Measuring Systems for Thermometer Calibration in Low-Temperature Range

被引:0
作者
A. Szmyrka-Grzebyk
L. Lipiński
H. Manuszkiewicz
A. Kowal
A. Grykałowska
D. Jancewicz
机构
[1] Institute of Low Temperature and Structure Research,
来源
International Journal of Thermophysics | 2011年 / 32卷
关键词
Calibration; Temperature scale; Thermometry;
D O I
暂无
中图分类号
学科分类号
摘要
The national temperature standard for the low-temperature range between 13.8033 K and 273.16 K has been established in Poland at the Institute of Low Temperature and Structure Research (INTiBS). The standard consists of sealed cells for realization of six fixed points of the International Temperature Scale of 1990 (ITS-90) in the low-temperature range, an adiabatic cryostat and Isotech water and mercury triple-point baths, capsule standard resistance thermometers (CSPRT), and AC and DC bridges with standard resistors for thermometers resistance measurements. INTiBS calibrates CSPRTs at the low-temperature fixed points with uncertainties less than 1 mK. In lower temperature range—between 2.5 K and about 25 K — rhodium–iron (RhFe) resistance thermometers are calibrated by comparison with a standard which participated in the EURAMET.T-K1.1 comparison. INTiBS offers a calibration service for industrial platinum resistance thermometers and for digital thermometers between 77 K and 273 K. These types of thermometers may be calibrated at INTiBS also in a higher temperature range up to 550°C. The Laboratory of Temperature Standard at INTiBS acquired an accreditation from the Polish Centre for Accreditation. A management system according to EN ISO/IEC 17025:2005 was established at the Laboratory and presented on EURAMET QSM Forum.
引用
收藏
页码:2466 / 2476
页数:10
相关论文
共 50 条
[31]   Non-standard input signals for the calibration and optimisation of the measuring systems [J].
Layer, E .
MEASUREMENT, 2003, 34 (02) :179-186
[32]   Calibration Algorithm Automation for Data Measuring Channels of Electrical Power Systems [J].
Nikolayev, M. U. ;
Nikolayeva, E. V. ;
Leskov, I. A. ;
Biryukov, Sergey V. ;
Larioshkin, V. A. ;
Varvarskiy, A. V. .
2017 XI INTERNATIONAL IEEE SCIENTIFIC AND TECHNICAL CONFERENCE DYNAMICS OF SYSTEMS, MECHANISMS AND MACHINES (DYNAMICS), 2017,
[33]   Mechanical measurements - Calibration of vacuum gauges in an expanded low pressure range [J].
Kuz'min, VV .
MEASUREMENT TECHNIQUES, 2004, 47 (12) :1188-1190
[34]   Camera-LiDAR Wide Range Calibration in Traffic Surveillance Systems [J].
Jang, Byung-Jin ;
Kim, Taek-Lim ;
Park, Tae-Hyoung .
SENSORS, 2025, 25 (03)
[35]   Development of a Multi-temperature Calibration Method for Measuring Dielectric Properties of Food [J].
Chen, J. ;
Pitchai, K. ;
Birla, S. ;
Jones, D. D. ;
Subbiah, J. ;
Gonzalez, R. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (01) :626-634
[36]   Low-Temperature Thermometry Below 1 K at PTB [J].
Engert, J. ;
Heyer, D. ;
Fischer, J. .
TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 8, 2013, 1552 :136-141
[37]   Uncertainties in blackbody corrections for low-temperature radiation thermometers [J].
Saunders, P. ;
Manoi, A. .
METROLOGIA, 2020, 57 (02)
[38]   LOW-TEMPERATURE RESISTANCE OF P-INSB(MN) [J].
OBUKHOV, SA ;
NEGANOV, BS ;
KISELEV, YF ;
CHERNIKOV, AN ;
VEKSHINA, VS ;
PEPIK, NI ;
POPKOV, AN .
CRYOGENICS, 1991, 31 (10) :874-877
[39]   LOW-TEMPERATURE CALORIMETRY USING AN OPTICAL HEATING METHOD [J].
GUTSMIEDL, P ;
PROBST, C ;
ANDRES, K .
CRYOGENICS, 1991, 31 (01) :54-57
[40]   DSC temperature calibration over the range-125 °C to 50 °C [J].
Ashton, Gage P. ;
Charsley, Edward L. ;
Harding, Lindsay P. ;
Parkes, Gareth M. B. .
THERMOCHIMICA ACTA, 2021, 698