Aqueous Humor Circulation in the Era of Minimally Invasive Surgery for Glaucoma

被引:0
作者
Minas T. Coroneo
Gabriel Graterol-Nisi
Eric Maver
R. Mark Gillies
机构
[1] Ophthalmic Surgeons,Department of Ophthalmology
[2] Prince of Wales Hospital/University of New South Wales,undefined
[3] Medical Device Research Australia Pty Ltd,undefined
来源
Annals of Biomedical Engineering | 2024年 / 52卷
关键词
Glaucoma; Aqueous humor; Microstent; Aqueous circulation; Corneal endothelium; Intraocular pressure (IOP);
D O I
暂无
中图分类号
学科分类号
摘要
Glaucoma surgery with implantation of aqueous humor draining microstents may compromise long-term corneal health by disrupting aqueous humor circulation. The effect of stent numbers on this circulation was interrogated to determine the number of stents associated with minimal circulation disruption. An in vitro anterior eye model perfusion system was constructed with multiple exit ports. A 3-D model of the anterior eye was imported into ABAQUS CFD, analyzes were carried out for unsteady laminar flow and solved using Navier-Stokes equations. DT Vision Foundry was used to analyze velocity contour plot images. The field variable results output for the CFD model were fluid wall shear, fluid pressure and fluid velocity. In vitro, “aqueous” fluid flow is high through a single stent and “aqueous” stagnation is greatest in the quadrants 180° away. Increasing stent port numbers, results in an exponential decrease in the stagnant flow locations. High wall shear stress was seen in the single stent model and is markedly reduced after a second and subsequent stents are introduced. We identify two factors potentially contributing to corneal compromise post glaucoma drainage surgery: aqueous humor stagnation, remote to the stent site and higher exit flows imparting increased stent exit shear stress (particularly with a single stent). With 4 stents, there is minimal disruption of anterior chamber circulation (mimicking physiological conditions). Furthermore we propose that aqueous humor circulation disruption via the usual single-exit port approach disrupts aqueous humor circulation with long-term consequences for corneal health.
引用
收藏
页码:898 / 907
页数:9
相关论文
共 164 条
  • [21] Vieversyte Z(2016)Effect of obstructive sleep apnea syndrome on corneal thickness Int Ophthalmol. 36 202-1972
  • [22] Jaruseviciene R(1934)Glaucoma: a historical essay Bull Inst Hist Med. 2 1965-168
  • [23] Galgauskas S(2021)Aqueous humour outflow imaging: seeing is believing Eye (Lond). 35 166-524
  • [24] Asoklis R(2007)Predictors of long-term progression in the early manifest glaucoma trial Ophthalmology. 114 511-145
  • [25] Zablockis R(2006)Inferior corneal decompensation following laser peripheral iridotomy in the superior iris Am J Ophthalmol. 142 139-425
  • [26] Brubaker RF(1974)Functional and electron microscopic changes in the trabecular meshwork remaining after trabeculectomy in cynomolgus monkeys Invest Ophthalmol. 13 415-2954
  • [27] Cha EDK(1998)The Von Sallmann Lecture 1996: an ophthalmological explanation of REM sleep Exp Eye Res. 66 2945-885
  • [28] Xu J(2016)REM sleep homeostasis in the absence of REM sleep: effects of antidepressants Neuropharmacology. 108 881-19708
  • [29] Gong L(2010)A modular culture system for the generation of multiple specialized tissues Biomaterials. 31 19702-1600
  • [30] Gong H(1976)Control of bleb fibrosis after glaucoma surgery by anti-inflammatory agents S Afr Med J. 50 1589-757