Determination of iodide ions at poly(3-methylthiophene)-modified electrode by differential pulse stripping voltammetry

被引:0
作者
S. Titretir
G. Erdoğdu
A. E. Karagözler
机构
[1] İnönü University,Department of Chemistry, Faculty of Arts and Sciences
[2] Adnan Menderes University,Department of Chemistry, Faculty of Arts and Sciences
来源
Journal of Analytical Chemistry | 2006年 / 61卷
关键词
Oxidation; Polymer; Precipitation; Gold; Analytical Chemistry;
D O I
暂无
中图分类号
学科分类号
摘要
A voltammetric electrode based on a poly(3-methylthiophene) (PMT) film for the differential pulse stripping voltammetric (DPSV) determination of iodide was developed. Gold electrodes were first coated with PMT, and iodide was then doped into the polymer film by electrochemical oxidation of iodide at 0.75 V. The effects of various electrochemical parameters, such as electroyte type and its pH, deposition potential, deposition time, and precipitation time, were examined. Using DPSV, the PMT electrode was found to be suitable for the measurement of iodide concentrations above 1 × 10−9 M.
引用
收藏
页码:592 / 595
页数:3
相关论文
共 50 条
[31]   Determination of Silver(I) by Differential Pulse Voltammetry Using a Glassy Carbon Electrode Modified with Synthesized N-(2-Aminoethyl)-4,4′-Bipyridine [J].
Radulescu, Maria-Cristina ;
Chira, Ana ;
Radulescu, Medeea ;
Bucur, Bogdan ;
Bucur, Madalina Petruta ;
Radu, Gabriel Lucian .
SENSORS, 2010, 10 (12) :11340-11351
[32]   Electrochemical Behavior of Atorvastatin at Glassy Carbon Electrode and its Direct Determination in Pharmaceutical Preparations by Square Wave and Differential Pulse Voltammetry [J].
Yilmaz, B. ;
Kaban, S. .
INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2016, 78 (03) :360-367
[33]   Electrochemical Investigation of Thiophene on Glassy Carbon Electrode and Quantitative Determination of it in Simulated Oil Solution by Differential Pulse Voltammetry and Amperometry Techniques [J].
Mostafavi, S. Mojtaba ;
Rouhollahi, Ahmad ;
Adibi, Mina ;
Mohajeri, Ali ;
Pashaee, Farshid ;
Pyriaee, Masoumeh .
ASIAN JOURNAL OF CHEMISTRY, 2011, 23 (12) :5356-5360
[34]   Differential pulse voltammetric determination of hexavalent chromium using nickel hexacyanoferrate modified glassy carbon electrode [J].
Dinbore, Wendimagegn T. ;
Dabbo, Wolde C. ;
Washe, Aemayehu P. .
SUSTAINABLE ENVIRONMENT, 2021, 7 (01)
[35]   TRACE MULTIELEMENT DETERMINATIONS IN REACTOR MODERATOR WATER - SIMULTANEOUS DETERMINATION OF COPPER, GOLD, SILVER AND MERCURY USING DIFFERENTIAL-PULSE STRIPPING VOLTAMMETRY [J].
ALMON, AC .
ANALYTICA CHIMICA ACTA, 1991, 249 (02) :447-450
[36]   Differential Pulse Voltammetric Determination of Piroxicam on Lanthanide Ferric Oxide Nanoparticles-Carbon Paste Modified Electrode [J].
Lopes de Macedo, Isaac Yves ;
Alecrim, Morgana Fernandes ;
Garcia, Luane Ferreira ;
de Souza, Aparecido Ribeiro ;
Pio dos Santos, Wallans Tones ;
Gil, Eric de Souza ;
Cubillana-Aguilera, Laura M. ;
Palacios-Santander, Jose Maria .
CURRENT PHARMACEUTICAL ANALYSIS, 2018, 14 (03) :271-276
[37]   A glassy carbon electrode modified with carboxylated diamond nanoparticles for differential pulse voltammetric simultaneous determination of guanine and adenine [J].
Biuck Habibi ;
Mojtaba Jahanbakhshi .
Microchimica Acta, 2016, 183 :2317-2325
[38]   A glassy carbon electrode modified with carboxylated diamond nanoparticles for differential pulse voltammetric simultaneous determination of guanine and adenine [J].
Habibi, Biuck ;
Jahanbakhshi, Mojtaba .
MICROCHIMICA ACTA, 2016, 183 (07) :2317-2325
[39]   Electrochemical determination of iodide by poly(3-aminophenylboronic acid) film electrode at moderately low pH ranges [J].
Ciftci, Hakan ;
Tamer, Ugur .
ANALYTICA CHIMICA ACTA, 2011, 687 (02) :137-140
[40]   Ratiometric Electrochemical Determination of Ascorbic Acid Using a Copper Nanoparticle@Resin Nanosphere (CuNPs@RNS) Modified Glassy Carbon Electrode (GCE) by Differential Pulse Voltammetry (DPV) [J].
Zhang, Jie ;
Fu, Yulin ;
Li, Lin ;
Yan, Liqiang ;
Wu, Xiongzhi ;
Lei, Chenghong .
ANALYTICAL LETTERS, 2023, 56 (16) :2649-2660