Multidetector computed tomography (MDCT) evaluation of myocardial viability: intraindividual comparison of monomeric vs. dimeric contrast media in a rabbit model

被引:0
作者
Andreas H. Mahnken
Gregor Jost
Philipp Bruners
Martin Sieber
Peter R. Seidensticker
Rolf W. Günther
Hubertus Pietsch
机构
[1] RWTH Aachen University,Department of Diagnostic Radiology
[2] RWTH Aachen University,Applied Medical Engineering, Helmholtz Institute
[3] Bayer-Schering Pharma AG,Department of Diagnostic Radiology
[4] University Hospital,undefined
[5] RWTH Aachen University,undefined
来源
European Radiology | 2009年 / 19卷
关键词
Computed tomography; MDCT; Contrast media; Heart; Myocardial infarction;
D O I
暂无
中图分类号
学科分类号
摘要
To evaluate the influence of different types of iodinated contrast media on the assessment of myocardial viability, acute myocardial infarction (MI) was surgically induced in six rabbits. Over a period of 45 min, contrast-enhanced cardiac MDCT (64 × 0.6 mm, 80 kV, 680mAseff.) was repeatedly performed using a contrast medium dose of 600 mg iodine/kg body weight. Animals received randomized iopromide 300 and iodixanol 320, respectively. Attenuation values of healthy and infarcted myocardium were measured. The size of MI was computed and compared with nitroblue tetrazolium (NBT)-stained specimen. The highest attenuation differences between infarcted and healthy myocardium occurred during the arterial phase with 140.0 ± 3.5 HU and 141.0 ± 2.2 HU for iopromide and iodixanol, respectively. For iodixanol the highest attenuation difference on delayed contrast-enhanced images was achieved 3 min post injection (73.5 HU). A slightly higher attenuation difference was observed for iopromide 6 min after contrast medium injection (82.2 HU), although not statistically significant (p = 0.6437). Mean infarct volume as measured by NBT staining was 33.5% ± 13.6%. There was an excellent agreement of infarct sizes among NBT-, iopromide- and iodixanol-enhanced MDCT with concordance-correlation coefficients ranging from ρ(c)  = 0.9928–0.9982. Iopromide and iodixanol both allow a reliable assessment of MI with delayed contrast-enhanced MDCT.
引用
收藏
页码:290 / 297
页数:7
相关论文
共 85 条
  • [1] Wu KC(2003)Noninvasive imaging of myocardial viability: current techniques and future developments Circ Res 93 1146-1158
  • [2] Lima JA(1999)Relationship of MRI delayed contrast enhancement to irreversible injury, infarct age, and contractile function Circulation 100 1992-2002
  • [3] Kim RJ(1996)Myocardial Gd-DTPA kinetics determine MRI contrast enhancement and reflect the extent and severity of myocardial injury after acute reperfused infarction Circulation 94 3318-3326
  • [4] Fieno DS(2003)Contrast-enhanced MRI and routine single photon emission computed tomography (SPECT) perfusion imaging for detection of subendocardial myocardial infarcts: an imaging study Lancet 361 374-379
  • [5] Parrish TB(2005)Late defect on delayed contrast-enhanced multi-detector row CT scans in the prediction of SPECT infarct size after reperfused acute myocardial infarction: initial experience Radiology 236 485-489
  • [6] Kim RJ(2005)Assessment of myocardial viability in reperfused acute myocardial infarction using 16-slice computed tomography in comparison to magnetic resonance imaging J Am Coll Cardiol 45 2042-2047
  • [7] Chen EL(2004)Usefulness of Multidetector-row CT in the evaluation of reperfused myocardial infarction in a rabbit model Korean J Radiol 5 19-24
  • [8] Lima JA(2007)Late-phase MSCT in the different stages of myocardial infarction: animal experiments Eur Radiol 17 2310-2317
  • [9] Judd RM(1980)Uptake of iodinated contrast material in ischemic myocardium as an indicator of loss of cellular membrane integrity Am Assoc Path 101 319-327
  • [10] Wagner A(2004)Performance evaluation of a 64-slice CT system with z-flying focal spot Rofo 176 1803-1810