Stem diameter and rotational stability in revision total hip arthroplasty: A biomechanical analysis

被引:25
作者
Michael Meneghini R. [1 ]
Hallab N.J. [2 ]
Berger R.A. [2 ]
Jacobs J.J. [2 ]
Paprosky W.G. [2 ]
Rosenberg A.G. [2 ]
机构
[1] Joint Replacement Surgeons of Indiana Research Foundation, St. Vincent Center for Joint Replacement, Indianapolis, IN
[2] Department of Orthopaedic Surgery, Rush Medical College, Rush University Medical Center, Chicago, IL
关键词
Femoral Component; Stem Diameter; Rotational Stability; Stem Size; Torque Resistance;
D O I
10.1186/1749-799X-1-5
中图分类号
学科分类号
摘要
Background: Proximal femoral bone loss during revision hip arthroplasty often requires bypassing the deficient metaphyseal bone to obtain distal fixation. The purpose of this study was to determine the effect of stem diameter and length of diaphyseal contact in achieving rotational stability in revision total hip arthroplasty. Methods: Twenty-four cadaveric femoral specimens were implanted with a fully porous-coated stem. Two different diameters were tested and the stems were implanted at multiple contact lengths without proximal bone support. Each specimen underwent torsional testing to failure and rotational micromotion was measured at the implant-bone interface. Results: The larger stem diameter demonstrated a greater torsional stability for a given length of cortical contact (p ≤ 0.05). Decreasing length of diaphyseal contact length was associated with less torsional stability. Torsional resistance was inconsistent at 2 cm of depth. Conclusion: Larger stem diameters frequently used in revisions may be associated with less diaphyseal contact length to achieve equivalent rotational stability compared to smaller diameter stems. Furthermore, a minimum of 3 cm or 4 cm of diaphyseal contact with a porous-coated stem should be achieved in proximal femoral bone deficiency and will likely be dependent on the stem diameter utilized at the time of surgery.
引用
收藏
相关论文
共 27 条
  • [1] Paprosky W.G., Greidanus N.V., Antoniou J., Minimum 10-year-results of extensively porous-coated stems in revision hip arthroplasty, Clin Orthop, pp. 230-242, (1999)
  • [2] Aribindi R., Barba M., Solomon M.I., Arp P., Paprosky W., Bypass fixation, Orthop Clin North Am, 29, 2, pp. 319-329, (1998)
  • [3] Engh C.A.J., Ellis T.J., Koralewicz L.M., McAuley J.P., Engh C.A.S., Extensively porous-coated femoral revision for severe femoral bone loss: Minimum 10-year follow-up, J Arthroplasty, 17, 8, pp. 955-960, (2002)
  • [4] Sugiyama H., Whiteside L.A., Kaiser A.D., Examination of rotational fixation of the femoral component in total hip arthroplasty. A mechanical study of micromovement and acoustic emission, Clin Orthop, pp. 122-128, (1989)
  • [5] Larson J.E., Chao E.Y., Fitzgerald R.H., Bypassing femoral cortical defects with cemented intramedullary stems, J Orthop Res, 9, 3, pp. 414-421, (1991)
  • [6] Wroblewski B.M., The mechanism of fracture of the femoral prosthesis in total hip replacement, Int Orthop, 3, 2, pp. 137-139, (1979)
  • [7] Burke D.W., O'Connor D.O., Zalenski E.B., Jasty M., Harris W.H., Micromotion of cemented and uncemented femoral components, J Bone Joint Surg Br, 73, 1, pp. 33-37, (1991)
  • [8] Mjoberg B., Hansson L.I., Selvik G., Instability of total hip prostheses at rotational stress. A roentgen stereophotogrammetric study, Acta Orthop Scand, 55, 5, pp. 504-506, (1984)
  • [9] Engh C.A., O'Connor D., Jasty M., McGovern T.F., Bobyn J.D., Harris W.H., Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses, Clin Orthop, pp. 13-29, (1992)
  • [10] Otani T., Whiteside L.A., White S.E., McCarthy D.S., Reaming technique of the femoral diaphysis in cementless total hip arthroplasty, Clin Orthop, pp. 210-221, (1995)