摘要
Abstract: This paper describes the main aspects of designing a fault-tolerant synchronous electric motor for an aircraft fuel pump and the operation of an electric machine with various failure options—a phase failure (inverter failure), phase short circuit, and interwinding short circuit—and also describes actions aimed at minimizing damage from malfunction. © 2022, Allerton Press, Inc.