Determination of trace elements in zeolites by laser ablation ICP-MS

被引:0
|
作者
C. Pickhardt
I. B. Brenner
J. S. Becker
H.-J. Dietze
机构
[1] Zentralabteilung für Chemische Analysen,
[2] Forschungszentrum Jülich GmbH,undefined
[3] D-52425 Jülich,undefined
[4] Germany,undefined
[5] 9 Dishon Street,undefined
[6] Malkha BGU-EAL,undefined
[7] 96956 Jerusalem,undefined
[8] Israel,undefined
来源
Fresenius' Journal of Analytical Chemistry | 2000年 / 368卷
关键词
Zeolite; Inductively Couple Plasma Mass Spectrometry; Laser Ablation; Aluminosilicate; Trace Element Concentration;
D O I
暂无
中图分类号
学科分类号
摘要
Laser ablation inductively coupled plasma mass spectrometry using a quadrupole-based mass spectrometer (LA-ICP-QMS) was applied for the analysis of powdered zeolites (microporous aluminosilicates) used for clean-up procedures. For the quantitative determination of trace element concentrations three geological reference materials, granite NIM-G, lujavrite NIM-L and syenite NIM-S, from the National Institute for Metallurgy (South Africa) with a matrix composition corresponding to the zeolites were employed. Both the zeolites and reference materials were fused with a lithium borate mixture to increase the homogeneity and to eliminate mineralogical effects. In order to compare two different approaches for the quantification of analytical results in LA-ICP-MS relative sensitivity coefficients (RSCs) of chemical elements and calibration curves were measured using the geostandards. The experimentally obtained RSCs are in the range of 0.2-6 for all elements of interest. Calibration curves for trace elements were measured without and with Li or Ti as internal standard element. With a few exceptions the regression coefficients of the calibration curves are better than 0.993 with internal standardization. NIM-G granite reference material was employed to evaluate the accuracy of the technique. Therefore, the measured concentrations were corrected with RSCs which were determined using lujavrite reference material NIM-L. This quantification method provided analytical results with deviations of 1–11% from the recommended and proposed values in granite reference material NIM-G, except for Co, Cs, La and Tb. The relative standard deviation (RSD) of the determination of the trace element concentration (n = 5) is about 1% to 6% using Ti as internal standard element. Detection limits of LA-ICP-QMS in the lower μg/g range (from 0.03 μg/g for Lu, Ta and Th to 7.3 μg/g for Cu, with the exception of La) have been achieved for all elements of interest. Under the laser ablation conditions employed (λ: 266 nm, repetition frequency: 10 Hz, pulse energy: 10 mJ, laser power density: 6 × 109 W/cm2) fractionation effects of the determined elements relative to the internal standard element Ti were not observed.
引用
收藏
页码:79 / 87
页数:8
相关论文
共 50 条
  • [21] The coupling of laser ablation/ICP-AES and ICP-MS spectrometry: A multiple applications tool
    Gilon, N.
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2005, 50 (05): : 240 - 254
  • [22] Towards a protocol for the trace element analysis of glass from rhyolitic shards in tephra deposits by laser ablation ICP-MS
    Pearce, Nicholas J. G.
    JOURNAL OF QUATERNARY SCIENCE, 2014, 29 (07) : 627 - 640
  • [23] Application of laser ablation inductively coupled mass spectrometry (LA-ICP-MS) for the determination of major, minor, and trace elements in bark samples
    U. Narewski
    G. Werner
    H. Schulz
    C. Vogt
    Fresenius' Journal of Analytical Chemistry, 2000, 366 : 167 - 170
  • [24] New laser ablation system for quantitative analysis of solid samples by ICP-MS
    Ishida, T
    Akiyoshi, T
    Sakashita, A
    Kinoshiro, S
    Fujimoto, K
    Chino, A
    BUNSEKI KAGAKU, 2006, 55 (04) : 229 - 236
  • [25] Apatite fission-track chronometry using laser ablation ICP-MS
    Hasebe, N
    Barbarand, J
    Jarvis, K
    Carter, A
    Hurford, AJ
    CHEMICAL GEOLOGY, 2004, 207 (3-4) : 135 - 145
  • [26] Progress in the Application of Laser Ablation ICP-MS to Surface Microanalysis in Material Science
    Zhang Yong
    Jia Yun-hai
    Chen Ji-wen
    Shen Xue-jing
    Liu Ying
    Zhao Lei
    Li Dong-ling
    Hang Peng-cheng
    Zhao Zhen
    Fan Wan-lun
    Wang Hai-zhou
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (08) : 2238 - 2243
  • [27] Opportunities and challenges of isotopic analysis by laser ablation ICP-MS in biological studies
    Lobo, Lara
    Pereiro, Rosario
    Fernandez, Beatriz
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2018, 105 : 380 - 390
  • [28] Single-cell ICP-MS to address the role of trace elements at a cellular level
    Silva, Ana Beatriz Santos da
    Arruda, Marco Aurelio Zezzi
    JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 2023, 75
  • [29] Evaluation of the digestion capability of ammonium bifluoride for the determination of major and trace elements in Ti-rich minerals by ICP-MS
    Liu, Hong
    Hu, Zhaochu
    He, Tao
    Zhang, Wen
    Zong, Keqing
    Luo, Tao
    Qiu, Xiaoyun
    Gao, Yang
    Li, Mufei
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (05) : 1146 - 1154
  • [30] Capabilities of femtosecond laser ablation ICP-MS for the major, minor, and trace element analysis of high alloyed steels and super alloys
    Wiltsche, Helmar
    Guenther, Detlef
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (06) : 2167 - 2174