Modernization of standard and rapid pressure-reducing and cooling units with injection of high pressure water

被引:0
|
作者
Ermolaev V.V. [1 ]
Andreev A.P. [1 ]
机构
[1] JSC Firma Soyuz-01, Moscow
来源
Power Technol. Eng. | 2008年 / 4卷 / 222-229期
关键词
Bushing with a tangential fluid feed; Injector regulator valves; Modernization; Multistep throttling; Pressure-reducing and cooling units; Rapid pressure-reducing and cooling units; Steam desuperheaters; Steam-and-water injector; Worm swirler;
D O I
10.1007/s10749-008-0039-2
中图分类号
学科分类号
摘要
Operating experience with different standard (ROU) and rapid (BROU) pressure-reducing and cooling units is examined. A scheme for updating standard ROU and BROU steam desuperheaters is proposed which avoids formation of stress concentrations and erosion washout of the parts by eliminating the rigid connection between the feeder element and the injector device: modernization of commercial steam inlet nozzles and injector regulator valves with multistep throttling of the working medium which ensures reliable, long duration operation with water feed from an electrical feed pump. For the modernized version it is proposed that the worm swirler be replaced by a bushing with a tangential fluid feed. Modernization can be done in the repair shops of operating power plants, as well as at the manufacturers' plants. © 2008 Springer Science+Business Media, Inc.
引用
收藏
页码:222 / 229
页数:7
相关论文
共 50 条