Early detection of lung function decrements in children and adolescents with cystic fibrosis using new reference values

被引:0
作者
Angela Zacharasiewicz
Sabine Renner
Flora Haderer
Michael Weber
Eleonore Dehlink
Zsolt Szepfalusi
Thomas Frischer
机构
[1] Wilhelminenspital Vienna,Department of Pediatrics and Adolescent Medicine
[2] Medical University Hospital Vienna,Department of Pediatrics
[3] Medical University Vienna,Department of Biomedical Imaging and Image Guided Therapy
[4] The Royal Brompton Hospital,Department of Pediatrics
来源
Wiener klinische Wochenschrift | 2017年 / 129卷
关键词
Cystic fibrosis; Children; Spirometry; Lung function; Reference values;
D O I
暂无
中图分类号
学科分类号
摘要
Interpretation of lung function values in children with cystic fibrosis (CF) depends on the applied reference values. We hypothesize that differences between the new global lung function initiative (GLI) values and the formerly used Zapletal et al. values produce significantly different clinical results. We analyzed 3719 lung function measurements of 108 children and adolescents (n = 54 male; aged 6–18 years) with CF treated between September 1991 and July 2009. Data were analyzed in milliliters (ml) and % predicted (pred.) and interpreted using Zapletal and GLI reference values. Applying GLI compared to Zapletal resulted in significantly lower mean forced expiratory volume in 1s (FEV1)% pred. values: Zapletal 86.6% (SD 20.6), GLI 79.9% (SD 20.3) and 32% (n = 497/1543) were misclassified as normal when using Zapletal. Despite showing no overall differences in FEV1 and forced vital capacity (FVC) between concomitant Pseudomonas detection (PA+) in n = 938 and Pseudomonas negative (PA-) (n = 2781) using either reference PA+ resulted in lower FEV1 and FVC values with increasing age; however, measurement of small airway obstruction with forced expiratory flow at 75% of FVC (FEF75) values – available for Zapletal –showed significant differences. Reassurance regarding lung function when using old reference values may occur with potential clinical significance. Discrepancies in lung function interpretation underline the importance of using uniform and best available reference values.
引用
收藏
页码:533 / 539
页数:6
相关论文
共 98 条
[81]  
Byard PJ(undefined)undefined undefined undefined undefined-undefined
[82]  
Davis PB(undefined)undefined undefined undefined undefined-undefined
[83]  
Dasenbrook EC(undefined)undefined undefined undefined undefined-undefined
[84]  
Merlo CA(undefined)undefined undefined undefined undefined-undefined
[85]  
Diener-West M(undefined)undefined undefined undefined undefined-undefined
[86]  
Lechtzin N(undefined)undefined undefined undefined undefined-undefined
[87]  
Boyle MP(undefined)undefined undefined undefined undefined-undefined
[88]  
Bakker EM(undefined)undefined undefined undefined undefined-undefined
[89]  
Borsboom GJ(undefined)undefined undefined undefined undefined-undefined
[90]  
van der Wiel-Kooij EC(undefined)undefined undefined undefined undefined-undefined