Image quality and radiation dose of ECG-triggered High-Pitch Dual-Source cardiac computed tomography angiography in children for the evaluation of central vascular stents

被引:0
|
作者
Christian A. Barrera
Hansel J. Otero
Ammie M. White
David Saul
David M. Biko
机构
[1] Children’s Hospital of Philadelphia,Department of Radiology
来源
The International Journal of Cardiovascular Imaging | 2019年 / 35卷
关键词
Children; Cardiac CT; Stent; Dual-source CT; High Pitch; ECG-triggered;
D O I
暂无
中图分类号
学科分类号
摘要
Assess image quality and radiation dose of ECG-triggered High-Pitch Dual-Source CTA for the evaluation central vascular stents in children. We included all children ≤ 21 years old with one or more central vascular stents and available prospective ECG-triggered High-Pitch Dual-Source CTA performed at our institution between January 2015 and August 2017. Demographic and scanner information was retrieved. Two board-certified pediatric radiologists blinded to the clinical data, independently reviewed and scored each case using a four-point quality score. Scores 1, 2 and 3 were considered of diagnostic image quality. Inter-observer agreement and non-parametric test were used. 18 patients (10 girls, 8 boys) with a mean age of 9.47 ± 7.38 years (mean ± SD) met inclusion criteria. Thirty-two central vascular stents were evaluated. Mean quality score was 2.07 ± 0.94 with 12.5% (4/32) of the cases classified as unevaluable. Interobserver agreement was excellent (k = 0.86). There is no significant difference between quality score and stent location (p = 0.07). There is a significant difference with stent material as all non-diagnostic scores were only seen in covered stents made of platinum-iridium (p < 0.001). There was no association between image quality and age, height, weight, BSA, heart rate, radiation dose or stent lumen size (p > 0.05). ECG-triggered high-pitch spiral DS-CTA offers appropriate image quality for assessment of central vascular stents in children.
引用
收藏
页码:367 / 374
页数:7
相关论文
共 50 条
  • [21] Dual-source cardiac computed tomography: image quality and dose considerations
    Stephan Achenbach
    Katharina Anders
    Willi A. Kalender
    European Radiology, 2008, 18 : 1188 - 1198
  • [22] Image Quality of Coronary Arteries on Non-electrocardiography-gated High-Pitch Dual-Source Computed Tomography in Children with Congenital Heart Disease
    Kanie, Yuichiro
    Sato, Shuhei
    Tada, Akihiro
    Kanazawa, Susumu
    PEDIATRIC CARDIOLOGY, 2017, 38 (07) : 1393 - 1399
  • [23] Image Quality of Coronary Arteries on Non-electrocardiography-gated High-Pitch Dual-Source Computed Tomography in Children with Congenital Heart Disease
    Yuichiro Kanie
    Shuhei Sato
    Akihiro Tada
    Susumu Kanazawa
    Pediatric Cardiology, 2017, 38 : 1393 - 1399
  • [24] High-Pitch Spiral Computed Tomography Effect on Image Quality and Radiation Dose in Pediatric Chest Computed Tomography
    Lell, Michael M.
    May, Matthias
    Deak, Paul
    Alibek, Sedat
    Kuefner, Michael
    Kuettner, Axel
    Koehler, Henrik
    Achenbach, Stephan
    Uder, Michael
    Radkow, Tanja
    INVESTIGATIVE RADIOLOGY, 2011, 46 (02) : 116 - 123
  • [25] Radiation dose and diagnostic accuracy of high-pitch dual-source coronary angiography in the evaluation of coronary artery stenoses
    Koplay, M.
    Erdogan, H.
    Avci, A.
    Sivri, M.
    Demir, K.
    Guler, I.
    Demir, L. S.
    Paksoy, Y.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2016, 97 (04) : 461 - 469
  • [26] Free-breathing high-pitch 80 kVp dual-source computed tomography of the pediatric chest: Image quality, presence of motion artifacts and radiation dose
    Bodelle, Boris
    Fischbach, Constanze
    Booz, Christian
    Yel, Ibrahim
    Frellesen, Claudia
    Beeres, Martin
    Vogl, Thomas J.
    Scholtz, Jan-Erik
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 89 : 208 - 214
  • [27] Accuracy, image quality and radiation dose comparison of high-pitch spiral and sequential acquisition on 128-slice dual-source CT angiography in children with congenital heart disease
    Pei Nie
    Ximing Wang
    Zhaoping Cheng
    Xiaopeng Ji
    Yanhua Duan
    Jiuhong Chen
    European Radiology, 2012, 22 : 2057 - 2066
  • [28] High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experience
    Beeres, Martin
    Schell, Boris
    Mastragelopoulos, Aristidis
    Herrmann, Eva
    Kerl, Josef Matthias
    Gruber-Rouh, Tatjana
    Lee, Clara
    Siebenhandl, Petra
    Bodelle, Boris
    Zangos, Stephan
    Vogl, Thomas J.
    Jacobi, Volkmar
    Bauer, Ralf W.
    EUROPEAN RADIOLOGY, 2012, 22 (01) : 129 - 137
  • [29] High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experience
    Martin Beeres
    Boris Schell
    Aristidis Mastragelopoulos
    Eva Herrmann
    Josef Matthias Kerl
    Tatjana Gruber-Rouh
    Clara Lee
    Petra Siebenhandl
    Boris Bodelle
    Stephan Zangos
    Thomas J. Vogl
    Volkmar Jacobi
    Ralf W. Bauer
    European Radiology, 2012, 22 : 129 - 137
  • [30] Accuracy, image quality and radiation dose comparison of high-pitch spiral and sequential acquisition on 128-slice dual-source CT angiography in children with congenital heart disease
    Nie, Pei
    Wang, Ximing
    Cheng, Zhaoping
    Ji, Xiaopeng
    Duan, Yanhua
    Chen, Jiuhong
    EUROPEAN RADIOLOGY, 2012, 22 (10) : 2057 - 2066