Determination of coronary calcium with Multi-slice Spiral Computed Tomography: a comparative study with Electron-beam CT

被引:0
作者
Andreas Knez
Christoph Becker
Alexander Becker
Alexander Leber
Carl White
Maximilian Reiser
Gerhard Steinbeck
机构
[1] Ludwig-Maximilians-University Munich,Department of Cardiology
[2] Ludwig-Maximilians-University Munich,Department of Clinical Radiology
[3] University of Minnesota,Division of Cardiology
来源
The International Journal of Cardiovascular Imaging | 2002年 / 18卷
关键词
coronary atherosclerosis; coronary calcification; cardiac imaging; computed tomography;
D O I
暂无
中图分类号
学科分类号
摘要
Electron-beam Computed Tomography (EBCT) has been used for years to quantify coronary artery calcification as a marker of coronary atherosclerosis. The aim of this study was to determine the diagnostic accuracy of a new scanner, the Multi-slice Spiral CT (MSCT), for the assessment of coronary calcification and to compare this new technique to EBCT. The study population consisted of 99 male patients, aged 60 ± 10 years with suspected or known coronary artery disease. With EBCT 40 axial slices, ECG-triggered (scan time = 100 ms, slice thickness = 3 mm), were acquired in one breath-hold (35 ± 5 s). For MSCT simultaneous acquisition of four axial slices (scan time = 250 ms, slice thickness = 2.5 mm), allowed the entire heart (48 slices) to be covered in one breath-hold of 25 ± 5 s. For quantification of coronary calcium the Volumetric Calcium Score (VCS) was calculated. There was an excellent correlation for the VCS (r = 0.994, p = 0.01, mean difference = 97 ± 115) between both scanners. Comparison of low (1–100), moderate (101–400), high (401–1000) and very high score values (>1000) showed no significant differences. The number of calcified lesions and densities were statistically not different. Mean variability of the two scans was 17%. The MSCT scanner is equivalent to EBCT for the determination and quantification of coronary calcium and can therefore be used for calcium screening. With application of the spiral mode technique further improvement in variability can be expected, thus allowing for follow-up studies to determine progression or regression of atherosclerosis with high accuracy.
引用
收藏
页码:295 / 303
页数:8
相关论文
共 87 条
  • [1] Downs JR(1994)Registration procedures, event rates, and case-fatality rates in 38 populations from 21 countries in four continents Circulation 90 583-612
  • [2] Clearfield M(1998)Primary prevention of acute coronary events with lovastatin in men and women with average cholesterol levels: results of AFCAPs/Tex-CAPS: Air Force/Texas Coronary Atherosclerosis Prevention Study JAMA 279 1615-1622
  • [3] Weis S(1995)For the West of Scotland Coronary Prevention Study Group: Prevention of coronary heart disease with pravastatin in men with hypercholesterolemia New Engl J Med 333 1301-1307
  • [4] Sheperd J(1994)Coronary artery calcification; assessment with electron beam CT and histomonomorphic correlation Radiology 192 619-623
  • [5] Cobbe SM(1987)A logical approach to screening for coronary artery disease Ann Intern Med 106 846-852
  • [6] Ford I(1995)Coronary artery calcium area by electron-beam computed tomography and coronary atherosclerotic plaque area. A histopathologic correlative study Circulation 92 2157-2162
  • [7] Mautner GC(1995)Calcification of coronary arteries: detection and quantification with double-helix CT Radiology 197 779-783
  • [8] Mautner SL(2000)Helical and single-slice conventional CT versus electron beam CT for the quantification of coronary artery calcification Am J Roentgenol 174 543-547
  • [9] Froehlich J(2000)Evaluation of subsecond gated helical CT for quantification of coronary artery calcium and comparison with electron beam CT Am J Roentgenol 174 915-921
  • [10] Detrano R(2000)Cardiac imaging by means of electrocardiographically gated multislice spiral CT: initial experience Radiology 217 564-571