Evaluation of various image reconstruction parameters in lower extremity stents using multidetector-row CT angiography: initial findings

被引:0
作者
Martin Heuschmid
Benjamin Wiesinger
Gunnar Tepe
Oliver Luz
Andreas F. Kopp
Claus D. Claussen
Stephan H. Duda
机构
[1] Eberhard-Karls-University,Department of Diagnostic Radiology, University Hospital Tuebingen
[2] Jewish Hospital Berlin,Department of Radiology
来源
European Radiology | 2007年 / 17卷
关键词
Multidetector-row CT; CT angiography; Digital subtraction angiography; Lower extremity; Stent;
D O I
暂无
中图分类号
学科分类号
摘要
Image quality, visible lumen and patency of lower limb stents was assessed by multidetector-row computed tomography (MDCT) angiography using various reconstruction parameters and the results compared with conventional angiography. Fourteen patients (25 stents) were evaluated. From MDCT datasets, axial and coronal oblique reformations were reconstructed using differing reconstruction parameters (slice thickness, kernel, views). Artifacts and image quality were assessed using a five-degree scale (1=excellent, 5=poor). Visible stent diameter was measured. Stenosis severity was compared with calibrated catheter angiography. The image quality of medium and sharp image kernels were good/fair (1.9–2.4), while smooth kernel provided only acceptable/poor image quality (3.9–4.4). Coronal oblique images were rated superior to assess in-stent lumen rather than axial. Using medium and sharp kernels, the visible stent lumen was significantly greater than using smooth kernel (P<0.001). thirteen out of fourteen patients (24/25 stents) were correctly classified as patent. In one patient, in-stent stenosis (≥50%) was falsely diagnosed using CT angiography (CTA) with smooth kernel and was, therefore, rated as false positive. Coronal oblique views, as well as medium and sharp kernels, have shown the best results regarding image quality to assess stent patency in the lower limb. Therefore, MDCT could be a valuable non-invasive modality for stent imaging in the peripheral vasculature.
引用
收藏
页码:265 / 271
页数:6
相关论文
共 222 条
[1]  
Amento EP(1991)Cytokines and growth factors positively and negatively regulate interstitial collagen gene expression in human vascular smooth muscle cells Arterioscler Thromb 11 1223-1230
[2]  
Ehsani N(1992)Coronary intimal proliferation after balloon injury and stenting in swine: an animal model of restenosis J Am Coll Cardiol 20 467-474
[3]  
Palmer H(2002)Thrombogenicity of various endovascular stent types: an in-vitro evaluation J Vasc Interv Radiol 13 1029-1035
[4]  
Libby P(2004)Sonographic follow-up after visceral artery stenting J Ultrasound 23 1057-1064
[5]  
Karas SP(1999)The use of duplex ultrasound arterial mapping as an alternative to conventional arteriography for primary and secondary infrapopliteal bypasses Am J Surg 178 162-165
[6]  
Gravanis MB(2004)Whole-body 3D MR angiography of patients with peripheral arterial occlusive disease AJR Am J Roentgenol 182 1427-1434
[7]  
Santoian EC(2004)Assessment of vasculature using combined MRI and MR angiography AJR Am J Roentgenol 182 861-866
[8]  
Robinson KA(1999)Iliofemoral arterial occlusive disease: contrast-enhanced MR angiography for preinterventional evaluation and follow-up after stent placement Radiology 212 371-377
[9]  
Anderberg KA(1999)Aotoiliac and lower extremity arteries: comparison of three-dimensional dynamic contrast-enhanced subtraction MR angiography and conventional angiography Radiology 210 683-686
[10]  
King SB(2002)Peripheral vascular occlusive disease: evaluation with contrast-enhanced moving-bed MR angiography versus digital subtraction angiography in 106 patients AJR Am J Roentgenol 179 1013-1021