Aqueous Humor Circulation in the Era of Minimally Invasive Surgery for Glaucoma

被引:0
作者
Minas T. Coroneo
Gabriel Graterol-Nisi
Eric Maver
R. Mark Gillies
机构
[1] Ophthalmic Surgeons,Department of Ophthalmology
[2] Prince of Wales Hospital/University of New South Wales,undefined
[3] Medical Device Research Australia Pty Ltd,undefined
来源
Annals of Biomedical Engineering | 2024年 / 52卷
关键词
Glaucoma; Aqueous humor; Microstent; Aqueous circulation; Corneal endothelium; Intraocular pressure (IOP);
D O I
暂无
中图分类号
学科分类号
摘要
Glaucoma surgery with implantation of aqueous humor draining microstents may compromise long-term corneal health by disrupting aqueous humor circulation. The effect of stent numbers on this circulation was interrogated to determine the number of stents associated with minimal circulation disruption. An in vitro anterior eye model perfusion system was constructed with multiple exit ports. A 3-D model of the anterior eye was imported into ABAQUS CFD, analyzes were carried out for unsteady laminar flow and solved using Navier-Stokes equations. DT Vision Foundry was used to analyze velocity contour plot images. The field variable results output for the CFD model were fluid wall shear, fluid pressure and fluid velocity. In vitro, “aqueous” fluid flow is high through a single stent and “aqueous” stagnation is greatest in the quadrants 180° away. Increasing stent port numbers, results in an exponential decrease in the stagnant flow locations. High wall shear stress was seen in the single stent model and is markedly reduced after a second and subsequent stents are introduced. We identify two factors potentially contributing to corneal compromise post glaucoma drainage surgery: aqueous humor stagnation, remote to the stent site and higher exit flows imparting increased stent exit shear stress (particularly with a single stent). With 4 stents, there is minimal disruption of anterior chamber circulation (mimicking physiological conditions). Furthermore we propose that aqueous humor circulation disruption via the usual single-exit port approach disrupts aqueous humor circulation with long-term consequences for corneal health.
引用
收藏
页码:898 / 907
页数:9
相关论文
共 164 条
  • [1] Abouali O(2012)Investigation of saccadic eye movement effects on the fluid dynamic in the anterior chamber J Biomech Eng. 134 202-207
  • [2] Modareszadeh A(2009)Outcome and prognosis of pediatric patients with delayed diagnosis of open-globe injuries J Pediatr Ophthalmol Strabismus. 46 191-200
  • [3] Ghaffarieh A(2006)Retinal ganglion cell line apoptosis induced by hydrostatic pressure Brain Res. 1086 495-503
  • [4] Tu J(2000)Pressure related apoptosis in neuronal cell lines J Neurosci Res. 60 126-130
  • [5] Acuna OM(2013)Glaucoma drainage implant surgery–an evidence-based update with relevance to sub-Saharan Africa Middle East Afr J Ophthalmol. 20 125-133
  • [6] Yen KG(2008)Maintaining transparency: a review of the developmental physiology and pathophysiology of two avascular tissues Semin Cell Dev Biol. 19 1576-1581
  • [7] Agar A(2019)Effect of obstructive sleep apnea on corneal morphological characteristics Cornea. 38 3145-3166
  • [8] Li S(1991)Flow of aqueous humor in humans [The Friedenwald Lecture] Invest Ophthalmol Vis Sci 32 354-360
  • [9] Agarwal N(2016)Variations in active outflow along the trabecular outflow pathway Exp Eye Res. 146 77-739
  • [10] Coroneo MT(2015)An in vitro test bench reproducing coronary blood flow signals Biomed Eng Online. 14 734-113