Bone remodelling in the pores and around load bearing transchondral isoelastic porous-coated glassy carbon implants: Experimental study in rabbits

被引:0
|
作者
T. Tarvainen
I. Paronen
T. Tunturi
J. Rautavuori
P. Tormala
H. Patiala
P. Rokkanen
机构
[1] Tampere City Hospital,Department of Surgery
[2] Tampere University Hospital,Department of Surgery
[3] Tampere University of Technology,Institute of Biomaterials
[4] Helsinki University,Department of Orthopaedics and Traumatology
关键词
Cortical Bone; Glassy Carbon; Bone Remodelling; Cancellous Bone; Articular Surface;
D O I
暂无
中图分类号
学科分类号
摘要
Cylinders of porous-coated glassy carbon were implanted into drill holes made through the articular surface of the medial condyle of both tibiae of ten rabbits for six and 12 weeks. Bone ingrowth and remodelling was examined by radiographic, histologic, oxytetracycline-fluorescence and microradiographic methods. Bone ingrowth into pores and load bearing implants was seen by all examination methods. Bone ingrowth occurred earlier when the pores were facing cancellous bone than cortical bone. Appositional bone formation occurred on the trabeculae a few millimetres from the interface during the early phase of remodelling at six weeks. At 12 weeks resorptive remodelling had occurred both in the surroundings and in those pores that face cancellous bone, whereas the amount of bone still increased in the pores facing cortical bone. In its porous-coated form glassy carbon functions well as a frame for ingrowing bone and it shows good osteoconductivity. Its mechanical properties are suitable for functioning as a structural bone substitute in places where the loads are mainly compressive. The difference between findings at six and 12 weeks indicated physiologic stress distribution and the adverse effects of stiff materials on bone remodelling were avoided by using this isoelastic material.
引用
收藏
页码:509 / 515
页数:6
相关论文
共 29 条
  • [21] PREDICTABLE CRESTAL BONE REMODELING AROUND 2 POROUS-COATED TITANIUM-ALLOY DENTAL IMPLANT DESIGNS - A RADIOGRAPHIC STUDY IN DOGS
    ALSAYYED, A
    DEPORTER, DA
    PILLIAR, RM
    WATSON, PA
    PHAROAH, M
    BERHANE, K
    CARTER, S
    CLINICAL ORAL IMPLANTS RESEARCH, 1994, 5 (03) : 131 - 141
  • [22] Effect of Surface Modifications on Early Bone Healing Around Plateau Root Form Implants: An Experimental Study in Rabbits
    Suzuki, Marcelo
    Calasans-Maia, Monica D.
    Mann, Charles
    Granato, Rodrigo
    Gil, Jose N.
    Granjeiro, Jose M.
    Coelho, Paulo G.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 68 (07) : 1631 - 1638
  • [23] Effects of decortication in the treatment of bone defect around particulate dentin-coated implants: an experimental pilot study
    Seol, Ka-Young
    Kim, Su-Gwan
    Kim, Hak-Kyun
    Moon, Seong-Yong
    Kim, Byung-Ock
    Ahn, Jong-Mo
    Jang, Hyun-Sun
    Kim, Hee-Jung
    Min, Jeong-Bum
    Lee, Byoung-Jin
    Lim, Sung-Chul
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (04): : 529 - 536
  • [24] DUAL-ENERGY X-RAY ABSORPTIOMETRY MEASUREMENT OF BONE-MINERAL DENSITY AROUND POROUS-COATED CEMENTLESS FEMORAL IMPLANTS - METHODS AND PRELIMINARY-RESULTS
    KILGUS, DJ
    SHIMAOKA, EE
    TIPTON, JS
    EBERLE, RW
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (02): : 279 - 287
  • [25] Bone reaction adjacent to microplasma-sprayed calcium phosphate-coated oral implants subjected to an occlusal load, an experimental study in the dog
    Junker, R.
    Manders, P. J. D.
    Wolke, J.
    Borisov, Y.
    Braceras, I.
    Jansen, John A.
    CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (02) : 135 - 142
  • [26] RETRACTION: Bone remodelling after regenerative procedures around implants placed in fresh extraction sockets: an experimental study in Beagle dogs (Retraction of Vol 22, Pg 1131, 2011)
    Barone, A.
    Ricci, M.
    Calvo-Guirado, J. L.
    Covani, U.
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (05) : 539 - 539
  • [27] Bone ingrowth into porous bioactive titanium implant for load-bearing use: Experimental study using a novel canine anterior interbody fusion model
    Takemoto, M.
    Fujibayashi, S.
    Neo, M.
    So, K.
    Akiyama, N.
    Matsushita, T.
    Kokubo, T.
    Nakamura, T.
    BIOCERAMICS, VOL 19, PTS 1 AND 2, 2007, 330-332 : 987 - +
  • [28] Bone reaction adjacent to microplasma-sprayed CaP-coated oral implants subjected to occlusal load, an experimental study in the dog. Part I: short-term results
    Junker, R.
    Manders, P. J. D.
    Wolke, J.
    Borisov, Y.
    Jansen, J. A.
    CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (11) : 1251 - 1263
  • [29] RETRACTED: Bone remodelling after regenerative procedures around implants placed in fresh extraction sockets: an experimental study in Beagle dogs (Retracted article. See vol. 29, pg. 539, 2018)
    Barone, A.
    Ricci, M.
    Calvo-Guirado, J. L.
    Covani, U.
    CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (10) : 1131 - 1137