Polymethylthiophene/Nafion-modified glassy carbon electrode for selective detection of dopamine in the presence of ascorbic acid

被引:0
|
作者
Vu Thi Huong
Toshinori Shimanouchi
Do Phuc Quan
Hiroshi Umakoshi
Pham Hung Viet
Ryoichi Kuboi
机构
[1] Osaka University,Department of Chemical Science and Engineering, Graduate School of Engineering Science
[2] Hanoi University of Science,Research Centre for Environmental Technology and Sustainable Development
[3] Vietnam National University,undefined
来源
关键词
Ascorbic acid; Dopamine; Electrochemical; Nafion; Polymethylthiophene;
D O I
暂无
中图分类号
学科分类号
摘要
The possible use of an electrode modified with electroactive conductive poly(3-methylthiophene) (PMeT)/Nafion as a chemical sensor was investigated for the voltammetric analysis of Dopamine (DA). The electrochemical behavior of dopamine was examined by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. By using a PMeT-modified glassy carbon (GC/PMeT) electrode, DA and Ascorbic Acid (AA) signals could be separated but the AA at high concentrations still caused significant interference by overlapping the DA peak. In comparison to the GC/PMeT electrode, the glassy carbon (GC/Nafion/PMeT) electrode modified with hybrid film Nafion/PMeT was found to permit a superior separation by shifting the oxidation of AA peak toward the less positive potential. The DPV curves for a mixture of DA and AA at an GC/Nafion/PMeT electrode in a 0.1 M H2SO4 solution showed peaks of DA and AA, at 0.45 and 0.21 V, respectively, indicating that the difference in the oxidation potential was 240 mV. In the 0.1 M H2SO4 solution, the oxidation peak current on the differential pulse voltammograms for the GC/PMeT electrode increased linearly with the concentration of DA in the range 1 × 10−6 to 1 × 10−3 M, and the oxidation peak current on the differential pulse voltammograms for the GC/Nafion/PMeT electrode in the range 5 × 10−7 to 2 × 10−4 M. The DA detection sensitivity of the GC/Nafion/PMeT electrode (26.7 μA μM−1 cm−2) was 22 times higher than that of the GC/PMeT electrode (1.21 μA μM−1 cm−2).
引用
收藏
页码:2035 / 2042
页数:7
相关论文
共 50 条
  • [21] Highly Sensitive and Selective Detection of Dopamine at Poly (chromotrope 2B)-Modified Glassy Carbon Electrode in the Presence of Uric Acid and Ascorbic Acid
    Li, Xiao-Bo
    Rahman, Md Mahbubur
    Xu, Guang-Ri
    Lee, Jae-Joon
    ELECTROCHIMICA ACTA, 2015, 173 : 440 - 447
  • [22] Electrochemical sensor for the detection of dopamine in the presence of ascorbic acid in neutral pH on graphitized nanoporous carbon modified glassy carbon electrode
    Thangaraj, Rajendiran
    Mufeedah, Muringah Kandy
    Kumar, Annamalai Senthil
    RECENT TRENDS IN ADVANCED MATERIALS, 2012, 584 : 334 - 338
  • [23] Selective determination of dopamine in the presence of ascorbic acid at porous-carbon-modified glassy carbon electrodes
    Song, Shuqing
    Gao, Qiuming
    Xia, Kaisheng
    Gao, Lu
    ELECTROANALYSIS, 2008, 20 (11) : 1159 - 1166
  • [24] A Poly(trypan blue)-Modified Anodized Glassy Carbon Electrode for the Sensitive Detection of Dopamine in the Presence of Uric Acid and Ascorbic Acid
    Li, Xiao-Bo
    Rahman, Md. Mahbubur
    Ge, Chuang-Ye
    Xu, Guang-Ri
    Lee, Jae-Joon
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (02) : B34 - B39
  • [25] Selective determination of dopamine in the presence of ascorbic acid at the carbon atom wire modified electrode
    Xue, KH
    Tao, FF
    Xu, W
    Yin, SY
    Liu, JM
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 578 (02) : 323 - 329
  • [26] Polyeugenol-modified platinum electrode for selective detection of dopamine in the presence of ascorbic acid
    Ciszewski, A
    Milczarek, G
    ANALYTICAL CHEMISTRY, 1999, 71 (05) : 1055 - 1061
  • [27] Selective detection of dopamine with poly(diphenylamine sulfonic acid) modified electrode in the presence of ascorbic acid
    Mutlu, Mehmet Mutluhan
    Erdogdu, Gamze
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (07) : 660 - 665
  • [28] Selective detection of dopamine with poly(diphenylamine sulfonic acid) modified electrode in the presence of ascorbic acid
    Mehmet Mutluhan Mutlu
    Gamze Erdoǧdu
    Journal of Analytical Chemistry, 2011, 66 : 660 - 665
  • [29] Fabrication of GNPs/CDSH-Fc/nafion modified electrode for the detection of dopamine in the presence of ascorbic acid
    Chen, Ming
    Wei, Xiujuan
    Qian, Hui
    Diao, Guowang
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2011, 31 (07): : 1271 - 1277
  • [30] Carbon nanotubes/alizarin red S–poly(vinylferrocene) modified glassy carbon electrode for selective determination of dopamine in the presence of ascorbic acid
    Mine Şen
    Uğur Tamer
    Nuran Özçiçek Pekmez
    Journal of Solid State Electrochemistry, 2012, 16 : 457 - 463