FRP confinement of wall-like reinforced concrete columns

被引:0
作者
T. C. Triantafillou
E. Choutopoulou
E. Fotaki
M. Skorda
M. Stathopoulou
K. Karlos
机构
[1] University of Patras,Department of Civil Engineering
来源
Materials and Structures | 2016年 / 49卷
关键词
Concrete; Confinement; Fiber-reinforced polymers; Shape enlargement; Spike anchors; Wall-like columns;
D O I
暂无
中图分类号
学科分类号
摘要
The paper investigates FRP confinement of wall-like reinforced concrete columns in a systematic way, by examining a number of parameters not addressed before: the effectiveness of different types of anchors, the role of different cross section aspect ratios (3 and 4), the number of layers, local strengthening at the corners and the reduction of aspect ratio by cross section enlargement. These parameters are combined in an analytical model for the ultimate load in concentrically loaded columns, which is found in good agreement with test results. It is concluded that: properly dimensioned (heavy) anchors nearly double the confining effectiveness of FRP; the use of additional FRP layers near the edges of the cross section increases the confining effectiveness of the jacket by approximately 50 %; and shape enlargement of the cross section with mortar is practically as effective as the use of heavy anchors.
引用
收藏
页码:651 / 664
页数:13
相关论文
共 54 条
  • [1] Ceroni F(2010)Evaluation of bond strength in concrete elements externally reinforced with CFRP sheets and anchoring devices J Compos Constr 14 521-530
  • [2] Pecce M(2006)Flexural fatigue behavior of reinforced concrete beams strengthened with FRP fabric and precured laminate systems J Compos Constr 10 433-442
  • [3] Ekenel M(2008)Performance of two anchor systems of externally bonded fiber-reinforced polymer laminates ACI Mater J 105 72-80
  • [4] Rizzo A(2006)Stress-strain model for fiber-reinforced polymer jacketed concrete columns ACI Struct J 103 672-682
  • [5] Myers JJ(2008)FRP retrofit of low and medium strength circular and rectangular reinforced concrete columns J Mater Civ Eng 20 169-188
  • [6] Nanni A(2005)Experimental investigation of non-conventional confinement for concrete using FRP J Comp Constr 9 480-487
  • [7] Eshwar N(2010)Pullout strength models for FRP anchors in uncracked concrete J Compos Constr 14 406-414
  • [8] Nanni A(2011)Use of carbon fiber-reinforced polymer anchors to repair and strengthen lap splices of reinforced concrete columns ACI Struct J 108 630-640
  • [9] Ibell TJ(2013)Use of anchors in shear strengthening of reinforced concrete T-beams with FRP J Compos Constr 17 101-107
  • [10] Harajli M(2003)Design-oriented stress-strain model for FRP-confined concrete in rectangular columns J Reinf Plast Compos 22 1149-1186