Measuring Systems for Thermometer Calibration in Low-Temperature Range

被引:0
作者
A. Szmyrka-Grzebyk
L. Lipiński
H. Manuszkiewicz
A. Kowal
A. Grykałowska
D. Jancewicz
机构
[1] Institute of Low Temperature and Structure Research,
来源
International Journal of Thermophysics | 2011年 / 32卷
关键词
Calibration; Temperature scale; Thermometry;
D O I
暂无
中图分类号
学科分类号
摘要
The national temperature standard for the low-temperature range between 13.8033 K and 273.16 K has been established in Poland at the Institute of Low Temperature and Structure Research (INTiBS). The standard consists of sealed cells for realization of six fixed points of the International Temperature Scale of 1990 (ITS-90) in the low-temperature range, an adiabatic cryostat and Isotech water and mercury triple-point baths, capsule standard resistance thermometers (CSPRT), and AC and DC bridges with standard resistors for thermometers resistance measurements. INTiBS calibrates CSPRTs at the low-temperature fixed points with uncertainties less than 1 mK. In lower temperature range—between 2.5 K and about 25 K — rhodium–iron (RhFe) resistance thermometers are calibrated by comparison with a standard which participated in the EURAMET.T-K1.1 comparison. INTiBS offers a calibration service for industrial platinum resistance thermometers and for digital thermometers between 77 K and 273 K. These types of thermometers may be calibrated at INTiBS also in a higher temperature range up to 550°C. The Laboratory of Temperature Standard at INTiBS acquired an accreditation from the Polish Centre for Accreditation. A management system according to EN ISO/IEC 17025:2005 was established at the Laboratory and presented on EURAMET QSM Forum.
引用
收藏
页码:2466 / 2476
页数:10
相关论文
共 50 条
[21]   Epoxy encapsulation of the Cernox™ SD thermometer for measuring the temperature of surfaces in liquid helium [J].
Dhuley, R. C. ;
Van Sciver, S. W. .
CRYOGENICS, 2016, 77 :49-52
[22]   Calibration of Thermocouples for Low Temperature Applications [J].
Singh, Devendra ;
Kumar, Pravin ;
Prasad, Sumer Chand .
2016 INTERNATIONAL CONFERENCE ON RECENT ADVANCES AND INNOVATIONS IN ENGINEERING (ICRAIE), 2016,
[23]   LOW TEMPERATURE CALIBRATION FACILITIES AT KRISS [J].
Yang, Inseok ;
Kim, Yong-Gyoo ;
Song, Chang Ho ;
Kang, Kee Hoon ;
Gam, Kee Sool .
XIX IMEKO WORLD CONGRESS: FUNDAMENTAL AND APPLIED METROLOGY, PROCEEDINGS, 2009, :1563-1566
[24]   Improved calibration for wide measuring ranges and low contents [J].
Huber, MKW .
ACCREDITATION AND QUALITY ASSURANCE, 1997, 2 (08) :367-374
[25]   A Low Temperature Comparator for Calibration of Industrial Thermometers in the Range-190 °C To-25 °C [J].
Bosma, R. ;
de Bruin-Barendregt, C. K. ;
van Breugel, R. ;
Peruzzi, A. .
TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 8, 2013, 1552 :480-485
[26]   The effects of temperature gradient on transient behavior of low-range differential air pressure calibration setup [J].
Ul Islam, Muhammad Nazar ;
Cheng, Peng ;
Oelmann, Bengt .
2015 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2015, :1488-1494
[27]   Calibration of vacuum gauges in an expanded low pressure range [J].
V. V. Kuz’min .
Measurement Techniques, 2004, 47 :1188-1190
[28]   Calibration of a radiosonde humidity sensor at low temperature and low pressure [J].
Lee, Sang-Wook ;
Choi, Byung Il ;
Woo, Sang-Bong ;
Kim, Jong Chul ;
Kim, Yong-Gyoo .
METROLOGIA, 2019, 56 (05)
[29]   Some insights on the calibration and drift of oceanographic probes for measuring temperature and conductivity [J].
Savonitto, Gilda ;
Comici, Cinzia ;
Kuchler, Stefano ;
Nair, Rajesh ;
Medeot, Nevio ;
Gerin, Riccardo .
2024 IEEE INTERNATIONAL WORKSHOP ON METROLOGY FOR THE SEA; LEARNING TO MEASURE SEA HEALTH PARAMETERS, METROSEA, 2024, :186-190
[30]   The Calibration of the Pressure Sensor at the Ultra-low Temperature [J].
Zhang, Jian ;
Zhang, Binzhen ;
Ji, Changhong ;
Liu, Jianlin ;
Li, Xianghong .
INFORMATION ENGINEERING FOR MECHANICS AND MATERIALS SCIENCE, PTS 1 AND 2, 2011, 80-81 :698-703