Using the International 10-20 EEG System for Positioning of Transcranial Magnetic Stimulation

被引:0
作者
Uwe Herwig
Peyman Satrapi
Carlos Schönfeldt-Lecuona
机构
来源
Brain Topography | 2003年 / 16卷
关键词
International 10-20 EEG system; Cortex anatomy; Stereotaxic neuronavigation; Transcranial magnetic stimulation;
D O I
暂无
中图分类号
学科分类号
摘要
Background: The International 10-20 system for EEG electrode placement is increasingly applied for the positioning of transcranial magnetic stimulation (TMS) in cognitive neuroscience and in psychiatric treatment studies. The crucial issue in TMS studies remains the reliable positioning of the coil above the skull for targeting a desired cortex region. In order to asses the precision of the 10-20 system for this purpose, we tested its projections onto the underlying cortex by using neuronavigation. Methods: In 21 subjects, the 10-20 positions F3, F4, T3, TP3, and P3, as determined by a 10-20 positioning cap, were targeted stereotactically. The corresponding individual anatomical sites were identified in the Talairach atlas. Results: The main targeted regions were: for F3 Brodmann areas (BA) 8/9 within the dorsolateral prefrontal cortex, for T3 BA 22/42 on the superior temporal gyrus, for TP3 BA 40/39 in the area of the supramarginal and angular gyrus, and for P3 BA 7/40 on the inferior parietal lobe. However, in about 10% of the measurements adjacent and possibly functionally distinct BAs were reached. The ranges were mainly below 20 mm. Conclusion: Using the 10-20 system for TMS positioning is applicable at low cost and may reach desired cortex regions reliably on a larger scale level. For finer grained positioning, possible interindividual differences, and therefore the application of neuroimaging based methods, are to be considered.
引用
收藏
页码:95 / 99
页数:4
相关论文
共 124 条
  • [1] Barnett G.H.(1993)Registration of EEG electrodes with three-dimensional neuroimaging using a frameless, armless stereotactic wand Stereotact. Funct. Neurosurg. 61 32-38
  • [2] Kormos D.W.(1997)Stimulation over the human supplementary motor area interferes with the organization of future elements in complex motor sequences Brain 120 1587-1602
  • [3] Steiner C.P.(2000)Individual cortical current density reconstructions of the semantic N400 effect: using a generalized minimum norm model with different constraints (L1 and L2 norm) Human Brain Mapping 11 178-192
  • [4] Morris H.(2001)Transcranial magnetic stimulation in therapy studies: examination of the reliability of coil positioning by neuronavigation Biol. Psychiatry 50 58-61
  • [5] Gerloff C.(2001)The navigation of transcranial magnetic stimulation Psychiatry Res: Neuroimaging 108 123-131
  • [6] Corwell B.(2002)Spatial correspondence of neuronavigated transcranial magnetic stimulation and functional neuroimaging Clinical Neurophysiology 113 42-48
  • [7] Chen R.(2000)Transcranial magnetic stimulation and auditory hallucinations in schizophrenia Lancet 25 1073-1075
  • [8] Hallett M.(1987)Cerebral location of international 10-20 system electrode placement Electroencephalogr. Clin. Neurophysiol. 66 376-382
  • [9] Cohen L.G.(1958)The ten-twenty electrode system of the International Federation Electroencephalogr. Clin. Neurophysiol. 10 370-375
  • [10] Haan H.(2000)Spatial working memory performance after high-frequency repetitive transcranial magnetic stimulation of the left and right posterior parietal cortex in humans Neurosci. Lett. 287 68-70