomarker is essential for clinic diagnosis and management. In this study, a one-step immunoassay for carbohydrate antigen 19-9 (CA19-9) by biosensor based on imaging ellipsometry (BIE) is described and its analysis performances are evaluated. Anti-CA19-9 monoclonal antibody as ligand covalently immobilized on carboxyl-modified silicon substrate and its immobilization concentration concurrently screened. Then, bovine serum albumin (BSA) is used to block for acquisition of sensing layer. The detection linear range is from 15.0 to 120.0 U/mL with a minimum limit of 10.0 U/mL (S/N = 3). The intra-slide and inter-slide reproducibility, expressed as coefficient variation (CV%), are 9.9, 5.9, 5.4% and 9.6, 7.6, 5.3% for 31.9, 57.4, and 99.2 U/mL of CA19-9, respectively. Accuracy determined by spiked-recovery is among 95.1–106.7%. Specificity expressed as cross-reaction rate are all below 5.8% evaluated by three analogous biomarkers alpha-fetoprotein (AFP), carcinoembryonic antigen (CEA), and carbohydrate antigen 242 (CA242). Application of BIE to 25 clinic samples demonstrated that the results are in high correlate with electrochemiluminescent immunoassay (ECLIA, R2 = 0.997). The proposed immunoassay has the potential for clinic application.
引用
收藏
页码:185 / 192
页数:7
相关论文
共 121 条
  • [1] Arwin H(1985)A reflectance method for quantification of immunological reactions on surfaces Anal. Biochem. 145 106-112
  • [2] Lundstrgm I(2001)Dendrimer-activated solid supports for nucleic acid and protein microarrays Chembiochem 2 686-694
  • [3] Benters R(1995)Preperative serum levels of CEA and CA242 in colorectal cancer Br. J. Cancer 71 868-872
  • [4] Niemeyer CM(2007)Optimization of off-null ellipsometry for air/solid interfaces Appl. Opt. 46 8475-8481
  • [5] Wöhrle D(2000)Validation of immunoassays for bioanalysis: a pharmaceutical industry perspective J. Pharm. Biomed. Anal. 21 1249-1273
  • [6] Carpelan-Holmstrom M(2002)Elevated carbohydrate antigen 19-9 levels in a patient with choledocholithiasis Turk. J. Gastroenterol. 13 213-215
  • [7] Haglund C(2009)Biomarkers for early detection and screening in pancreatic cancer J. Pancreas 10 352-356
  • [8] Kuusela P(2008)Development of biosensor based on imaging ellipsometry Phys. Stat. Sol. (a) 205 810-816
  • [9] Jarvinen H(1995)A biosensor concept based on imaging ellipsometry for visualization of biomolecular interactions Anal. Biochem. 232 69-72
  • [10] Roberts P(1996)Imaging ellipsometry revisited: developments for visualization of thin transparent layers on silicon substrates Rev. Sci. Instrum. 67 2930-2936