The fate of patellar tendon and infrapatellar fat pad after arthroscopy via central portal

被引:0
作者
Ahmet Bayar
Egemen Turhan
Tülay Özer
Selçuk Keser
Ahmet Ege
Zuhal Erdem
机构
[1] Zonguldak Karaelmas University,Department of Orthopaedics and Traumatology, Faculty of Medicine
[2] İzmit Gözlem Radiology Center,Department of Radiology, Faculty of Medicine
[3] Zonguldak Karaelmas University,undefined
来源
Knee Surgery, Sports Traumatology, Arthroscopy | 2008年 / 16卷
关键词
Central portal; Arthroscopy; Patellar tendon; Chronic tendinitis; Fibrosis;
D O I
暂无
中图分类号
学科分类号
摘要
Central patellar (CP) portal is an accessory portal in arthroscopic knee surgery, which generally is considered to be safe. In this cross sectional study, we aimed to delineate the clinical and radiological outcome of patellar tendon (PT) and Hoffa’s fat pad after the use of this approach. From our hospital records, patients who underwent arthroscopy via CP portal were identified and were invited for the study. There were16 men and 4 women with a mean age of 32 years. Mean follow-up time was 28 months. Meniscectomy had been performed for irreparable bucket-handle type medial meniscal tears in all patients. At the latest follow-up, no patients had anterior knee pain and physical examination was normal. Mean PT thickness of operated knees measured with Ultrasonography was 5.63 ± 1.56, while it was 3.76 ± 0.46 mm in contralateral knees and the difference was significant. Contour irregularity of PT and focal hypoechoic areas were found in 17 patients, two of which also had hyperechogenic calcification focuses. Abnormal signal intensity of PT was also found in 17 patients with Magnetic Resonance Imaging (MRI). Eleven of these had decreased signal intensity within the tendon which was interpreted as fibrosis. In six patients, increased signal intensity, radiologically similar to chronic tendinitis, was detected. Four patients had decreased signal intensity in the Hoffa’s fat pad. Local fibrous tissues in patellar tendon might cause weakness in the tendon. This study showed that although CP portal did not cause any clinical problems in a low demand group of patients, it leads to a significant radiological sequela in the tendon, biomechanical significance of which needs to be clarified.
引用
收藏
页码:1114 / 1120
页数:6
相关论文
共 62 条
  • [1] Bergström R(1984)Comparison of open and endoscopic meniscectomy Clin Orthop Relat Res 184 133-136
  • [2] Hamberg P(2007)Three-portal technique for anterior cruciate ligament reconstruction: use of a central medial portal Arthroscopy 23 325-5
  • [3] Lysholm J(2001)Asymptomatic hypoechoic regions on patellar tendon ultrasound: a 4-year clinical and ultrasound followup of 46 tendons Scand J Med Sci Sports 11 321-327
  • [4] Gillquist J(1980)A comparison between the transpatellar tendon and the lateral approach to the knee joint during arthroscopy. A cadaver study Am J Sports Med 8 103-105
  • [5] Cohen SB(1976)A new modification of the technique of arthroscopy of the knee joint Acta Chir Scand 142 123-130
  • [6] Fu FH(1979)Arthroscopic visualization of the posteromedial compartment of the knee joint Orthop Clin North Am 10 545-547
  • [7] Cook JL(1996)Patellar tendinosis (jumper’s knee): findings at histopathologic examination, US, and MR imaging. Victorian Institute of Sport Tendon Study Group Radiology 200 821-827
  • [8] Khan KM(2001)High portal: practical philosophy for positioning portals in knee arthroscopy Arthroscopy 17 333-337
  • [9] Kiss ZS(1986)Arthroscopic examination of the patellofemoral joint using a central, one-portal technique Orthop Clin North Am 17 263-268
  • [10] Coleman BD(1987)Isokinetic evaluation of the knee after arthroscopic meniscectomy: comparison between anterolateral and central approaches Arthroscopy 3 123-126