Arterial pressure waveform derived cardiac output FloTrac/Vigileo system (third generation software): comparison of two monitoring sites with the thermodilution cardiac output

被引:0
|
作者
Sumit Vasdev
Sandeep Chauhan
Minati Choudhury
Millind P. Hote
Madhur Malik
Usha Kiran
机构
[1] C N Centre,Department of Cardiac Anaesthesia
[2] All India Institute of Medical Sciences,Department of Cardiothoracic and Vascular Surgery
[3] All India Institute of Medical Sciences,undefined
来源
Journal of Clinical Monitoring and Computing | 2012年 / 26卷
关键词
Cardiac output; Pulmonary artery catheter; Thermodilution; Arterial waveform derived cardiac output; Non invasive cardiac output;
D O I
暂无
中图分类号
学科分类号
摘要
The present study was conducted to study the effect of monitoring site, radial or femoral, for arterial pressure waveform derived cardiac output using FloTrac/Vigileo system with third generation software version 3.02 during cardiac surgery. The cardiac output derived from the two sites was also compared to the pulmonary artery catheter (PAC) derived cardiac output to reevaluate the relation between them using the newer software. The effect of cardiopulmonary bypass (CPB) was also studied by doing the sub analysis before and after bypass. Forty patients undergoing coronary artery bypass surgery with cardiopulmonary bypass were enrolled in the study. Cardiac output derived from radial artery (RADCO), femoral artery (FEMCO) using FloTrac/Vigileo system with third generation software version 3.02 and cardiac output using pulmonary artery catheter (PACCO) at predefined nine time points were recorded. Three hundred and forty two cardiac output data triplets were analysed. The Bland–Altman analysis of RADCO and FEMCO revealed a mean bias of −0.28 with percentage error of 20%. The pre CPB precision of both RADCO and FEMCO was 1.25 times as that of PACCO. The post CPB precision of FEMCO was 1.2 times of PACCO while that of RADCO was 1.7 times of PACCO. The third generation of FloTrac/Vigileo system shows good correlation between the radial and femoral derived cardiac outputs in both pre and post bypass periods. The newer software correlates better to PAC derived cardiac output in the post bypass period for femoral artery than radial artery.
引用
收藏
页码:115 / 120
页数:5
相关论文
共 50 条
  • [1] Arterial pressure waveform derived cardiac output FloTrac/Vigileo system (third generation software): comparison of two monitoring sites with the thermodilution cardiac output
    Vasdev, Sumit
    Chauhan, Sandeep
    Choudhury, Minati
    Hote, Millind P.
    Malik, Madhur
    Kiran, Usha
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2012, 26 (02) : 115 - 120
  • [2] Cardiac output monitoring in septic shock: evaluation of the third-generation Flotrac-Vigileo®
    Sophie Marqué
    Antoine Gros
    Loic Chimot
    Arnaud Gacouin
    Sylvain Lavoué
    Christophe Camus
    Yves Le Tulzo
    Journal of Clinical Monitoring and Computing, 2013, 27 : 273 - 279
  • [3] Ability of the Third-Generation FloTrac/Vigileo Software to Track Changes in Cardiac Output in Cardiac Surgery Patients: A Polar Plot Approach
    Desebbe, Olivier
    Henaine, Roland
    Keller, Geoffray
    Koffel, Catherine
    Garcia, Hans
    Rosamel, Pascal
    Obadia, Jean-Francois
    Bastien, Olivier
    Lehot, Jean-Jacques
    Haftek, Marek
    Critchley, Lester A. H.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2013, 27 (06) : 1122 - 1127
  • [4] Assessment of a cardiac output device using arterial pulse waveform analysis, Vigileo™, in cardiac surgery compared to pulmonary arterial thermodilution
    Hamm, J. -B.
    Nguyen, B. -V.
    Kiss, G.
    Wargnier, J. -P.
    Jauffroy, A.
    Helaine, L.
    Arvieux, C. C.
    Gueret, G.
    ANAESTHESIA AND INTENSIVE CARE, 2010, 38 (02) : 295 - 301
  • [5] Improved Performance of the Fourth-Generation FloTrac/Vigileo System for Tracking Cardiac Output Changes
    Suehiro, Koichi
    Tanaka, Katsuaki
    Mikawa, Mika
    Uchihara, Yuriko
    Matsuyama, Taiki
    Matsuura, Tadashi
    Funao, Tomoharu
    Yamada, Tokuhiro
    Mori, Takashi
    Nishikawa, Kiyonobu
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2015, 29 (03) : 656 - 662
  • [6] Clinical evaluation of the FloTrac/Vigileo system and two established methods for continuous cardiac output monitoring in patients undergoing cardiac surgery
    D Button
    C Hofer
    Critical Care, 11 (Suppl 2):
  • [7] Continuous Arterial Pressure Waveform-Based Cardiac Output Using the FloTrac/Vigileo: A Review and Meta-analysis
    Mayer, Jochen
    Boldt, Joachim
    Poland, Reagan
    Peterson, Amanda
    Manecke, Gerard R.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2009, 23 (03) : 401 - 406
  • [8] A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients
    Jansen, JRC
    Schreuder, JJ
    Mulier, JP
    Smith, NT
    Settels, JJ
    Wesseling, KH
    BRITISH JOURNAL OF ANAESTHESIA, 2001, 87 (02) : 212 - 222
  • [9] The Vigileo-FloTrac™ System: Arterial Waveform Analysis for Measuring Cardiac Output and Predicting Fluid Responsiveness: A Clinical Review
    Suehiro, Koichi
    Tanaka, Katsuaki
    Matsuura, Tadashi
    Funao, Tomoharu
    Yamada, Tokuhiro
    Mori, Takashi
    Nishikawa, Kiyonobu
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2014, 28 (05) : 1361 - 1374
  • [10] Comparison of uncalibrated arterial waveform analysis in cardiac surgery patients with thermodilution cardiac output measurements
    Michael Sander
    Claudia D Spies
    Herko Grubitzsch
    Achim Foer
    Marcus Müller
    Christian von Heymann
    Critical Care, 10