Papillary muscle rupture after myocardial infarction during left ventricular assist device support

被引:0
作者
Shingo Kunioka
Hiroto Kitahara
Hirotsugu Kanda
Tomohiro Takeda
Yuri Yoshida
Natsuya Ishikawa
Hiroyuki Kamiya
机构
[1] Asahikawa Medical University Hospital,Department of Cardiac Surgery
[2] Asahikawa Medical University Hospital,Department of Anesthesiology and Critical Care Medicine
[3] The University of Chicago,Section of Cardiac and Thoracic Surgery, Department of Surgery
来源
Journal of Artificial Organs | 2017年 / 20卷
关键词
Papillary muscle rupture; Mitral regurgitation; Left ventricular assist device;
D O I
暂无
中图分类号
学科分类号
摘要
We report a rare case of papillary muscle rupture due to myocardial infarction during left ventricular assist device support. A 69-year-old woman with cardiogenic shock due to acute myocardial infarction requiring venoarterial extracorporeal membrane oxygenation support was transferred for further surgical intervention. Six days after the event, extracorporeal membrane oxygenation was decannulated, and an extracorporeal left ventricular assist device was implanted. On postoperative day 11, she suffered from sudden onset hypoxia due to pulmonary edema. Transesophageal echocardiography showed new onset severe mitral regurgitation. No further surgical intervention was performed according to the family’s wishes, and she passed away on the 22nd postoperative day. Autopsy findings revealed papillary muscle rupture. Although the left ventricle is unloaded by the left ventricular assist device, papillary muscle rupture should be recognized as a possible complication after myocardial infarction.
引用
收藏
页码:263 / 265
页数:2
相关论文
共 89 条
[1]  
Acharya D(2016)Ventricular assist device in acute myocardial infarction J Am Coll Cardiol 67 1871-1880
[2]  
Loyaga-Rendon RY(2014)Evolving strategies in the treatment of acute myocardial infarction-induced cardiogenic shock Ann Cardiothorac Surg 3 606-611
[3]  
Pamboukian SV(2007)An unusual complication of support with a continuous-flow cardiac assist device N Engl J Med 357 936-937
[4]  
Tallaj JA(2010)Mechanical complications after percutaneous coronary intervention in ST-elevation myocardial infarction (from APEX-AMI) Am J Cardiol 105 59-63
[5]  
Holman WL(2011)Effects of continuous-flow versus pulsatile-flow left ventricular assist devices on myocardial unloading and remodeling Circ Heart Fail 4 546-553
[6]  
Cantor RS(2011)Is bridge to recovery more likely with pulsatile left ventricular assist devices than with nonplusatile-flow sysgems? Ann Thorac Surg 91 1335-1340
[7]  
Naftel DC(2015)Advantage of pulsatility in left ventricular reverse remodeling and aortic insufficiency prevention during left ventricular assist device treatment Circ J 79 1994-1999
[8]  
Kirklin JK(2015)Uncorrected pre-operative mitral valve regurgitation is not associated with adverse outcomes after continuous-flow left ventricular assist device implantation J Heart Lung Transplant 34 718-723
[9]  
Tchantchaleishvili V(2017)Surgically corrected mitral regurgitation during left ventricular assist device implantation is associated with low recurrence rate and improved midterm survival Ann Thorac Surg 103 725-733
[10]  
Schubmehl H(2013)Mitral valve repair at the time of continuous-flow left ventricular assist device implantation confers meaningful decrement in pulmonary vascular resistance ASAIO J 59 469-473