Adverse effects of total hip arthroplasty on the hip abductor and adductor muscle lengths and moment arms during gait

被引:0
作者
Xiangjun Hu
Nan Zheng
Wei-Chun Hsu
Jingwei Zhang
Huiwu Li
Yunsu Chen
Kerong Dai
Tsung-Yuan Tsai
机构
[1] School of Biomedical Engineering & Med-X Research Institute,Shanghai Key Laboratory of Orthopaedic Implants & Clinical Translation R&D Center of 3D Printing Technology, Department of Orthopaedic Surgery
[2] Shanghai Jiao Tong University; Engineering Research Center of Digital Medicine and Clinical Translation,Graduate Institute of Biomedical Engineering
[3] Ministry of Education,Department of Orthopaedic
[4] Shanghai Ninth People’s Hospital,undefined
[5] Shanghai Jiao Tong University School of Medicine,undefined
[6] National Taiwan University of Science and Technology,undefined
[7] Shanghai Jiao Tong University Affiliated Sixth People’s Hospital,undefined
来源
Journal of Orthopaedic Surgery and Research | / 15卷
关键词
Total hip arthroplasty; Biomechanics; Muscle length; Moment arm; Hip abductor muscle; Hip adductor muscle;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 105 条
[1]  
Park KK(2016)Three-dimensional in vivo difference between native acetabular version and acetabular component version influences iliopsoas impingement after total hip arthroplasty Int Orthop 40 1807-1812
[2]  
Tsai TY(2014)Gait and gait-related activities of daily living after total hip arthroplasty: a systematic review Clin Biomechanics (Bristol, Avon) 29 705-718
[3]  
Dimitriou D(2018)Biomechanical changes and recovery of gait function after total hip arthroplasty for osteoarthritis: a systematic review and meta-analysis Osteoarthr Cartil 26 847-863
[4]  
Kwon YM(2001)Instability in primary total hip arthroplasty with the direct lateral approach Clin Orthop Relat Res 393 168-180
[5]  
Kolk S(2000)Three-dimensional gait analysis in women with a total hip arthroplasty Clin Biomechanics (Bristol, Avon) 15 504-515
[6]  
Minten MJ(1994)Causes of dislocation of total hip arthroplasty. CT study of component alignment J Bone Joint Surg Br 76 45-48
[7]  
van Bon GE(2017)Effect of changes of femoral offset on abductor and joint reaction forces in total hip arthroplasty Arch Orthop Trauma Surg 137 1579-1585
[8]  
Rijnen WH(2013)A novel dual fluoroscopic imaging method for determination of THA kinematics: in-vitro and in-vivo study J Biomech 46 1300-1304
[9]  
Geurts AC(2015)Asymmetric hip kinematics during gait in patients with unilateral total hip arthroplasty: in vivo 3-dimensional motion analysis J Biomech 48 555-559
[10]  
Verdonschot N(2015)Does component alignment affect gait symmetry in unilateral total hip arthroplasty patients? Clin Biomechanics (Bristol, Avon) 30 802-807