Determination of trace elements in zeolites by laser ablation ICP-MS

被引:0
作者
C. Pickhardt
I. B. Brenner
J. S. Becker
H.-J. Dietze
机构
[1] Zentralabteilung für Chemische Analysen,
[2] Forschungszentrum Jülich GmbH,undefined
[3] D-52425 Jülich,undefined
[4] Germany,undefined
[5] 9 Dishon Street,undefined
[6] Malkha BGU-EAL,undefined
[7] 96956 Jerusalem,undefined
[8] Israel,undefined
来源
Fresenius' Journal of Analytical Chemistry | 2000年 / 368卷
关键词
Zeolite; Inductively Couple Plasma Mass Spectrometry; Laser Ablation; Aluminosilicate; Trace Element Concentration;
D O I
暂无
中图分类号
学科分类号
摘要
Laser ablation inductively coupled plasma mass spectrometry using a quadrupole-based mass spectrometer (LA-ICP-QMS) was applied for the analysis of powdered zeolites (microporous aluminosilicates) used for clean-up procedures. For the quantitative determination of trace element concentrations three geological reference materials, granite NIM-G, lujavrite NIM-L and syenite NIM-S, from the National Institute for Metallurgy (South Africa) with a matrix composition corresponding to the zeolites were employed. Both the zeolites and reference materials were fused with a lithium borate mixture to increase the homogeneity and to eliminate mineralogical effects. In order to compare two different approaches for the quantification of analytical results in LA-ICP-MS relative sensitivity coefficients (RSCs) of chemical elements and calibration curves were measured using the geostandards. The experimentally obtained RSCs are in the range of 0.2-6 for all elements of interest. Calibration curves for trace elements were measured without and with Li or Ti as internal standard element. With a few exceptions the regression coefficients of the calibration curves are better than 0.993 with internal standardization. NIM-G granite reference material was employed to evaluate the accuracy of the technique. Therefore, the measured concentrations were corrected with RSCs which were determined using lujavrite reference material NIM-L. This quantification method provided analytical results with deviations of 1–11% from the recommended and proposed values in granite reference material NIM-G, except for Co, Cs, La and Tb. The relative standard deviation (RSD) of the determination of the trace element concentration (n = 5) is about 1% to 6% using Ti as internal standard element. Detection limits of LA-ICP-QMS in the lower μg/g range (from 0.03 μg/g for Lu, Ta and Th to 7.3 μg/g for Cu, with the exception of La) have been achieved for all elements of interest. Under the laser ablation conditions employed (λ: 266 nm, repetition frequency: 10 Hz, pulse energy: 10 mJ, laser power density: 6 × 109 W/cm2) fractionation effects of the determined elements relative to the internal standard element Ti were not observed.
引用
收藏
页码:79 / 87
页数:8
相关论文
共 50 条
  • [41] Aerosol extraction and direct laser ablation ICP-MS analysis of the fine and ultrafine fractions of regolith
    Morris, Paul A.
    Christ, Alex
    Mikucki, Edward J.
    GEOCHEMISTRY-EXPLORATION ENVIRONMENT ANALYSIS, 2020, 20 (03) : 280 - 298
  • [42] Low-pressure helium ICP-MS for trace analysis
    Hayashi, H
    Hiraide, M
    BUNSEKI KAGAKU, 2004, 53 (08) : 793 - 804
  • [43] SAMPLE PREPARATION FOR DETERMINATION OF RARE EARTH ELEMENTS IN GEOLOGICAL SAMPLES BY ICP-MS: A CRITICAL REVIEW
    Pinto, Frederico Garcia
    Escalfoni Junior, Rainerio
    Saint'Pierre, Tatiana Dillenburg
    ANALYTICAL LETTERS, 2012, 45 (12) : 1537 - 1556
  • [44] Determination of uranium, thorium and rare-earth elements in zircon samples using ICP-MS
    Singh, A. K.
    Padmasubashini, V.
    Gopal, Leela
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2012, 294 (01) : 19 - 25
  • [45] Analytical considerations in the determination of uranium isotope ratios in solid uranium materials using laser ablation multi-collector ICP-MS
    Krachler M.
    Varga Z.
    Nicholl A.
    Mayer K.
    Analytica Chimica Acta: X, 2019, 2
  • [46] ESSENTIAL AND TOXIC ELEMENTS IN DIETARY SUPPLEMENTS DETERMINED BY ICP-MS
    Mihaltan, Alin Ironim
    Naghiu, Anca
    Tanaselia, Claudiu
    Frentiu, Tiberiu
    Cimpoiu, Claudia
    STUDIA UNIVERSITATIS BABES-BOLYAI CHEMIA, 2012, 57 (01): : 47 - 56
  • [47] ICP-MS laser ablation oak wood metals wood standard semi-quantitative analysis
    Alteyrac, J
    Augagneur, S
    Medina, B
    Vivas, N
    Glories, Y
    ANALUSIS, 1995, 23 (10) : 523 - 526
  • [48] Speciation of iodine-containing proteins in Nori seaweed by gel electrophoresis laser ablation ICP-MS
    Romaris-Hortas, V.
    Bianga, J.
    Moreda-Pineiro, A.
    Bermejo-Barrera, P.
    Szpunar, J.
    TALANTA, 2014, 127 : 175 - 180
  • [49] U-Pb dating of zircon by laser ablation ICP-MS: recent improvements and new insights
    Kooijman, Ellen
    Berndt, Jasper
    Mezger, Klaus
    EUROPEAN JOURNAL OF MINERALOGY, 2012, 24 (01) : 5 - 21
  • [50] Laser ablation of titanium nitride coated on silicon wafer substrate for depth profiling using ICP-MS
    Lee, Jin Sook
    Lim, H. B.
    APPLIED SURFACE SCIENCE, 2015, 327 : 483 - 489