Development of a Glassy Carbon Electrode Modified with Graphene/Au Nanoparticles for Determination of Acetaminophen in Pharmaceutical Preparation

被引:0
作者
Yingliang Wei
Anting Wang
Yuanyuan Liu
机构
[1] Luoyang Institute of Science and Technology,School of Environmental Engineering and Chemistry
来源
Russian Journal of Electrochemistry | 2018年 / 54卷
关键词
acetaminophen; grapheme; Au nano-particle; voltammetry;
D O I
暂无
中图分类号
学科分类号
摘要
A graphene/Au nanoparticles composite modified glassy carbon electrode (GR/AuNPs/GCE) was developed. Electrochemical behavior of acetaminophen (ACOP) at this modified electrode was studied by liner sweep voltammetry (LSV) in pH 6.0 phosphate buffer solution. The effect factors of the electrochemical response of ACOP were optimized by LSV. Under the optimum conditions, a linear calibration curve of the oxidation peak current of ACOP and concentration was obtained in the range of 1.0 × 10–6 to ~2.2×10–4 M. The peak current increases linearly with the scan rate, indicating that the reaction of ACOP at the modified electrode is adsorption-controlled process. This new proposed method has been successfully employed to determine acetaminophen in pharmaceutical preparation.
引用
收藏
页码:1141 / 1147
页数:6
相关论文
共 103 条
  • [1] Bessems J.G.M.(2001)Paracetamol (acetaminophen)-induced toxicity: molecular and biochemical mechanisms, analogues and protective approaches Crit. Rev. Toxicol. 31 55-undefined
  • [2] Vermeulen N.P.E.(2008)Acetaminopheninduced liver damage in mice: effects of some medicinal plants on the oxidative defense system Exp. Toxicol. Pathol. 59 319-undefined
  • [3] Olaleye M.T.(1998)Differential chemoprotection against acetaminophen-induced hepatotoxicity by latentiated l-cysteines Chem. Res. Toxicol. 11 1274-undefined
  • [4] Rocha B.T.(2000)Fast determination of paracetamol by using a very simple photometric flow-through sensing device J. Pharm. Biomed. Anal. 22 59-undefined
  • [5] Roberts J.C.(2009)Two-dimensional liquid chromatography-ion trap mass spectrometry for the simultaneous determination of ketorolac enantiomers and paracetamol in human plasma: application to a pharmacokinetic study J. Chromatogr. A 1216 3851-undefined
  • [6] Phaneuf H.L.(2015)Simultaneous determination of acetaminophen and dihydrocodeine in human plasma by UPLC–MS/MS: its pharmacokinetic application J. Chromatogr. B 992 91-undefined
  • [7] Szakacs J.G.(1998)Determination of acetaminophen by flow injection with on-line chemical derivatization: investigations using visible and FT-IR spectrophotometry Anal. Chim. Acta 364 107-undefined
  • [8] Richard T.Z.(2012)An electrochemical approach to simultaneous determination of acetaminophen and floxacin Bull. Environ. Contam. Toxicol. 89 1284-undefined
  • [9] John G.L.(2013)Electrocatalytical oxidation and sensitive determination of acetaminophen on glassy carbon electrode modified with graphene-chitosan composite Mater. Sci. Eng. C 33 1514-undefined
  • [10] Michael R.F.(2015)Enhanced-oxidation and highly–sensitive detection of acetaminophen, guanine and adenine using NMPexfoliated graphene nanosheets-modified electrode Electrochim. Acta 166 285-undefined