The Search Coil Magnetometer for THEMIS

被引:0
作者
A. Roux
O. Le Contel
C. Coillot
A. Bouabdellah
B. de la Porte
D. Alison
S. Ruocco
M. C. Vassal
机构
[1] Centre d’étude des Environnements Terrestre et Planétaires (CETP),
[2] 3D Plus,undefined
来源
Space Science Reviews | 2008年 / 141卷
关键词
Search-coil magnetometer; Magnetospheric mission; Substorm physics;
D O I
暂无
中图分类号
学科分类号
摘要
THEMIS instruments incorporate a tri-axial Search Coil Magnetometer (SCM) designed to measure the magnetic components of waves associated with substorm breakup and expansion. The three search coil antennas cover the same frequency bandwidth, from 0.1 Hz to 4 kHz, in the ULF/ELF frequency range. They extend, with appropriate Noise Equivalent Magnetic Induction (NEMI) and sufficient overlap, the measurements of the fluxgate magnetometers. The NEMI of the searchcoil antennas and associated pre-amplifiers is smaller than 0.76 pT \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$/\sqrt{\mathrm{Hz}}$\end{document} at 10 Hz. The analog signals produced by the searchcoils and associated preamplifiers are digitized and processed inside the Digital Field Box (DFB) and the Instrument Data Processing Unit (IDPU), together with data from the Electric Field Instrument (EFI). Searchcoil telemetry includes waveform transmission, FFT processed data, and data from a filter bank. The frequency range covered depends on the available telemetry. The searchcoils and their three axis structures have been precisely calibrated in a calibration facility, and the calibration of the transfer function is checked on board, usually once per orbit. The tri-axial searchcoils implemented on the five THEMIS spacecraft are working nominally.
引用
收藏
页码:265 / 275
页数:10
相关论文
共 100 条
  • [1] Angelopoulos V.(2008)The THEMIS mission Space Sci. Rev. 13 320-326
  • [2] Bozorth R.M.(1942)Demagnetizing factors of rods J. Appl. Phys. 4 2499-2508
  • [3] Chapin D.M.(1992)Magnetic reconnection in electron dynamics Phys. Fluids B 5 1-4
  • [4] Bulanov S.V.(2007)Improvements on the design of search coil magnetometer for space experiments Sens. Lett. 79 107-136
  • [5] Pegoraro F.(1997)The cluster Spatio-temporal Analysis of Field Fluctuations (STAFF) experiment Space Sci. Rev. 21 437-456
  • [6] Sakharov A.S.(2003)STAFF team, First results obtained by the Cluster STAFF experiment Ann. Geophys. 39 535-563
  • [7] Coillot C.(2008)The THEMIS digital fields board Space Sci. Rev. 97 1461-77
  • [8] Moutoussamy J.(2008)First results of THEMIS Search Coil Magnetometers (SCM) Space Sci. Rev. 21 73-357
  • [9] Leroy P.(2008)The THEMIS magnetic cleanliness program Space Sci. Rev. 67 351-undefined
  • [10] Chanteur G.(2001)Current controversies in magnetospheric physics Rev. Geophys. 96 17,697-undefined