Accuracy of thoracic pedicle screw placement in scoliosis using the ideal pedicle entry point during the freehand technique

被引:0
作者
Hitesh Modi
Seung Woo Suh
Hae-Ryong Song
Jae-Hyuk Yang
机构
[1] Korea University Guro Hospital,Department of Orthopedics, Scoliosis Research Institute
[2] Korea University Guro Hospital,Department of Orthopedics, Rare Disease Institute
[3] Korea University Guro Hospital,Department Of Orthopaedics
来源
International Orthopaedics | 2009年 / 33卷
关键词
Pedicle Screw; Thoracic Spine; Safe Zone; Pelvic Obliquity; Neuromuscular Scoliosis;
D O I
暂无
中图分类号
学科分类号
摘要
Previously, we described the ideal pedicle entry point (IPEP) for the thoracic spine at the base of the superior facet at the junction of the lateral one third and medial two thirds with the freehand technique on cadavers. Here we measured the accuracy of thoracic pedicle screw placement (Chung et al. Int Orthop 2008) on post-operative computed tomography (CT) scans in 43 scoliosis patients who underwent operation with the freehand technique taking the same entry point. Of the 854 inserted screws, 268 (31.3%) were displaced; 88 (10.3%) and 180 (21.0%) screws were displaced medially and laterally, respectively. With regard to the safe zone, 795 screws were within the safe zone representing an accuracy rate of 93%; 448 and 406 thoracic screws inserted in adolescent idiopathic and neuromuscular scoliosis showed an accuracy of 89.9 and 94%, respectively (p = 0.6475). The accuracy rate of screws inserted in the upper, middle and lower thoracic pedicles were 94.2, 91.6 and 93.7%, respectively (p = 0.2411). The results indicate that IPEP should be considered by surgeons during thoracic pedicle screw instrumentation.
引用
收藏
页码:469 / 475
页数:6
相关论文
共 95 条
[1]  
Belmont PJ(2001)In vivo accuracy of thoracic pedicle screws Spine 26 2340-2346
[2]  
Klemme WR(1959)A method of spinal fusion J Bone Joint Surg Br 41 248-259
[3]  
Dhawan A(1989)Spinal fusion augmented by luque-rod segmental instrumentation for neuromuscular scoliosis J Bone Joint Surg Am 71 32-44
[4]  
Polly DW(1998)Complications of pediatric thoracolumbar and lumbar pedicle screws Spine 23 1566-1571
[5]  
Boucher HH(1999)Pedicle instrumentation in the thoracic spine. A morphometric and cadaveric study for placement of screws Spine 24 654-658
[6]  
Broom MJ(1993)An anatomic, radiographic, and biomechanical assessment of extrapedicular screw fixation in the thoracic spine Spine 18 1689-1694
[7]  
Banta JV(1997)Anatomic relations of the thoracic pedicle to adjacent neural structures Spine 22 1553-1557
[8]  
Renshaw TS(1993)Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members Spine 18 2231-2239
[9]  
Brown CA(1997)Early complications of spinal pedicle screw Eur Spine J 6 324-326
[10]  
Lenke LG(1997)Reliability of roentgenogram evaluation of pedicle screw position Spine 22 1249-1252