Arterial pressure waveform derived cardiac output FloTrac/Vigileo system (third generation software): comparison of two monitoring sites with the thermodilution cardiac output

被引:0
|
作者
Sumit Vasdev
Sandeep Chauhan
Minati Choudhury
Millind P. Hote
Madhur Malik
Usha Kiran
机构
[1] C N Centre,Department of Cardiac Anaesthesia
[2] All India Institute of Medical Sciences,Department of Cardiothoracic and Vascular Surgery
[3] All India Institute of Medical Sciences,undefined
来源
Journal of Clinical Monitoring and Computing | 2012年 / 26卷
关键词
Cardiac output; Pulmonary artery catheter; Thermodilution; Arterial waveform derived cardiac output; Non invasive cardiac output;
D O I
暂无
中图分类号
学科分类号
摘要
The present study was conducted to study the effect of monitoring site, radial or femoral, for arterial pressure waveform derived cardiac output using FloTrac/Vigileo system with third generation software version 3.02 during cardiac surgery. The cardiac output derived from the two sites was also compared to the pulmonary artery catheter (PAC) derived cardiac output to reevaluate the relation between them using the newer software. The effect of cardiopulmonary bypass (CPB) was also studied by doing the sub analysis before and after bypass. Forty patients undergoing coronary artery bypass surgery with cardiopulmonary bypass were enrolled in the study. Cardiac output derived from radial artery (RADCO), femoral artery (FEMCO) using FloTrac/Vigileo system with third generation software version 3.02 and cardiac output using pulmonary artery catheter (PACCO) at predefined nine time points were recorded. Three hundred and forty two cardiac output data triplets were analysed. The Bland–Altman analysis of RADCO and FEMCO revealed a mean bias of −0.28 with percentage error of 20%. The pre CPB precision of both RADCO and FEMCO was 1.25 times as that of PACCO. The post CPB precision of FEMCO was 1.2 times of PACCO while that of RADCO was 1.7 times of PACCO. The third generation of FloTrac/Vigileo system shows good correlation between the radial and femoral derived cardiac outputs in both pre and post bypass periods. The newer software correlates better to PAC derived cardiac output in the post bypass period for femoral artery than radial artery.
引用
收藏
页码:115 / 120
页数:5
相关论文
共 50 条
  • [41] Clinical evaluation of the flotrac/vigileo™ system for continuous cardiac output monitoring in patients undergoing regional anesthesia for elective cesarean section: a pilot study
    Auler, Jose Otavio C., Jr.
    Torres, Marcelo L. A.
    Cardoso, Monica M.
    Tebaldi, Thais C.
    Schmidt, Andre P.
    Kondo, Mario M.
    Zugaib, Marcelo
    CLINICS, 2010, 65 (08) : 793 - 798
  • [42] Comparison of noninvasive continuous arterial waveform analysis (Nexfin) with transthoracic Doppler echocardiography for monitoring of cardiac output
    van der Spoel, Anna G. E.
    Voogel, Albertus J.
    Folkers, Anja
    Boer, Christa
    Bouwman, R. Arthur
    JOURNAL OF CLINICAL ANESTHESIA, 2012, 24 (04) : 304 - 309
  • [43] Estimation of cardiac output in a pharmacological trial using a simple method based on arterial blood pressure signal waveform: a comparison with pulmonary thermodilution and echocardiographic methods
    Jani Penttilä
    Amir Snapir
    Erkki Kentala
    Juha Koskenvuo
    Jussi Posti
    Mika Scheinin
    Harry Scheinin
    Tom Kuusela
    European Journal of Clinical Pharmacology, 2006, 62 : 401 - 407
  • [44] Estimation of cardiac output in a pharmacological trial using a simple method based on arterial blood pressure signal waveform:: a comparison with pulmonary thermodilution and echocardiographic methods
    Penttila, Jani
    Snapir, Amir
    Kentala, Erkki
    Koskenvuo, Juha
    Posti, Jussi
    Scheinin, Mika
    Scheinin, Harry
    Kuusela, Tom
    EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 2006, 62 (06) : 401 - 407
  • [45] Study of the accuracy of a radial arterial pressure waveform cardiac output measurement device after cardiac surgery
    Ordonez-Rufat, Pilar
    Mancho-Fora, Nuria
    Tebe-Cordomi, Cristian
    Polit-Martinez, Victoria
    Abellan-Lencina, Ricardo
    Fernandez-Alvarez, Joaquin
    Lopez-Delgado, Juan Carlos
    JOURNAL OF CARDIOTHORACIC SURGERY, 2023, 18 (01)
  • [46] Agreement in hemodynamic monitoring during orthotopic liver transplantation: a comparison of FloTrac/Vigileo at two monitoring sites with pulmonary artery catheter thermodilution
    Lee, Matthew
    Weinberg, Laurence
    Pearce, Brett
    Scurrah, Nicholas
    Story, David A.
    Pillai, Param
    McCall, Peter R.
    McNicol, Larry P.
    Peyton, Philip J.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (02) : 343 - 351
  • [47] Edwards FloTrac™ sensor and Vigileo™ monitor:: easy, accurate, reliable cardiac output assessment using the arterial pulse wave
    Manecke, Gerard R.
    EXPERT REVIEW OF MEDICAL DEVICES, 2005, 2 (05) : 523 - 527
  • [48] Comparison of pulmonary artery and arterial thermodilution cardiac output in critically ill patients
    Sakka, SG
    Reinhart, K
    Meier-Hellmann, A
    INTENSIVE CARE MEDICINE, 1999, 25 (08) : 843 - 846
  • [49] Agreement in hemodynamic monitoring during orthotopic liver transplantation: a comparison of FloTrac/Vigileo at two monitoring sites with pulmonary artery catheter thermodilution
    Matthew Lee
    Laurence Weinberg
    Brett Pearce
    Nicholas Scurrah
    David A. Story
    Param Pillai
    Peter R. McCall
    Larry P. McNicol
    Philip J. Peyton
    Journal of Clinical Monitoring and Computing, 2017, 31 : 343 - 351
  • [50] Pulmonary arterial thermodilution, femoral arterial thermodilution and bioreactance cardiac output monitoring in a pediatric hemorrhagic hypovolemic shock model
    Ballestero, Yolanda
    Urbano, Javier
    Lopez-Herce, Jesus
    Solana, Maria J.
    Botran, Marta
    Vinciguerra, Diego
    Bellon, Jose M.
    RESUSCITATION, 2012, 83 (01) : 125 - 129