DER-01M Miniature Portable X-Ray Dosimeter for Monitoring Dose and Dose Rate in X-Ray Diagnosis

被引:0
|
作者
L. V. Vladimirov
A. A. Kozlov
机构
[1] Scientific-Research Institute of Introscopy,Spektr Scientific
关键词
Dose Rate; Miniature Portable;
D O I
10.1023/B:BIEN.0000012500.40812.65
中图分类号
学科分类号
摘要
引用
收藏
页码:295 / 298
页数:3
相关论文
共 50 条
  • [31] Portable x-ray fluorescence spectrometer with a pyroelectric x-ray generator
    Ida, H
    Kawai, J
    X-RAY SPECTROMETRY, 2005, 34 (03) : 225 - 229
  • [32] Miniature X-Ray Sources
    Gorecka-Drzazga, Anna
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2017, 26 (01) : 295 - 302
  • [33] MINIATURE X-RAY GENERATORS
    GRALENSK.NM
    MATERIALS EVALUATION, 1971, 29 (02) : A24 - &
  • [34] A CYTOGENETIC MODEL AS DOSIMETER FOR ABSORBED DOSE FOLLOWING X-RAY OR GAMMA-RAY RADIATION ACCIDENTS
    MINNAAR, PC
    JANSEN, S
    MEDICAL PHYSICS, 1987, 14 (04) : 712 - 712
  • [35] Monitoring the X-Ray Variability of Bright X-Ray Sources in M33
    Kyer, Rebecca
    Albrecht, Shelby
    Williams, Benjamin F.
    Hinton, Kyros
    Binder, Breanna
    Lazzarini, Margaret
    Garofali, Kristen
    Lehmer, Bret
    Eracleous, Michael
    Plucinsky, Paul P.
    Antoniou, Vallia
    ASTROPHYSICAL JOURNAL, 2024, 961 (02):
  • [36] The ID-03 X-ray dosimeter for monitoring radiation parameters of X-ray apparatuses in the roentgenographic mode
    Vladimirov L.V.
    Kozlov A.A.
    Biomedical Engineering, 2002, 36 (5) : 261 - 263
  • [37] Quantitative radiography of welds - dose rate, dose and contrast of x-ray equipment and films
    Holmstroem, Johan-Edvin
    Materialpruefung/Materials Testing, 1995, 37 (03): : 64 - 68
  • [38] THE UNIT OF X-RAY DOSE AND ITS REALISATION .1. THE STANDARDISATION OF X-RAY DOSEMETERS
    SMITH, EE
    BRITISH JOURNAL OF RADIOLOGY, 1955, 28 (336): : 662 - 669
  • [39] EFFECT OF DOSE-RATE AND FRACTIONATION OF X-RAY DOSE ON ACUTE LETHALITY IN MICE
    BROWN, JAH
    CORP, MJ
    WESTGARTH, DR
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY AND RELATED STUDIES IN PHYSICS CHEMISTRY AND MEDICINE, 1960, 2 (04): : 371 - 381
  • [40] A Preliminary Study on Low-dose X-ray Imaging Using Parametric X-ray
    Sakae, Toshiro
    Hayakawa, Yasushi
    Takahashi, Yumiko
    Kuwada, Takao
    Nakao, Keisuke
    Nogami, Kyoko
    Inagaki, Manabu
    Tanaka, Toshinari
    Sato, Isamu
    Hirayama, Katsunori
    Sekiya, Kotarou
    Kaneda, Takashi
    Suemitsu, Masaaki
    Okada, Hiroyuki
    Yamamoto, Hirotsugu
    Hata, Saya
    Akimoto, Yoshiaki
    Fukumoto, Masahiko
    Makimura, Masaharu
    JOURNAL OF HARD TISSUE BIOLOGY, 2011, 20 (01) : 31 - 35