Durability of treatment effects of the sleep position trainer versus oral appliance therapy in positional OSA: 12-month follow-up of a randomized controlled trial (vol 22, pg 441, 2017)

被引:3
作者
de Ruiter, Maurits H. T. [1 ]
Benoist, Linda B. L. [2 ,3 ,4 ]
de Vries, Nico [2 ,5 ,6 ,7 ]
de Lange, Jan [1 ,5 ]
机构
[1] Acad Med Ctr, Dept Oral & Maxillofacial Surg, Amsterdam, Netherlands
[2] OLVG West, Dept Otorhinolaryngol Head & Neck Surg, Jan Tooropstr 164, Amsterdam, Netherlands
[3] Erasmus Univ, Med Ctr, Dept Otorhinolaryngol, Rotterdam, Netherlands
[4] Erasmus Univ, Med Ctr, Dept Head & Neck Surg, Rotterdam, Netherlands
[5] Acad Ctr Dent Amsterdam ACTA, Dept Oral Kinesiol, Amsterdam, Netherlands
[6] Antwerp Univ Hosp, Dept Otolaryngol, Antwerp, Belgium
[7] Antwerp Univ Hosp, Dept Head & Neck Surg, Antwerp, Belgium
关键词
Obstructive sleep apnea; Oral appliance therapy; Positional therapy; Randomized controlled trial; Sleep position;
D O I
10.1007/s11325-017-1580-8
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose The Sleep Position Trainer (SPT) is a new option for treating patients with positional obstructive sleep apnea (POSA). This study investigated long-term efficacy, adherence, and quality of life during use of the SPT device compared with oral appliance therapy (OAT) in patients with POSA. Methods This prospective, multicenter trial randomized patients with mild to moderate POSA (apnea-hypopnea index [AHI] 5-30/h) to SPT or OAT. Polysomnography was performed at baseline and after 3 and 12 months' follow-up. The primary endpoint was OSA severity; adherence, quality of life, and adverse events were also assessed. Results Ninety-nine patients were randomized and 58 completed the study (29 in each group). Median AHI in the SPT group decreased from 13.2/h at baseline to 7.1/h after 12 months (P < 0.001); corresponding values in the OAT group were 13.4/h and 5.0/h (P < 0.001), with no significant between-group difference (P = 1.000). Improvements throughout the study were maintained at 12 months. Longterm median adherence was also similar in the two treatment groups; the proportion of patients who used their device for >= 4 h for 5 days in a week was 100% in the SPT group and 97.0% in the OAT group (P = 0.598). Conclusions The efficacy of SPT therapy was maintained over 12 months and was comparable to that of OAT in patients with mild to moderate POSA. Adherence was relatively high, and similar in the two groups.
引用
收藏
页码:451 / 451
页数:1
相关论文
共 1 条
[1]  
de Ruiter MHT, 2018, SLEEP BREATH, V22, P441, DOI 10.1007/s11325-017-1568-4