Arterial pressure waveform derived cardiac output FloTrac/Vigileo system (third generation software): comparison of two monitoring sites with the thermodilution cardiac output

被引:0
作者
Sumit Vasdev
Sandeep Chauhan
Minati Choudhury
Millind P. Hote
Madhur Malik
Usha Kiran
机构
[1] C N Centre,Department of Cardiac Anaesthesia
[2] All India Institute of Medical Sciences,Department of Cardiothoracic and Vascular Surgery
[3] All India Institute of Medical Sciences,undefined
来源
Journal of Clinical Monitoring and Computing | 2012年 / 26卷
关键词
Cardiac output; Pulmonary artery catheter; Thermodilution; Arterial waveform derived cardiac output; Non invasive cardiac output;
D O I
暂无
中图分类号
学科分类号
摘要
The present study was conducted to study the effect of monitoring site, radial or femoral, for arterial pressure waveform derived cardiac output using FloTrac/Vigileo system with third generation software version 3.02 during cardiac surgery. The cardiac output derived from the two sites was also compared to the pulmonary artery catheter (PAC) derived cardiac output to reevaluate the relation between them using the newer software. The effect of cardiopulmonary bypass (CPB) was also studied by doing the sub analysis before and after bypass. Forty patients undergoing coronary artery bypass surgery with cardiopulmonary bypass were enrolled in the study. Cardiac output derived from radial artery (RADCO), femoral artery (FEMCO) using FloTrac/Vigileo system with third generation software version 3.02 and cardiac output using pulmonary artery catheter (PACCO) at predefined nine time points were recorded. Three hundred and forty two cardiac output data triplets were analysed. The Bland–Altman analysis of RADCO and FEMCO revealed a mean bias of −0.28 with percentage error of 20%. The pre CPB precision of both RADCO and FEMCO was 1.25 times as that of PACCO. The post CPB precision of FEMCO was 1.2 times of PACCO while that of RADCO was 1.7 times of PACCO. The third generation of FloTrac/Vigileo system shows good correlation between the radial and femoral derived cardiac outputs in both pre and post bypass periods. The newer software correlates better to PAC derived cardiac output in the post bypass period for femoral artery than radial artery.
引用
收藏
页码:115 / 120
页数:5
相关论文
共 53 条
[1]  
Swan HJC(1970)Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter N Engl J Med 283 447-451
[2]  
Ganz W(2006)Pulmonary artery catheter in anaesthesiology and intensive care Anaesthesist 55 713-730
[3]  
Forrester J(1985)Complications of right heart catheterization. A prospective autopsy study Chest 88 567-572
[4]  
De Waal EEC(2003)Increased risk associated with pulmonary artery catheterization in the medical intensive care unit J Crit Care 18 166-171
[5]  
De Rossi L(1987)Death by pulmonary artery flow-directed catheter. Time for a moratorium? Chest 92 727-731
[6]  
Buhre W(2002)Minimally invasive hemodynamic monitoring for the intensivist: current and emerging technology Crit Care Med 30 2338-2345
[7]  
Connors AF(1985)The pressure dependent dynamic elasticity of 35 thoracic and 16 abdominal human aortas in vitro described by a five-component model J Biomech 18 613-620
[8]  
Castele RJ(2007)Comparison of FloTrac cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurements Eur J Anaesthesiol 24 832-839
[9]  
Farhat NZ(2007)Clinical evaluation of the FloTrac/Vigileo system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery Br J Anaesth 99 329-336
[10]  
Peters SG(2007)Evaluation of a new arterial pressure-based cardiac output device requiring no external calibration BMC Anesthesiol 7 9-301