The pressure exerted on the tongue during intubation with simultaneous cervical spine immobilisation: a comparison between four videolaryngoscopes and the Macintosh laryngoscope—a manikin study

被引:0
作者
Dawid Aleksandrowicz
Tomasz Gaszyński
机构
[1] Guy’s and St. Thomas’ NHS Foundation Trust,Anaesthetic Department
[2] St. Thomas’ Hospital,Department of Anaesthesiology and Intensive Therapy
[3] Medical University of Łódź,undefined
来源
Journal of Clinical Monitoring and Computing | 2018年 / 32卷
关键词
Intubation; Manikin study; Cervical spine immobilisation; Videolaryngoscope; Macintosh laryngoscope;
D O I
暂无
中图分类号
学科分类号
摘要
Excessive pressures exerted on the tongue during intubation may be associated with serious complications and may make intubation more difficult. The aim of this study was to evaluate five different intubating devices in the hands of experienced anaesthetists during simulated conditions of reduced cervical spine mobility. Forty senior anaesthetists participated in the study (female = 18, male = 22). The mean pressure exerted on the tongue during intubation was recorded with a standard manometer. The overall intubation success rate as well as the difference in exerted pressures between female and male anaesthetists were also assessed. The five studied devices were used by each participant and they were randomly chosen. Each anaesthetists participating in the study had over 15 years of clinical anaesthetic practice. The mean pressure exerted on the tongue during intubation was significantly lower when the videolaryngoscopes (VLs) were used (p < 0.0001 for each of the studied VL). There were failed intubation attempts with all of the studied devices, the highest failure rate was in the Airtraq® group, 10 in 40 (25%). Female anaesthetists exerted lower pressures during intubation with all studied devices (except the Airtraq®). However, the difference was only significant for the Macintosh laryngoscope (p = 0.0083). The blades of VLs exerted lower pressures on the tongue during intubation than the Macintosh laryngoscope blade. Their use may be associated with less complications. Furthermore, male anaesthetists exerted higher pressures on the soft tissues although this was neither statistically nor clinically significant. There was higher failed intubation rate in the male anaesthetist group.
引用
收藏
页码:907 / 913
页数:6
相关论文
共 93 条
[1]  
Wang HE(2006)Out-of-hospital endotracheal intubation: where are we? Ann Emerg Med 47 532-541
[2]  
Yealy DM(2009)Laryngoscopy force, visualization, and intubation failure in acute trauma: should we modify the practice of manual in-line stabilization? Anesthesiology 110 6-7
[3]  
Manoach S(2009)Manual in-line stabilization increases pressures applied by the laryngoscope blade during direct laryngoscopy and orotracheal intubation Anesthesiology 110 24-31
[4]  
Paladino L(2007)Complications of emergency tracheal intubation: immediate airway-related consequences: Part I J Intensive Care Med 22 157-165
[5]  
Santoni BG(2007)Complications of emergency tracheal intubation: immediate airway-related consequences: Part II J Intensive Care Med 22 208-215
[6]  
Hindman BJ(2007)Manual in-line stabilization for acute airway management of suspected cervical spine injury: historical review and current questions Ann Emerg Med 50 236-245
[7]  
Puttlitz CM(2009)Randomized controlled trial of the Pentax AWS®, GlideScope® and Macintosh laryngoscopes in predicted difficult intubation Br J Anaesth 103 761-768
[8]  
Weeks JB(2015)Endotracheal intubation using the Airtraq optical laryngoscope when the glottis is off-center of the viewfinder: are the options of optimization exhausted? Rev Bras Anestesiol 65 534-536
[9]  
Johnson N(2005)Complications of endotracheal intubation and other airway management procedures Indian J Anaesth 49 308-318
[10]  
Maktabi MA(2016)Comparison of the C-Mac video laryngoscope with the McGrath Series 5 video laryngoscope concerning an extremely difficult airway Anaesthesiol Intensive Ther 48 55-57