Assessing the reproducibility of high temporal and spatial resolution dynamic contrast-enhanced magnetic resonance imaging in patients with gliomas

被引:0
|
作者
Woo Hyeon Lim
Joon Sik Park
Jaeseok Park
Seung Hong Choi
机构
[1] Seoul National University College of Medicine,Department of Radiology
[2] Sungkyunkwan University,Department of Biomedical Engineering
[3] Sungkyunkwan University,Department of Intelligent Precision Healthcare Convergence
[4] Seoul National University,Center for Nanoparticle Research, Institute for Basic Science (IBS)
[5] Seoul National University,School of Chemical and Biological Engineering
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Temporal and spatial resolution of dynamic contrast-enhanced MR imaging (DCE-MRI) is critical to reproducibility, and the reproducibility of high-resolution (HR) DCE-MRI was evaluated. Thirty consecutive patients suspected to have brain tumors were prospectively enrolled with written informed consent. All patients underwent both HR-DCE (voxel size, 1.1 × 1.1 × 1.1 mm3; scan interval, 1.6 s) and conventional DCE (C-DCE; voxel size, 1.25 × 1.25 × 3.0 mm3; scan interval, 4.0 s) MRI. Regions of interests (ROIs) for enhancing lesions were segmented twice in each patient with glioblastoma (n = 7) to calculate DCE parameters (Ktrans, Vp, and Ve). Intraclass correlation coefficients (ICCs) of DCE parameters were obtained. In patients with gliomas (n = 25), arterial input functions (AIFs) and DCE parameters derived from T2 hyperintense lesions were obtained, and DCE parameters were compared according to WHO grades. ICCs of HR-DCE parameters were good to excellent (0.84–0.95), and ICCs of C-DCE parameters were moderate to excellent (0.66–0.96). Maximal signal intensity and wash-in slope of AIFs from HR-DCE MRI were significantly greater than those from C-DCE MRI (31.85 vs. 7.09 and 2.14 vs. 0.63; p < 0.001). Both 95th percentile Ktrans and Ve from HR-DCE and C-DCE MRI could differentiate grade 4 from grade 2 and 3 gliomas (p < 0.05). In conclusion, HR-DCE parameters generally showed better reproducibility than C-DCE parameters, and HR-DCE MRI provided better quality of AIFs.
引用
收藏
相关论文
共 50 条
  • [1] Assessing the reproducibility of high temporal and spatial resolution dynamic contrast-enhanced magnetic resonance imaging in patients with gliomas
    Lim, Woo Hyeon
    Park, Joon Sik
    Park, Jaeseok
    Choi, Seung Hong
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [2] Spatial and temporal resolution effects on dynamic contrast-enhanced magnetic resonance mammography
    Aref, Michael
    Handbury, Josh D.
    Ji, Jim Xiuquan
    Aref, Susanne
    Wiener, Erik C.
    MAGNETIC RESONANCE IMAGING, 2007, 25 (01) : 14 - 34
  • [3] Clinical application of bilateral high temporal and spatial resolution dynamic contrast-enhanced magnetic resonance imaging of the breast at 7 T
    K. Pinker
    W. Bogner
    P. Baltzer
    S. Trattnig
    S. Gruber
    O. Abeyakoon
    M. Bernathova
    O. Zaric
    P. Dubsky
    Z. Bago-Horvath
    M. Weber
    D. Leithner
    T. H. Helbich
    European Radiology, 2014, 24 : 913 - 920
  • [4] Clinical application of bilateral high temporal and spatial resolution dynamic contrast-enhanced magnetic resonance imaging of the breast at 7 T
    Pinker, K.
    Bogner, W.
    Baltzer, P.
    Trattnig, S.
    Gruber, S.
    Abeyakoon, O.
    Bernathova, M.
    Zaric, O.
    Dubsky, P.
    Bago-Horvath, Z.
    Weber, M.
    Leithner, D.
    Helbich, T. H.
    EUROPEAN RADIOLOGY, 2014, 24 (04) : 913 - 920
  • [5] Effect of Temporal Resolution on Diagnostic Performance of Dynamic Contrast-Enhanced Magnetic Resonance Imaging of the Prostate
    Othman, Ahmed E.
    Falkner, Florian
    Weiss, Jakob
    Kruck, Stephan
    Grimm, Robert
    Martirosian, Petros
    Nikolaou, Konstantin
    Notohamiprodjo, Mike
    INVESTIGATIVE RADIOLOGY, 2016, 51 (05) : 290 - 296
  • [6] High-Resolution Magnetic Resonance Colonography and Dynamic Contrast-Enhanced Magnetic Resonance Imaging in a Murine Model of Colitis
    Mustafi, Devkumar
    Fan, Xiaobing
    Dougherty, Urszula
    Bissonnette, Marc
    Karczmar, Gregory S.
    Oto, Aytekin
    Hart, John
    Markiewicz, Erica
    Zamora, Marta
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (04) : 922 - 929
  • [7] High Spatial and Temporal Resolution Dynamic Contrast-Enhanced Magnetic Resonance Angiography Using Compressed Sensing with Magnitude Image Subtraction
    Rapacchi, Stanislas
    Han, Fei
    Natsuaki, Yutaka
    Kroeker, Randall
    Plotnik, Adam
    Lehrman, Evan
    Sayre, James
    Laub, Gerhard
    Finn, J. Paul
    Hu, Peng
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (05) : 1771 - 1783
  • [8] Contrast agents in dynamic contrast-enhanced magnetic resonance imaging
    Yan, Yuling
    Sun, Xilin
    Shen, Baozhong
    ONCOTARGET, 2017, 8 (26) : 43491 - 43505
  • [9] Dynamic contrast-enhanced magnetic resonance imaging as an imaging biomarker
    Hylton, Nola
    JOURNAL OF CLINICAL ONCOLOGY, 2006, 24 (20) : 3293 - 3298
  • [10] Dynamic contrast-enhanced imaging of the breast with magnetic resonance
    Cron, GO
    Santyr, G
    Kelcz, F
    IMTC/97 - IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE: SENSING, PROCESSING, NETWORKING, PROCEEDINGS VOLS 1 AND 2, 1997, : 1354 - 1356