Mobile laminar air flow screen for additional operating room ventilation: Reduction of intraoperative bacterial contamination during total knee arthroplasty

被引:36
作者
Sossai D. [1 ]
Dagnino G. [2 ]
Sanguineti F. [3 ]
Franchin F. [3 ]
机构
[1] Health Safety and Prevention Department, A.O.U. San Martino, Genoa
[2] Italian Institute of Technology (IIT), Genoa
[3] Clinica Ortopedica Università, A.O.U. San Martino, Genoa
关键词
Infection; Laminar air flow; Total knee arthroplasty;
D O I
10.1007/s10195-011-0168-5
中图分类号
学科分类号
摘要
Background Surgical site infections are important complications in orthopedic surgery. A mobile laminar air flow (LAF) screen could represent a useful addition to an operating room (OR) with conventional turbulent air ventilation (12.5 air changes/h), as it could decrease the bacterial count near the operating field. The purpose of this study was to evaluate LAF efficacy at reducing bacterial contamination in the surgical area during 34 total knee arthroplasties (TKAs). Materials and methods The additional unit was used in 17 operations; the LAF was positioned beside the operating table between two of the surgeons, with the air flow directed towards the surgical area (wound). The whole team wore conventional OR clothing and the correct hygiene procedures and rituals were used. Bacterial air contamination (CFU/m 3) was evaluated in the wound area in 17 operations with the LAF unit and 17 without the LAF unit. Results The LAF unit reduced the mean bacterial count in the wound area from 23.5 CFU/m3 without the LAF to 3.5 CFU/m3 with the LAF (P<0.0001), which is below the suggested limit for anORwith ultraclean laminar ventilation. There were no significant differences in the mean bacterial count in the instrument table area: 28.6 CFU/m3 were recorded with the LAF (N = 6) unit and 30.8 CFU/m3 (N = 6) without the LAF unit (P = 0.631). During six operations with LAF and six without LAF, particle counts were performed and the number of 0.5 lm particles was analyzed. The particle counts decreased significantly when the LAF unit was used (P = 0.003). Conclusion When a mobile LAF unit was added to the standard OR ventilation, bacterial contamination of the wound area significantly decreased to below the accepted level for an ultraclean OR, preventing SSI infections. © The Author(s) 2011.
引用
收藏
页码:207 / 211
页数:4
相关论文
共 23 条
[1]  
Hanssen A.D., Rand J.A., Evaluation and treatment of infection at the site of a total hip or knee arthroplasty, Instr Course Lect, 48, pp. 111-122, (1999)
[2]  
Abudu A., Sivardeen K.A.Z., Grimer R.J., Pynsent P.B., Noy M., The outcome of perioperative wound infection after total hip and knee arthroplasty, International Orthopaedics, 26, 1, pp. 40-43, (2002)
[3]  
Knobben B.A.S., Van Horn J.R., Van Der Mei H.C., Busscher H.J., Evaluation of measures to decrease intra-operative bacterial contamination in orthopaedic implant surgery, Journal of Hospital Infection, 62, 2, pp. 174-180, (2006)
[4]  
Perencevich E.N., Sands K.E., Cosgrove S.E., Guadagnoli E., Meara E., Platt R., Health and economic impact of surgical site infections diagnosed after hospital discharge, Emerging Infectious Diseases, 9, 2, pp. 196-203, (2003)
[5]  
Lidwell O.M., Lowbury E.J.L., Whyte W., Airborne contamination of wounds in joint replacement operations: The relationship to sepsis rates, Journal of Hospital Infection, 4, 2, pp. 111-131, (1983)
[6]  
Whyte W., Hodgson R., Tinkler J., The importance of airborne bacterial contamination of wounds, Journal of Hospital Infection, 3, 2, pp. 123-135, (1982)
[7]  
Friberg S., Ardnor B., Lundholm R., Friberg B., The addition of a mobile ultra-clean exponential laminar airflow screen to conventional operating room ventilation reduces bacterial contamination to operating box levels, Journal of Hospital Infection, 55, 2, pp. 92-97, (2003)
[8]  
Pasquarella C., Sansebastiano G.E., Ferretti S., Saccani E., Fanti M., Moscato U., Giannetti G., Fornia S., Cortellini P., Vitali P., Signorelli C., A mobile laminar airflow unit to reduce air bacterial contamination at surgical area in a conventionally ventilated operating theatre, Journal of Hospital Infection, 66, 4, pp. 313-319, (2007)
[9]  
Lidwell O.M., Lowbury E.J.L., Whyte W., Effect of ultraclean air in operating rooms on deep sepsis in the joint after total hip or knee replacement: A randomised study, British Medical Journal, 285, 6334, pp. 10-14, (1982)
[10]  
Stocks G.W., Self S.D., Thompson B., Adame X.A., O'Connor D.P., Predicting bacterial populations based on airborne particulates: A study performed in nonlaminar flow operating rooms during joint arthroplasty surgery, Am J Infect Control, 38, 3, pp. 199-204, (2010)