Arterial pressure waveform derived cardiac output FloTrac/Vigileo system (third generation software): comparison of two monitoring sites with the thermodilution cardiac output

被引:0
|
作者
Sumit Vasdev
Sandeep Chauhan
Minati Choudhury
Millind P. Hote
Madhur Malik
Usha Kiran
机构
[1] C N Centre,Department of Cardiac Anaesthesia
[2] All India Institute of Medical Sciences,Department of Cardiothoracic and Vascular Surgery
[3] All India Institute of Medical Sciences,undefined
来源
Journal of Clinical Monitoring and Computing | 2012年 / 26卷
关键词
Cardiac output; Pulmonary artery catheter; Thermodilution; Arterial waveform derived cardiac output; Non invasive cardiac output;
D O I
暂无
中图分类号
学科分类号
摘要
The present study was conducted to study the effect of monitoring site, radial or femoral, for arterial pressure waveform derived cardiac output using FloTrac/Vigileo system with third generation software version 3.02 during cardiac surgery. The cardiac output derived from the two sites was also compared to the pulmonary artery catheter (PAC) derived cardiac output to reevaluate the relation between them using the newer software. The effect of cardiopulmonary bypass (CPB) was also studied by doing the sub analysis before and after bypass. Forty patients undergoing coronary artery bypass surgery with cardiopulmonary bypass were enrolled in the study. Cardiac output derived from radial artery (RADCO), femoral artery (FEMCO) using FloTrac/Vigileo system with third generation software version 3.02 and cardiac output using pulmonary artery catheter (PACCO) at predefined nine time points were recorded. Three hundred and forty two cardiac output data triplets were analysed. The Bland–Altman analysis of RADCO and FEMCO revealed a mean bias of −0.28 with percentage error of 20%. The pre CPB precision of both RADCO and FEMCO was 1.25 times as that of PACCO. The post CPB precision of FEMCO was 1.2 times of PACCO while that of RADCO was 1.7 times of PACCO. The third generation of FloTrac/Vigileo system shows good correlation between the radial and femoral derived cardiac outputs in both pre and post bypass periods. The newer software correlates better to PAC derived cardiac output in the post bypass period for femoral artery than radial artery.
引用
收藏
页码:115 / 120
页数:5
相关论文
共 50 条
  • [21] Cardiac Output Derived From Arterial Pressure Waveform Analysis: Validation of the Third-Generation Software in Patients Undergoing Orthotopic Liver Transplantation
    Tsai, Y. -F.
    Su, B. -C.
    Lin, C. -C.
    Liu, F. -C.
    Lee, W. -C.
    Yu, H. -P.
    TRANSPLANTATION PROCEEDINGS, 2012, 44 (02) : 433 - 437
  • [22] Evaluation of the Fourth-Generation FloTrac/Vigileo System in Comparison With the Intermittent Bolus Thermodilution Method in Patients Undergoing Cardiac Surgery
    Kusaka, Yusuke
    Ohchi, Fumihiro
    Minami, Toshiaki
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2019, 33 (04) : 953 - 960
  • [23] Systemic vascular resistance has an impact on the reliability of the Vigileo-FloTrac system in measuring cardiac output and tracking cardiac output changes
    Suehiro, K.
    Tanaka, K.
    Funao, T.
    Matsuura, T.
    Mori, T.
    Nishikawa, K.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 111 (02) : 170 - 177
  • [24] The ability of the Vigileo-FloTrac system to measure cardiac output and track cardiac output changes during one-lung ventilation
    Koichi Suehiro
    Katsuaki Tanaka
    Tokuhiro Yamada
    Tadashi Matsuura
    Takashi Mori
    Tomoharu Funao
    Kiyonobu Nishikawa
    Journal of Clinical Monitoring and Computing, 2015, 29 : 333 - 339
  • [25] Cardiac output monitoring in septic shock: evaluation of the third-generation Flotrac-VigileoA®
    Marque, Sophie
    Gros, Antoine
    Chimot, Loic
    Gacouin, Arnaud
    Lavoue, Sylvain
    Camus, Christophe
    Le Tulzo, Yves
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2013, 27 (03) : 273 - 279
  • [26] Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients
    De Backer, Daniel
    Marx, Gernot
    Tan, Andrew
    Junker, Christopher
    Van Nuffelen, Marc
    Huter, Lars
    Ching, Willy
    Michard, Frederic
    Vincent, Jean-Louis
    INTENSIVE CARE MEDICINE, 2011, 37 (02) : 233 - 240
  • [27] Variations in arterial blood pressure are associated with parallel changes in FlowTrac/Vigileo®-derived cardiac output measurements: a prospective comparison study
    Savvas Eleftheriadis
    Zisis Galatoudis
    Vasilios Didilis
    Ioannis Bougioukas
    Julika Schön
    Hermann Heinze
    Klaus-Ulrich Berger
    Matthias Heringlake
    Critical Care, 13
  • [28] Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients
    Daniel De Backer
    Gernot Marx
    Andrew Tan
    Christopher Junker
    Marc Van Nuffelen
    Lars Hüter
    Willy Ching
    Frédéric Michard
    Jean-Louis Vincent
    Intensive Care Medicine, 2011, 37 : 233 - 240
  • [29] Third-generation FloTrac/Vigileo does not reliably track changes in cardiac output induced by norepinephrine in critically ill patients
    Monnet, X.
    Anguel, N.
    Jozwiak, M.
    Richard, C.
    Teboul, J. -L.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 (04) : 615 - 622
  • [30] Cardiac output derived from arterial pressure waveform analysis without calibration vs. thermodilution in septic shock: evolving accuracy of software versions
    Slagt, Cornelis
    Beute, Jan
    Hoeksema, Martijn
    Malagon, Ignacio
    Mulder, Jan-Willem R.
    Groeneveld, Johan A. B.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (06) : 550 - 554