Mechanistic Understanding of High Flow Nasal Cannula Therapy and Pressure Support with an In Vitro Infant Model

被引:0
作者
John V. Wilkins
Michelle T. Gardner
Ross Walenga
Sana Hosseini
P. Worth Longest
Laleh Golshahi
机构
[1] Virginia Commonwealth University,Department of Mechanical and Nuclear Engineering
[2] Virginia Commonwealth University,Division of Pediatric Critical Care Medicine, Department of Pediatrics, Children’s Hospital of Richmond
[3] Virginia Commonwealth University,Department of Pharmaceutics
[4] Virginia Commonwealth University,Department of Mechanical and Nuclear Engineering
来源
Annals of Biomedical Engineering | 2020年 / 48卷
关键词
Noninvasive ventilation; Occlusion; Pediatric; Positive distending pressure; Predictive correlations; Respiratory support; Test lung model;
D O I
暂无
中图分类号
学科分类号
摘要
Despite the increased use of high flow nasal cannula therapy, little has been done to predict airway pressures for a full breath cycle. A 3-month-old infant in vitro model was developed, which included the entire upper airway and the first three bifurcations of the lungs. A breathing simulator was used to create a realistic breath pattern, and high flow was provided using a Vapotherm unit. Four cannulas of varying sizes were used to assess the effects of the inner diameter and nasal occlusion of the cannulas on airway pressures. At 8 L min−1, end expiratory pressures of 0.821–1.306 cm H2O and 0.828–1.133 cm H2O were produced in the nasopharynx and trachea, respectively. Correlations were developed to predict full breath cycle airway pressures, based on the gas flow rate delivered, cannula dimensions, as well as the breathing flow rate, for the nasopharynx and trachea. Pearson correlation coefficients for the nasopharynx and trachea correlations were 0.991 and 0.992, respectively. The developed correlations could be used to determine the flow rate necessary for a cannula to produce pressures similar to CPAP settings. The proposed correlations accurately predict the regional airway pressure up to and including 7 cm H2O of support for the entire breath cycle.
引用
收藏
页码:624 / 633
页数:9
相关论文
共 145 条
[1]  
Bailes SA(2016)Evaluating the effect of flow and interface type on pressures delivered with bubble CPAP in a simulated model Respir. Care 61 333-339
[2]  
Firestone KS(2014)High-flow nasal cannula therapy for infants with bronchiolitis Cochrane Database Syst. Rev. 40 567-569
[3]  
Dunn DK(2001)Are infants really obligatory nasal breathers? Clin. Pediatr. (Phila) 45 69-74
[4]  
McNinch NL(2011)Nasal cannula, CPAP, and high-flow nasal cannula: effect of flow on temperature, humidity, pressure, and resistance Biomed. Instrum. Technol. 94 808-810
[5]  
Brown MF(1979)Pharyngeal pressures in nasal CPAP J. Pediatr. 90 79-81
[6]  
Volsko TA(2005)Pharyngeal pressure in preterm infants receiving nasal continuous positive airway pressure Arch. Dis. Child. Fetal Neonatal Ed. 105 1061-1065
[7]  
Beggs S(1994)Effect of low flow and high flow oxygen delivery on exercise tolerance and sensation of dyspnea: a study comparing the transtracheal catheter and nasal prongs Chest 103 1400-1405
[8]  
Wong ZH(2009)Research in high flow therapy: mechanisms of action Respir. Med. 377 1011-1018
[9]  
Kaul S(2011)Normal ranges of heart rate and respiratory rate in children from birth to 18 years of age: a systematic review of observational studies Lancet 81 1739-1743
[10]  
Ogden KJ(1996)Changes in airway resistance induced by nasal inhalation of cold dry, dry, or moist air in normal individuals J. Appl. Physiol. 378 1121-1131