Concurrent functional and metabolic assessment of brain tumors using hybrid PET/MR imaging

被引:0
作者
B. Sacconi
R. A. Raad
J. Lee
H. Fine
D. Kondziolka
J. G. Golfinos
J. S. Babb
R. Jain
机构
[1] NYU School of Medicine,Department of Radiology
[2] New York-Presbyterian Hospital,Department of Medicine, Weill Cornell Medical College
[3] NYU School of Medicine,Department of Neurosurgery
来源
Journal of Neuro-Oncology | 2016年 / 127卷
关键词
PET/MR; Perfusion; CBV; FDG; Glioma;
D O I
暂无
中图分类号
学科分类号
摘要
To evaluate diagnostic accuracy of perfusion weighted imaging (PWI) and positron emission tomography (PET) using an integrated PET/MR system in tumor grading as well as in differentiating recurrent tumor from treatment-induced effects (TIE) in brain tumor patients. Twenty patients (Group A: treatment naïve, 9 patients with 16 lesions; Group B: post-therapy, 11 patients with 18 lesions) underwent fluorine 18 (18F) fluorodeoxyglucose (FDG) brain PET/MR with PWI. Two blinded readers predicted low versus high-grade tumor (for Group A) and tumor recurrence versus TIE (for Group B) based solely on tumor rCBV (regional cerebral blood volume) and SUV (standardized uptake values). Tumor histopathology at resection was the reference standard. Using rCBVmean ≤ 1.74 as a cut-off, 100 % sensitivity and 74 % specificity were observed, whereas 75 % sensitivity and 89.7 % specificity were observed with SUVmean ≤ 4.0 as a cut-off to classify patients as test positive for low-grade tumors (Group A) and TIE (Group B). Diagnostic accuracy for detection of low-grade tumors was 90 % using PWI and 40 % using PET in Group A (p = 0.056); for detection of TIE in Group B, diagnostic accuracy was 94.1 % using PWI and 55.6 % using PET (p = 0.033). No significant correlation was demonstrated between rCBV parameters and SUV in Group A (mean values: p > 0.403), Group B (p > 0.06) and in the entire population (p > 0.07). Best overall sensitivity and specificity were obtained using rCBVmean ≤ 1.74 and SUVmean ≤ 4.0 cut-off values. PWI demonstrated better diagnostic accuracy in both groups. Poor correlation was observed between FDG and rCBV parameters.
引用
收藏
页码:287 / 293
页数:6
相关论文
共 98 条
[1]  
Griffith B(2015)Perfusion imaging in neuro-oncology: basic techniques and clinical applications Radiol Clin North Am 53 497-511
[2]  
Jain R(2014)Clinical oncologic applications of PET/MRI: a new horizon Am J Nucl Med Mol Imaging 4 202-212
[3]  
Partovi S(2015)18F-fluorodeoxyglucose PET/computed tomography for primary brain tumors PET Clin 10 59-73
[4]  
Kohan A(2014)Bhangoo RS Applications of positron emission tomography in neuro-oncology: a clinical approach Surgeon 12 148-157
[5]  
Rubbert C(2002)Positron emission tomography imaging of brain tumors Neuroimaging Clin N Am 12 615-626
[6]  
Segtnan EA(2014)Does the novel integrated PET/MRI Offer the same diagnostic performance as PET/CT for oncological indications? Plos One 9 e90844-S104
[7]  
Hess S(2009)Towards quantitative PET/MRI: a review of MR-baed attenuation correction techniques Eur J Nucl Med Mol Imaging 36 S93-1524
[8]  
Grupe P(2013)Image artifacts from MR-based attenuation correction in clinical, whole body PET/MRI MAGMA 39 1519-545
[9]  
Demetriades AK(2014)Comparison of 18F-FET PET and perfusion-weighted MR imaging: a PET/MR imaging hybrid study in patients with brain tumors J Nucl Med 55 540-765
[10]  
Almeida AC(2010)Differentiating radiation necrosis from tumor recurrence in high-grade gliomas: assessing the efficacy of 18F-FDG PET, 11C-methionine PET and perfusion MRI Clin Neurol Neurosurg 112 758-457