Trace determination of triclosan and triclocarban in environmental water samples with ionic liquid dispersive liquid-phase microextraction prior to HPLC–ESI-MS–MS

被引:0
|
作者
Ru-Song Zhao
Xia Wang
Jing Sun
Shan-Shan Wang
Jin-Peng Yuan
Xi-Kui Wang
机构
[1] Shandong Academy of Sciences,Analysis and Test Center
[2] Shandong Institute of light industry,undefined
来源
Analytical and Bioanalytical Chemistry | 2010年 / 397卷
关键词
Triclosan; Triclocarban; Ionic liquid dispersive liquid phase microextraction; High performance liquid phase chromatography–electrospray tandem mass spectrometry;
D O I
暂无
中图分类号
学科分类号
摘要
A novel and environmentally friendly microextraction method, termed ionic liquid dispersive liquid-phase microextraction (IL-DLPME), has been developed for rapid enrichment of triclosan and triclocarban before analysis by high-performance liquid phase chromatography–electrospray tandem mass spectrometry (HPLC–ESI-MS–MS). Instead of using toxic organic solvents, an ionic liquid was used as a green extraction solvent. This also avoided the instability of the suspending drop in single-drop liquid-phase microextraction, and the heating and cooling step in temperature-controlled ionic liquid dispersive liquid phase microextraction. Factors that may affect the enrichment efficiency, for example volume of ionic liquid, type and volume of dispersive solvent, pH, extraction time, and NaCl content were investigated in detail and optimized. Under optimum conditions, linearity of the method was observed over the range 0.2–12 μg L−1 for triclocarban and 1–60 μg L−1 for triclosan with correlation coefficients ranging from 0.9980 to 0.9990, respectively. The sensitivity of the proposed method was found to be excellent, with limits of detection in the range 0.040–0.58 μg L−1 and precision in the range 7.0–8.8% (RSD, n = 5). This method has been successfully used to analyze real environmental water samples and satisfactory results were achieved. Average recoveries of spiked compounds were in the range 70.0–103.5%. All these results indicated that the developed method would be a green method for rapid determination of triclosan and triclocarban at trace levels in environmental water samples.
引用
收藏
页码:1627 / 1633
页数:6
相关论文
共 50 条
  • [22] Determination of triclosan, triclocarban and methyl-triclosan in aqueous samples by dispersive liquid-liquid microextraction combined with rapid liquid chromatography
    Guo, Jie-Hong
    Li, Xing-Hong
    Cao, Xue-Li
    Li, Yan
    Wang, Xi-Zhi
    Xu, Xiao-Bai
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (15) : 3038 - 3043
  • [23] Isotope dilution determination for the trace level of 4(5)-methylimidazole in beverages using dispersive liquid-liquid microextraction coupled with ESI-HPLC-MS/MS
    Feng, Ting-Ting
    Wu, Jian-Hai
    Liang, Xu
    Du, Ming
    Qin, Lei
    Xu, Xian-Bing
    FOOD CHEMISTRY, 2018, 245 : 687 - 691
  • [24] Combination of ionic liquid dispersive liquid-phase microextraction and high performance liquid chromatography for the determination of triazine herbicides in water samples
    Zhou, Qing-Xiang
    Gao, Yuan-Yuan
    CHINESE CHEMICAL LETTERS, 2014, 25 (05) : 745 - 748
  • [25] Combination of ionic liquid dispersive liquid-phase microextraction and high performance liquid chromatography for the determination of triazine herbicides in water samples
    Qing-Xiang Zhou
    Yuan-Yuan Gao
    Chinese Chemical Letters, 2014, 25 (05) : 745 - 748
  • [26] Dynamic liquid-phase microextraction with HPLC for the determination of phoxin in water samples
    Liang, P
    Xu, J
    Guo, L
    Song, F
    JOURNAL OF SEPARATION SCIENCE, 2006, 29 (03) : 366 - 370
  • [27] Homogenous dispersive solid phase extraction combined with ionic liquid based-dispersive liquid–liquid microextraction of gentamicin and streptomycin from milk prior to HPLC-MS/MS analysis
    Abolghasem Jouyban
    Mahboob Nemati
    Mir Ali Farajzadeh
    Jafar Soleymani
    Mohammad Reza Afshar Mogaddam
    Journal of the Iranian Chemical Society, 2022, 19 : 4309 - 4316
  • [28] Rapid determination of bisphenol A in drinking water using dispersive liquid-phase microextraction with in situ derivatization prior to GC-MS
    Wang, Xia
    Diao, Chun-Peng
    Zhao, Ru-Song
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (01) : 154 - 159
  • [29] Sensitive determination of amide herbicides in environmental water samples by a combination of solid-phase extraction and dispersive liquid-liquid microextraction prior to GC-MS
    Zhao, Ru-Song
    Diao, Chun-Peng
    Chen, Qing-Feng
    Wang, Xia
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (07) : 1069 - 1074
  • [30] Rapid Determination of DDT and Its Metabolites in Environmental Water Samples with Mixed Ionic Liquids Dispersive Liquid–Liquid Microextraction Prior to HPLC-UV
    Xia Wang
    Qing-Cai Xu
    Chuan-Ge Cheng
    Ru-Song Zhao
    Chromatographia, 2012, 75 : 1081 - 1085