Determination of trace elements in zeolites by laser ablation ICP-MS

被引:0
|
作者
C. Pickhardt
I. B. Brenner
J. S. Becker
H.-J. Dietze
机构
[1] Zentralabteilung für Chemische Analysen,
[2] Forschungszentrum Jülich GmbH,undefined
[3] D-52425 Jülich,undefined
[4] Germany,undefined
[5] 9 Dishon Street,undefined
[6] Malkha BGU-EAL,undefined
[7] 96956 Jerusalem,undefined
[8] Israel,undefined
关键词
Zeolite; Inductively Couple Plasma Mass Spectrometry; Laser Ablation; Aluminosilicate; Trace Element Concentration;
D O I
暂无
中图分类号
学科分类号
摘要
Laser ablation inductively coupled plasma mass spectrometry using a quadrupole-based mass spectrometer (LA-ICP-QMS) was applied for the analysis of powdered zeolites (microporous aluminosilicates) used for clean-up procedures. For the quantitative determination of trace element concentrations three geological reference materials, granite NIM-G, lujavrite NIM-L and syenite NIM-S, from the National Institute for Metallurgy (South Africa) with a matrix composition corresponding to the zeolites were employed. Both the zeolites and reference materials were fused with a lithium borate mixture to increase the homogeneity and to eliminate mineralogical effects. In order to compare two different approaches for the quantification of analytical results in LA-ICP-MS relative sensitivity coefficients (RSCs) of chemical elements and calibration curves were measured using the geostandards. The experimentally obtained RSCs are in the range of 0.2-6 for all elements of interest. Calibration curves for trace elements were measured without and with Li or Ti as internal standard element. With a few exceptions the regression coefficients of the calibration curves are better than 0.993 with internal standardization. NIM-G granite reference material was employed to evaluate the accuracy of the technique. Therefore, the measured concentrations were corrected with RSCs which were determined using lujavrite reference material NIM-L. This quantification method provided analytical results with deviations of 1–11% from the recommended and proposed values in granite reference material NIM-G, except for Co, Cs, La and Tb. The relative standard deviation (RSD) of the determination of the trace element concentration (n = 5) is about 1% to 6% using Ti as internal standard element. Detection limits of LA-ICP-QMS in the lower μg/g range (from 0.03 μg/g for Lu, Ta and Th to 7.3 μg/g for Cu, with the exception of La) have been achieved for all elements of interest. Under the laser ablation conditions employed (λ: 266 nm, repetition frequency: 10 Hz, pulse energy: 10 mJ, laser power density: 6 × 109 W/cm2) fractionation effects of the determined elements relative to the internal standard element Ti were not observed.
引用
收藏
页码:79 / 87
页数:8
相关论文
共 50 条
  • [1] Determination of trace elements in zeolites by laser ablation ICP-MS
    Pickhardt, C
    Brenner, IB
    Becker, JS
    Dietze, HJ
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (01): : 79 - 87
  • [2] Femtosecond laser ablation ICP-MS analysis of trace elements in solids
    Poitrasson, F
    Freydier, R
    Mao, X
    Mao, SS
    Russo, RE
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2005, 69 (10) : A54 - A54
  • [3] ICP-MS determination of trace elements in fish
    Chamberlain, I
    Adams, K
    Le, S
    ATOMIC SPECTROSCOPY, 2000, 21 (04) : 118 - 122
  • [4] High resolution analysis of trace elements in corals by laser ablation ICP-MS
    Sinclair, DJ
    Kinsley, LPJ
    McCulloch, MT
    GEOCHIMICA ET COSMOCHIMICA ACTA, 1998, 62 (11) : 1889 - 1901
  • [5] Determination of trace elements in methyl alcohol by ICP-MS
    Yan, S.-Y. (ysy2656@163.com), 1600, Chinese Society for Mass Spectrometry (35):
  • [6] Determination of Trace Elements in Super Alloy by ICP-MS
    Jingyu Hu
    Haizhou Wang
    Microchimica Acta, 2001, 137 : 149 - 155
  • [7] Determination of trace elements in super alloy by ICP-MS
    Hu, JY
    Wang, HZ
    MIKROCHIMICA ACTA, 2001, 137 (3-4) : 149 - 155
  • [8] ICP-MS for the determination of trace elements in clinical samples
    St'astná, M
    Nemcová, I
    Zyka, J
    ANALYTICAL LETTERS, 1999, 32 (13) : 2531 - 2543
  • [9] Determination of major and trace elements in sphalerite using laser ablation double focusing sector field ICP-MS
    Axelsson, MD
    Rodushkin, I
    JOURNAL OF GEOCHEMICAL EXPLORATION, 2001, 72 (02) : 81 - 89
  • [10] Trace element determination of single fluid inclusions in quartz by laser ablation ICP-MS
    McCandless, TE
    Lajack, DJ
    Ruiz, J
    Ghazi, AM
    GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 1997, 21 (02): : 279 - 287