Determination of dissolved iron(III) in estuarine and coastal waters by adsorptive stripping chronopotentiometry (SCP)

被引:0
|
作者
Ricardo D. Riso
Matthieu Waeles
Benoît Pernet-Coudrier
Pierre Le Corre
机构
[1] Université de Bretagne Occidentale (IUEM),Laboratoire de Chimie Marine
[2] UMR CNRS 7144 Roscoff,undefined
来源
关键词
Dissolved iron; Stripping chronopotentiometry; Estuarine waters; Coastal waters;
D O I
暂无
中图分类号
学科分类号
摘要
An adsorptive stripping chronopotentiometric (SCP) method has been developed for quantification of dissolved iron in estuarine and coastal waters. After UV-digestion of filtered samples the Fe(III) ions in non-deoxygenated samples were complexed with solochrom violet RS (SVRS). The complexes were then accumulated by adsorption on the surface of a mercury-film electrode. The stripping step was performed by applying a constant current of −17 μA. Sensitivity and detection limit were 15 ms nmol−1 L (270 ms μg−1 L) and 1.5 nmol L−1 (84 ng L−1), respectively, for 60-s electrolysis time. Compared with the only other chronopotentiometric method available for measurement of iron in natural waters, our procedure is fifty times more sensitive in a quarter of the electrolysis time. It therefore enables detection of the concentrations currently found in estuarine and coastal waters. The method was successfully used to study the behaviour and seasonal variations of dissolved iron in the Penzé estuary, NW France.
引用
收藏
页码:76 / 82
页数:6
相关论文
共 50 条
  • [21] Dissolved oxygen levels in estuarine and coastal waters around Ireland
    O'Boyle, Shane
    McDermott, Georgina
    Wilkes, Robert
    MARINE POLLUTION BULLETIN, 2009, 58 (11) : 1657 - 1663
  • [22] Determination of cobalt and iron in estuarine and coastal waters using flow injection with chemiluminescence detection
    Cannizzaro, V
    Bowie, AR
    Sax, A
    Achterberg, EP
    Worsfold, PJ
    ANALYST, 2000, 125 (01) : 51 - 57
  • [23] THE DETERMINATION OF MOLYBDENUM IN ESTUARINE WATERS USING CATHODIC STRIPPING VOLTAMMETRY
    KHAN, SH
    VAN DEN BERG, CMG
    MARINE CHEMISTRY, 1989, 27 (1-2) : 31 - 42
  • [24] Determination of Ni (II) in beverages without any sample pretreatment by adsorptive stripping chronopotentiometry (AdSCP)
    Dugo, G
    La Pera, L
    Lo Turco, V
    Di Bella, G
    Salvo, F
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2004, 52 (07) : 1829 - 1834
  • [25] Determination of the Natural Dissolved Concentration of Zirconium in Seawater by Adsorptive Stripping Voltammetry
    Schneider, Alexandre B.
    Nascimento, Paulo C.
    Bohrer, Denise
    de Carvalho, Leandro M.
    Guarda, Ananda
    Dias, Daiane
    Koschinsky, Andrea
    ELECTROANALYSIS, 2013, 25 (07) : 1628 - 1634
  • [26] Determination of dissolved monomethylmercury in saline, estuarine and fresh waters of Croatia
    Kwokal, Z
    Branica, M
    CROATICA CHEMICA ACTA, 2000, 73 (01) : 97 - 109
  • [27] A tin-bismuth alloy electrode for the cathodic stripping voltammetric determination of iron in coastal waters
    Lin, Mingyue
    Pan, Dawei
    Hu, Xueping
    Li, Fei
    Han, Haitao
    ANALYTICAL METHODS, 2015, 7 (12) : 5169 - 5174
  • [28] Adsorptive stripping voltammetric determination of aluminium using Arsenazo III
    Komersová, A
    Bartos, M
    Kalcher, K
    Vytras, K
    COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 2001, 66 (03) : 456 - 464
  • [29] Determination of chromium in iron and steel by adsorptive stripping voltammetry with diphenylcarbazide
    Tanaka, T
    Gozu, S
    Ishiyama, T
    Sato, M
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2000, 86 (03): : 166 - 170
  • [30] AC adsorptive stripping chronopotentiometric determination of dissolved aluminum in drinking waters and beverages using SVRS under alkaline conditions.
    Bi, SP
    Gan, N
    Zou, GW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 220 : U29 - U29