The use of reference image criteria in X-ray diagnostics: an application for the optimisation of lumbar spine radiographs

被引:0
|
作者
A. Almén
A. Tingberg
J. Besjakov
S. Mattsson
机构
[1] Malmö University Hospital,Department of Radiation Physics
[2] Swedish Radiation Protection Authority,Department of Radiology
[3] Malmö University Hospital,undefined
来源
European Radiology | 2004年 / 14卷
关键词
X-ray image; Image quality; Clinical study; Diagnostic radiology;
D O I
暂无
中图分类号
学科分类号
摘要
To ensure that sufficient image quality is obtained in diagnostic radiology, the image quality of clinical radiographs has to be evaluated. We present two methods herein for evaluating antero-posterior (AP) radiographs of the lumbar spine. One was using image criteria, including six anatomical details (absolute method). In the other, the visibility of anatomical details relative to a reference radiograph was evaluated (visual grading analysis). In total, 14 technique groups were evaluated. The technique groups differed in tube voltage and detector system characteristics. Six different gradients of the H&D curves were simulated. The visual grading analysis showed larger differences in image quality compared with the absolute method. The influence on the image quality due to a variation in tube voltage was easier to detect than the influence on the image quality from the detector characteristics. The visibility of the anatomical details was significantly dependent on the location in the spine. The visual grading analysis was found to be the preferable evaluation method in studies such as the present; however, it is necessary to guide and train the observer before the evaluation is performed.
引用
收藏
页码:1561 / 1567
页数:6
相关论文
共 16 条
  • [1] The use of reference image criteria in X-ray diagnostics:: an application for the optimisation of lumbar spine radiographs
    Almén, A
    Tingberg, A
    Besjakov, J
    Mattsson, S
    EUROPEAN RADIOLOGY, 2004, 14 (09) : 1561 - 1567
  • [2] A Comparison of Image Enhancement Methods for Lumbar Spine X-ray Image
    Saenpaen, Jennarong
    Arwatchananukul, Sujitra
    Aunsri, Nattapol
    2018 15TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), 2018, : 798 - 801
  • [3] Evaluation of spine boards for X-ray diagnostics.
    Linsenmaier, U
    Krötz, M
    Kanz, KG
    Russ, W
    Papst, E
    Rieger, J
    Mutscher, W
    Pfeifer, KJ
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (11): : 1041 - 1047
  • [4] Effect of x-ray tube potential on image quality and patient dose for lumbar spine computed radiography examinations
    Brindhaban A.
    Al Khalifah K.
    Al Wathiqi G.
    Al Ostath H.
    Australasian Physics & Engineering Sciences in Medicine, 2005, 28 (4): : 216 - 222
  • [5] X-ray Image Processing Methods in Minimally Invasive Spine Surgery
    Zhang, Huanbo
    Shen, Xianglin
    Dong, Liang
    Miao, Sheng
    Ma, Qin
    Yan Wang
    2016 8TH INTERNATIONAL CONFERENCE ON INTELLIGENT HUMAN-MACHINE SYSTEMS AND CYBERNETICS (IHMSC), VOL. 2, 2016, : 296 - 299
  • [6] Spine X-ray Image Segmentation Based on Transformer and Adaptive Optimized Postprocessing
    Zhang, Lingrong
    Yang, Jinglin
    Liu, Dong
    Zhang, Feng
    Nie, Sibo
    Tan, Yuchen
    Guo, Taipeng
    2022 2ND IEEE INTERNATIONAL CONFERENCE ON SOFTWARE ENGINEERING AND ARTIFICIAL INTELLIGENCE (SEAI 2022), 2022, : 88 - 92
  • [7] CT x-ray tube voltage optimisation and image reconstruction evaluation using visual grading analysis
    Zheng, Xiaoming
    Kim, Ted Myeongsoo
    Davidson, Rob
    Lee, Seongju
    Shin, Cheongil
    Yang, Sook
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [8] AN APPLICATION OF COMPUTER IMAGE-PROCESSING TO THE CLARIFICATION OF X-RAY IMAGES OF ENERGY DISPERSIVE-X-RAY SPECTROMETRY
    FUKAMACHI, M
    KIMURA, T
    ISIJ INTERNATIONAL, 1990, 30 (07) : 516 - 519
  • [9] Calibration and validation of a voxel phantom for use in the Monte Carlo modeling and optimisation of X-ray imaging systems
    Dance, DR
    McVey, G
    Sadborg, M
    Persliden, J
    Carlsson, GA
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 548 - 559
  • [10] Impact on image quality when a variety of X-ray source detector distances are considered for the arthritic cervical spine
    Joyce, Maria
    Brennan, Patrick C.
    Rainford, Louise A.
    Last, Jason
    Ryan, John T.
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913